This document contains the Spare Parts List for ACSC1XX units.
Product line:
ACSC100, ACSC101.
Environment:
All serial numbers.
Cause:
Install, Repair.
Resolution:
Please contact Cooling Tech Support to confirm the part numbers before quoting as some may have changed. 888-695-6500 Option 2, Option 2, Option 2
DESCRIPTION | APC PN# | QTY | Manufacturing # |
***USC Special Orders | QAIRDIST-MISC | ||
ASSY CORR BD TWF06 ROHS | 0P9028A | 1 | |
BAYING BRACKET NETSHELTER SX | 870-11538 | 2 | |
BAYING BRACKET SCREW M5 X 12 FLT UCUT PHIL M5 X 12 BLK (for baying kit) | 803-5006A | 2 | |
BOX ASSY for DUCT KIT ACSC 5KW | 0M-61250 | 1 | |
CABLE ASSY RELATIVE HUMIDITY SENSOR | W0N-0297[RH1] front | 1 | |
CABLE ASSY RELATIVE HUMIDITY SENSOR | W0N-0865[RH2] Rear | 1 | |
CABLE ASSY Temperature Humidity Sensor | AP9335TH | ||
CABLE ASSY Temperature Sensor | AP9335T | ||
CABLE ASSY TEMPERATURE SENSORS | 0J-0W3163A {8FT.EN_US} | ||
CABLE ASSY TEMPERATURE SENSORS (Rack Inlet) | 0J-0W2818A {13FT.EN_US} | 1 | |
CAP MTL PPR 400V 5% 40UF RD (compressor) | W234-1406 (234-1406) | ||
CAP MTL PPR 450V 55UF WITH TAP (compressor) | W234-0556 (234-0556) | ||
CASTER STEEL 2" RIGID DARKSTAR (rear) | 870-6620 | 2 | |
CASTER SWIVEL 650 LBS 2.8IN OH (front) | 870-71046 | 2 | |
Ceiling Tile Adapter 24" - Spare Part | W870-80333 | ||
Ceiling Tile Adapter 600mm - Spare Part | W870-80336 | ||
COMP Assy, SC, ROTARY 208-230/1/60 (Toshiba conversion kit) | W0H-0170 | ||
COMP Assy, SC, ROTARY 220-240/1/50 (Toshiba conversion kit) | W0H-0171 | ||
COMP, ROTARY 208-230/1/60, SC, TOSHIBA - SPARE PART | W875-3825 | 1 | |
COMP, ROTARY 220-240/1/50 SC, TOSHIBA - SPARE PART | W875-3826 | 1 | |
Compressor Wiring Harness (FSB ) | W0W3418 | ||
CONDENSATE PUMP DUAL ASSY W/HOSES (Dual Condensate Pump) | 0N-0993SE | ||
CONDENSATE PUMP FITTING BARBED (Y barb fittings) .13"X.13"X.13" (inlet) | 875-4367 (for Dual Condensate Pump) | ||
CONDENSATE PUMP FITTING BARBED (Y barb fittings) .19"X.19"X.19" (outlet) | 875-4368 (for Dual Condensate Pump) | ||
CONDENSATE PUMP TUBE PVC .125IN ID .250IN OD (18" long PVC TUBE for 875-4367) | 875-0481 (for Dual Condensate Pump) | ||
CONDENSATE PUMP TUBE PVC .188IN ID .313IN OD (18" long PVC TUBE for 875-4368) | 875-0857B (for Dual Condensate Pump) | ||
CONDENSATE PUMP TUBE PVC .625IN ID .750OD (2.3 FEET (700 MM) LONG) | 875-0482 (for Dual Condensate Pump) | ||
CONDENSATE PUMP WIRE ASSY CP JUMPER (for activation without the water sensor kit) | 0W3133 | ||
CONDENSATE PUMP WITH Float - Spare Part (Dual voltage 120v/208v) | 0J-0011 | 1 |
|
CONDENSER COIL ASSY SC5 | 0M-61169 | 1 | |
Condenser Fan 200mm Mixed Flow (INDIVIDUAL FAN) | W490-0079 | 3 | |
CONNECTOR SET 17KW IR SPARES for Jumper | W0H-0127 | ||
CONVERSION TO TOSHIBA COMP KIT , SC, 50HZ - SPARE PART | W0H-0171 | ||
DC RECTIFIER, 500 WATT, 54VDC, WIDE INPUT, FULL SIGNALS, BLACK | W1TWF0500H54B | 2 | |
DIVIDER-'A' DUCT KIT ACSC 5KW 48ECT BC NKRAFT | 871-3527 | 3 | |
DIVIDER-'B' DUCT KIT ACSC 5KW 48ECT BC NKRAFT | 871-3528 | 2 | |
Door Key - Spare Part | W870-8135 | ||
DRIVER BIT COMBO TORX T20/T30 (tool kit) | 815-0001 | 1 | |
DUCTING KIT 24 INCH IR5 | 0M-61152 (0M-61250) | 1 | |
ELECTRONIC EXPANSION VALVE Harness (HBGP harness ) | 0W4409 | ||
ELECTRONIC EXPANSION VALVE, 3/8" ODF (HGBP) | 875-4275A | 1 | |
EVAPORATOR FAN MODULE ASSY - 17 KW IR | W0M-61005 | 3 | |
FAN 12VDC 60X25MM 25CFM ROHS (individual fan) | 490-0030 | 1 | |
FAN FUSE NTC COMPLETE 818 PCB CRAC | 0P2390 | 3 | |
FILTER - NON -WASHABLE PRINTING IR SERIES 2 IN THK | W0B1657 | ||
FILTER - WASHABLE IR SERIES 1/2" THK - SPARE PART | W875-2010 | ||
FITTING 1/8" BARB 10-32 | 870-80064 | ||
FITTING 1/8" BARB TEE (for air differential pressure switch) | 870-80066 | 1 | |
FLOAT SWITCH BULK MOUNT 4" MNL | 0N-0279A | 2 | |
FLOAT SWITCH, BULKHEAD MOUNT (single float) | 540-0205 | 1 | |
FILTER-DRIER 3/8"ODF SOLDER | w875-2085 | 1 | |
FM TOOL KIT SUB ASSY | 0M-5383 | ||
FOOT LEVELING M10 X 51 L X 28 OD NYLOK | 825-0035C | 2 | |
Front Door Assembly - Spare Part | W0M-61085 | 1 | |
GROMMET RUBBER 1 1/2"ID X 1 3/4"GD X 1/8"GW (for power cable at the bottom) | 827-0219 | 2 | |
HI PRESS SW; OPENS 550PSIG CLOSES 400PSIG | w541-0087 | 1 | 20PS11-0003 |
InRow RC/SC Filter 1/2" Washable - Spare Part (default) | W875-2010 | 1 | |
JUMPER PHASE SELECT | 0W3268 | ||
LATCH FLUSH SLAM W/ TUMBLER #333 (for side door panels) | 840-0192-333 | 2 | |
Leak Sensor - 20 ft (6.1 m) (ships with orange sensor [AP9326] & black Cat5e cable) | AP9325 | ||
LOCTITE 554 - REFRIGERANT THREAD SEALING | 690-0144 | 0 | |
NMC with CAN controller (Embedded) | WAP9517CAN | 32 | |
PCB ASSY 5KDX BOARD SET (MB,WC,XA,DP) | W0P2476 | 1 | |
PCB ASSY, Motherboard W/SIMM AND Mini-Rhodes | W0P2370 | ||
PCB CRAC 2X DP SIMM 805 COMPLETE (differential Pressure Switch) | W0P2354A | 1 | |
PCB CRAC MB COMPLETE 801 (motherboard) | W0P2340 | 1 | |
PCB XA SIMM 879 Complete Assy - Spare Part (XA card) | W0P2342 | ||
PowerView - Spare Part | WAP9233 | 1 | |
PRESSURE TRANSDUCER 2CP5 | 875-3400 | 2 | |
PWR Backplane 802 PCB CRAC - Spare Part | W0P2341 | 1 | |
PWR CORD IEC-C19 FEM TO L6-20P LCDI | 960-0126 | 1 | |
Pwr Cord, 16A, 200-240V, C19 to L6-20 | AP9871 | ||
REAR DOOR ASSY - 17 KW | 0M-61004B | 1 | |
Relay Coil 250V 25A DPNO 24DC [compressor relay] | W450-0024 | ||
RELAY DPDT 120VAC 8A PC MOUNT | 450-0302 | 1 | |
RELAY PWR SPDT 16A/250V 20A/125V NO 24V | 450-0012A | 1 | |
SIDE PANEL ASSY - IR SERIES | W0M-61031 | 4 | |
STRAIN RELIEF HEYCO SR 7N-2 (for control box) | 652-07N2 | 3 | |
TELECOUPLNG 8P8C RJ45 STRAIGHT | 750-0034 | 1 | |
TELECOUPLNG 8P8C RJ45 STRAIGHT (ethernet telecoupler) | W750-0034 | ||
TERMINATOR ROHS EXT BATT COMM BOARD (for communication board) | 0W04161A | 1 | |
Thermistor/Probe EMU Cable ASSY - Spare Part (13FT PURPLE) | W0W2818 (0W2818) | 1 | |
TUBE 6 FT 10" DIA FLEX DUCT | 875-0922A | 3 | |
TUBE PVC .125IN ID .250IN OD | 875-0481 | ||
TUBE PVC .188IN ID .313IN OD | 875-0857B |
| |
TUBING PVC CLEAR 0.25ID | 660-7001D | ||
TXV VALVE 3/8"ODM X 5/8" ODF R410A 1.5 TON | w875-1002 | 1 | BBIZE-1.5-ZCP180BP5 |
Wire Assembly Base | W0W3287 | ||
WIRE ASSY SC5 COMPRESSOR (for FSB AT0093GB001) | W0W3418 | 1 | |
WIRE ASSY SC5 LOWER PWR FEED MB | 0W3288A | 1 | |
WIRE ASSY SC5 PRESSURE SENSING | 0W3293B | 1 | |
WIRE ASSY SC5 PSU/CP PWR/48VDC OUT | 0W3290A | 1 | |
WIRE ASSY SC5 UPPER PWR FEED MB | 0W3291A | 1 | |
WIRE CLIP - BLACK AP9335TH (holds sensor cables) | 870-13220 | 4 | |
WIRE TIE 4X.1X.04 BLK | 820-0247-010 | 2 | |
XFMR ISOLATION1:1.3 MAX253 | 430-0244 | 1 | |
1U Airflow Management Blanking Panel Kit (Qty 2) Black | AR8108BLK | ||
1U 19" Black Modular Toolless Airflow Management Blanking Panel - Qty 10 | AR8136BLK | ||
1U 19" Black Modular Toolless Airflow Management Blanking Panel - Qty 200 | AR8136BLK200 | ||
Released for:Schneider Electric UK

