Issue
How to find Retrieve Security Information from SQL Server
Product Line
Struxureware Power Monitoring 7.0.x
Power Monitoring Expert 7.2.x
Power Monitoring Expert 8.x
Power Monitoring Expert 9.x
Power Monitoring Expert 2020
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023
Power Monitoring Expert 2024
Environment
SQL Server 2005, SQL Server 2008 R 2, SQL Server 2012, SQL Server 2014, SQL Server 2016, SQL Server 2017, SQL Server 2019, SQL Server 2022
Cause
SQL Server needs to be configured with an account with the correct permissions.
Resolution
Warning: Irreparable database damage can occur. This procedure should only be performed by users familiar with SQL Server Management Studio. Databases should be backed up prior to performing this procedure.
Navigate to SQL Server Management Studio. Login security information can be found underneath Security -> Logins -> Right click on user -> Select Properties -> Select Server Roles
To retrieve the security information of current SQL Server installation, log into SQL Server Management Studio and run the attached SQL script (SQL_Security_Scripts.sql).
Alternatively, execute the query(s) below :
Script to find server level logins and role assigned:SELECT
a.
name
as
LoginName,a.type_desc
AS
LoginType, a.default_database_name
AS
DefaultDBName,
CASE
WHEN
b.sysadmin = 1
THEN
'sysadmin'
WHEN
b.securityadmin=1
THEN
'securityadmin'
WHEN
b.serveradmin=1
THEN
'serveradmin'
WHEN
b.setupadmin=1
THEN
'setupadmin'
WHEN
b.processadmin=1
THEN
'processadmin'
WHEN
b.diskadmin=1
THEN
'diskadmin'
WHEN
b.dbcreator=1
THEN
'dbcreator'
WHEN
b.bulkadmin=1
THEN
'bulkadmin'
ELSE
'Public'
END
AS
'ServerRole'
FROM
sys.server_principals a
JOIN
master..syslogins b
ON
a.sid=b.sid
WHERE
a.type <>
'R'
AND
a.
name
NOT
LIKE
'##%'
Script to find database users and roles assigned:DECLARE
@DBuser_sql
VARCHAR
(4000)
DECLARE
@DBuser_table
TABLE
(DBName
VARCHAR
(200), UserName
VARCHAR
(250), LoginType
VARCHAR
(500), AssociatedRole
VARCHAR
(200))
SET
@DBuser_sql=
'SELECT '
'?'
' AS DBName,a.name AS Name,a.type_desc AS LoginType,USER_NAME(b.role_principal_id) AS AssociatedRole FROM ?.sys.database_principals a
LEFT OUTER JOIN ?.sys.database_role_members b ON a.principal_id=b.member_principal_id
WHERE a.sid NOT IN (0x01,0x00) AND a.sid IS NOT NULL AND a.type NOT IN ('
'C'
') AND a.is_fixed_role <> 1 AND a.name NOT LIKE '
'##%'
' AND '
'?'
' NOT IN ('
'master'
','
'msdb'
','
'model'
','
'tempdb'
') ORDER BY Name'
INSERT
@DBuser_table
EXEC
sp_MSforeachdb @command1=@dbuser_sql
SELECT
*
FROM
@DBuser_table
ORDER
BY
DBName
Script to find Object level permission for user databases:DECLARE
@Obj_sql
VARCHAR
(2000)
DECLARE
@Obj_table
TABLE
(DBName
VARCHAR
(200), UserName
VARCHAR
(250), ObjectName
VARCHAR
(500), Permission
VARCHAR
(200))
SET
@Obj_sql=
'select '
'?'
' as DBName,U.name as username, O.name as object, permission_name as permission from ?.sys.database_permissions
join ?.sys.sysusers U on grantee_principal_id = uid join ?.sys.sysobjects O on major_id = id WHERE '
'?'
' NOT IN ('
'master'
','
'msdb'
','
'model'
','
'tempdb'
') order by U.name '
INSERT
@Obj_table
EXEC
sp_msforeachdb @command1=@Obj_sql
SELECT
*
FROM
@Obj_table
Yayımlanma amacı:Schneider Electric Turkey