iC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 V
Show more characteristics-
Characteristics
Main circuit breaker application Distributionrange Acti 9product name Acti 9 iC60 RCBOproduct or component type Residual current breaker with overcurrent protection (RCBO)device short name IC60N RCBOpoles description 1P + N[In] rated current 6 A at 50 °Cearthing system TNcurve code Cearth-leakage sensitivity 30 mAbreaking capacity 6000 A Icn at 240 V AC 50/60 HzComplementary neutral position Leftnumber of protected poles 1device location in system Outgoernetwork type ACnetwork frequency 50/60 Hz[Ue] rated operational voltage 240 V AC 50/60 Hztrip unit technology Thermal-magneticresidual current tripping technology Voltage dependentearth-leakage protection time delay Instantaneousearth-leakage protection class Type A[Icw] rated short-time withstand current Icw: 250 A during 8/20 µs impulse withstand[Ics] rated service breaking capacity 6000 A at 240 V AC 50/60 Hzlimitation class 3[Ui] rated insulation voltage 400 V AC 50/60 Hz[Uimp] rated impulse withstand voltage 4 kVsuitability for isolation Yescontact position indicator Yescontrol type Togglelocal signalling ON/OFF indicationmounting mode Clip-onmounting support DIN railcomb busbar and distribution block compatibility NO9 mm pitches 2height 110 mmwidth 18 mmdepth 77.5 mmnet weight 205 gcolour Whitemechanical durability 20000 cycleselectrical durability 5000 cyclesprovision for padlocking Padlockable with padlock Ø 4 mmlocking options description ON/OFF locking facilitiesconnections - terminals Screw clamp terminal (top) 1…25 mm² rigid without cable endScrew clamp terminal (top) 1…16 mm² flexibleScrew clamp terminal (bottom) 1…16 mm² rigid without cable endScrew clamp terminal (bottom) 1…10 mm² flexiblewire stripping length Power circuit: 13 mm for bottom connectionPower circuit: 14 mm for top connectiontightening torque Power circuit: 3.5 N.m topPower circuit: 2 N.m bottomearth-leakage protection IntegratedEnvironment standards IEC 61009-1IEC 61009-2-2AS/NZS 61009.1IP degree of protection IP20tropicalisation 2relative humidity 95 % at 55 °Cambient air temperature for operation -15…60 °Cambient air temperature for storage -40…85 °COffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your informationEnvironmental Disclosure Circularity Profile Contractual warranty Warranty 18 months -
View more
Documents
Language- English14
CatalogueFormatSizeAdd to My DocumentsReady to install Distribution and Control products - Acti 9 (Version 1.0)DescriptionSchneider Electric’s Ready to Install offer brings together the company’s range of solutions for the distribution, protection, control and management of electrical systems. As a global specialist in energy management, Schneider Electric offers integrated solutions making energy safer, more reliable, efficient and productive.Size pdfSize 38.3 MBDate 02/02/15DescriptionSchneider Electric’s Ready to Install offer brings together the company’s range of solutions for the distribution, protection, control and management of electrical systems. As a global specialist in energy management, Schneider Electric offers integrated solutions making energy safer, more reliable, efficient and productive.Instruction sheetFormatSizeAdd to My DocumentsCADFormatSizeAdd to My DocumentsCAD file (on TraceParts) for A9D61806: iC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 V (Version 2.0)DescriptionYou will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.CAD file (on TraceParts) for A9D61806: iC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 V (Version 2.0)DescriptionYou will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.iC60N-H RCBO 1P+N 6A…45A 30/100mA with overcurrent protectionFiles in documentSize zipSize 2.9 MBDate 06/07/12Files in documentiC60N-H RCBO 1P+N 6A…45A 30/100mA with overcurrent protectionFiles in documentSize zipSize 606.5 KBDate 06/07/12Files in documentCertificateFormatSizeAdd to My DocumentsCB Certificate SE-87253 for iC60N-H RCBO according to IEC 61009-1:2010 +A1 +A2 and IEC 61009-2-2:1991 (Version 1.0)Size pdfSize 842.9 KBDate 09/06/17Declaration of conformityFormatSizeAdd to My DocumentsEnd of Life InformationFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsiC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 VDescriptioniC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 VSize pdfSize 195.3 KBDate 16/12/19DescriptioniC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 VProduct Environmental ProfileFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My DocumentsiC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 VDescriptioniC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 VSize pdfSize 195.3 KBDate 16/12/19DescriptioniC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 VChina RoHS declarationFormatSizeAdd to My DocumentsiC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 VDescriptioniC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 VSize pdfSize 195.3 KBDate 16/12/19DescriptioniC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 V -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.