ION EEM Installation Error in Windows x64

Goals and Symptoms

The EEM installer does not run in Windows Server 2008 R2 x64 or Windows 7 x64, the setup log contains the following message:
Beginning setup log 2-6-2010 14:19:08
   ION EEM 3.95.1028 build

   Setup Aborted: Windows Server 2008 or greater is inadequate for this
   installation.

text

Facts and Changes

EEM 3.95, Installation, Operating System, Windows 2008, 64 bits

Causes and Fixes

In order to instruct the installer to not check for the OS version and other prerequisites open a Command Line, navigate to the folder where the installation files live and type the following command:

setup.exe /z"skipprereqs"

This will allow you to continue the installation process. It's important to note that ION EEM is not officially supported neither in Windows 2008 R2 x64.or Windows 7 x64.


Legacy KB System (APS) Data: RESL201417 V2.0, Originally authored by GeVe on 02/23/2010, Last Edited by GeVe on 02/24/2010