  • Main
    range
    TeSys
    product name
    TeSys B
    product or component type
    Contactor
    device short name
    LC1BP
    contactor application
    Motor-heating-lighting
    utilisation category
    AC-1
    control circuit type
    AC
    coil type
    Standard
    poles description
    4P
    pole contact composition
    4 NO
    [Ie] rated operational current
    2000 A (at <40 °C) AC AC-1 for power circuit
    auxiliary contact composition
    4 NO
    [Uc] control circuit voltage
    240 V AC 50...400 Hz
    Complementary
    protective cover
    With
    auxiliary contacts type
    type instantaneous 4 NO
    control circuit voltage limits
    Operational: 0.85...1.1 Uc
    Drop-out: 0.35...0.5 Uc
    [Ui] rated insulation voltage
    1000 V - for power circuit conforming to IEC 60158-1
    1000 V - for power circuit conforming to IEC 60947-4
    1500 V - for power circuit conforming to VDE 0110 group C
    connections - terminals
    Power circuit: bars 3 x - busbar cross section: 100 x 5 mm
    tightening torque
    Power circuit: 35 N.m - on bars
    [Ue] rated operational voltage
    Power circuit: <= 1000 V AC 50/60 Hz
    [Ith] conventional free air thermal current
    2000 A (at 40 °C) for power circuit
    Irms rated making capacity
    15000 A at 1000 V AC for power circuit conforming to IEC 60158-1
    15000 A at 1000 V AC for power circuit conforming to IEC 60947-4
    rated breaking capacity
    12000 A at 500 V for power circuit conforming to IEC 60158-1
    12000 A at 500 V for power circuit conforming to IEC 60947-4
    15000 A at 440 V for power circuit conforming to IEC 60158-1
    15000 A at 440 V for power circuit conforming to IEC 60947-4
    5000 A at 1000 V for power circuit conforming to IEC 60158-1
    5000 A at 1000 V for power circuit conforming to IEC 60947-4
    9000 A at 660...690 V for power circuit conforming to IEC 60158-1
    9000 A at 660...690 V for power circuit conforming to IEC 60947-4
    associated fuse rating
    1600 A aM at <= 440 V for power circuit
    2000 A gI at <= 440 V for power circuit
    average impedance
    0.13 mOhm - Ith 2000 A 50 Hz for power circuit
    power dissipation per pole
    520 W AC-1 - Ith 2000 A
    inrush power in VA
    1600 VA
    hold-in power consumption in VA
    47 VA
    operating time
    100...150 ms closing
    20...40 ms opening
    mechanical durability
    1200000 cycles
    maximum operating rate
    120 cyc/h 55 °C
    rated operational power in VA
    2000 VA at 110…127 V AC-1 - electrical durability: 1000000 cycles - for control circuit
    3500 VA at 500 V AC-1 - electrical durability: 1000000 cycles - for control circuit
    4000 VA at 220 V AC-1 - electrical durability: 1000000 cycles - for control circuit
    4000 VA at 380 V AC-1 - electrical durability: 1000000 cycles - for control circuit
    4000 VA at 415…440 V AC-1 - electrical durability: 1000000 cycles - for control circuit
    rated operational power in W
    200 W at 500 V AC - electrical durability: 1000000 cycles - for control circuit
    230 W at 440 V AC - electrical durability: 1000000 cycles - for control circuit
    250 W at 110 V AC - electrical durability: 1000000 cycles - for control circuit
    250 W at 220 V AC - electrical durability: 1000000 cycles - for control circuit
    height
    500 mm
    width
    475 mm
    depth
    1095 mm
    net weight
    41 kg
    Environment
    standards
    IEC 60158-1
    BS 5424
    NF C 63-110
    VDE 0660
    IEC 60947-4
    product certifications
    BV
    CSA
    RINA
    protective treatment
    TC
    TH
    ambient air temperature for operation
    -5…55 °C
    ambient air temperature for storage
    -60…80 °C
    operating altitude
    3000 m without
    Offer Sustainability
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • English6
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    prp.document.label.format pdf
    Size 111.5 MB
    Date 7/12/19
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    CAD
    Format
    Size
    Date
    Add to My Documents
    TeSys B contactor 4P 2000A 240V AC (Version 1.0)
    Files in document
    pdf
    4.7 MB
    stp
    18.9 MB
    prp.document.label.format zip
    Size 23.7 MB
    Date 10/2/18
    Files in document
    pdf
    4.7 MB
    stp
    18.9 MB
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 7.7 MB
    Date 6/1/16
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    LC1BP34U40 : bar-mounted contactor - TeSys LC1-BP - 4P - AC-1 1000 V 2000 A - coil 240 VAC
    Description
    bar-mounted contactor - TeSys LC1-BP - 4P - AC-1 1000 V 2000 A - coil 240 VAC
    prp.document.label.format pdf
    Size 195.3 KB
    Date 4/9/20
    Description
    bar-mounted contactor - TeSys LC1-BP - 4P - AC-1 1000 V 2000 A - coil 240 VAC
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    LC1BP34U40 : bar-mounted contactor - TeSys LC1-BP - 4P - AC-1 1000 V 2000 A - coil 240 VAC
    Description
    bar-mounted contactor - TeSys LC1-BP - 4P - AC-1 1000 V 2000 A - coil 240 VAC
    prp.document.label.format pdf
    Size 195.3 KB
    Date 4/9/20
    Description
    bar-mounted contactor - TeSys LC1-BP - 4P - AC-1 1000 V 2000 A - coil 240 VAC
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    LC1BP34U40 : bar-mounted contactor - TeSys LC1-BP - 4P - AC-1 1000 V 2000 A - coil 240 VAC
    Description
    bar-mounted contactor - TeSys LC1-BP - 4P - AC-1 1000 V 2000 A - coil 240 VAC
    prp.document.label.format pdf
    Size 195.3 KB
    Date 4/9/20
    Description
    bar-mounted contactor - TeSys LC1-BP - 4P - AC-1 1000 V 2000 A - coil 240 VAC
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /