iC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 V

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    circuit breaker application
    Distribution
    range
    Acti 9
    product name
    Acti 9 iC60 RCBO
    product or component type
    Residual current breaker with overcurrent protection (RCBO)
    device short name
    IC60N RCBO
    poles description
    1P + N
    [In] rated current
    6 A at 50 °C
    earthing system
    TN
    curve code
    C
    earth-leakage sensitivity
    30 mA
    breaking capacity
    6000 A Icn at 240 V AC 50/60 Hz
    Complementary
    neutral position
    Left
    number of protected poles
    1
    device location in system
    Outgoer
    network type
    AC
    network frequency
    50/60 Hz
    [Ue] rated operational voltage
    240 V AC 50/60 Hz
    trip unit technology
    Thermal-magnetic
    residual current tripping technology
    Voltage dependent
    earth-leakage protection time delay
    Instantaneous
    earth-leakage protection class
    Type A
    [Icw] rated short-time withstand current
    Icw: 250 A during 8/20 µs impulse withstand
    [Ics] rated service breaking capacity
    6000 A at 240 V AC 50/60 Hz
    limitation class
    3
    [Ui] rated insulation voltage
    400 V AC 50/60 Hz
    [Uimp] rated impulse withstand voltage
    4 kV
    suitability for isolation
    Yes
    contact position indicator
    Yes
    control type
    Toggle
    local signalling
    ON/OFF indication
    mounting mode
    Clip-on
    mounting support
    DIN rail
    comb busbar and distribution block compatibility
    NO
    9 mm pitches
    2
    height
    110 mm
    width
    18 mm
    depth
    77.5 mm
    net weight
    205 g
    colour
    White
    mechanical durability
    20000 cycles
    electrical durability
    5000 cycles
    provision for padlocking
    Padlockable with padlock Ø 4 mm
    locking options description
    ON/OFF locking facilities
    connections - terminals
    Screw clamp terminal (top) 1…25 mm² rigid without cable end
    Screw clamp terminal (top) 1…16 mm² flexible
    Screw clamp terminal (bottom) 1…16 mm² rigid without cable end
    Screw clamp terminal (bottom) 1…10 mm² flexible
    wire stripping length
    Power circuit: 13 mm for bottom connection
    Power circuit: 14 mm for top connection
    tightening torque
    Power circuit: 3.5 N.m top
    Power circuit: 2 N.m bottom
    earth-leakage protection
    Integrated
    Environment
    standards
    IEC 61009-1
    IEC 61009-2-2
    AS/NZS 61009.1
    IP degree of protection
    IP20
    tropicalisation
    2
    relative humidity
    95 % at 55 °C
    ambient air temperature for operation
    -15…60 °C
    ambient air temperature for storage
    -40…85 °C
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    Circularity Profile
    Contractual warranty
    Warranty
    18 months
  • Documents

    Language
    • English
    Instruction sheet
    Date
    Size
    Add to My Documents
    iC60N - RCBO instruction sheet (Version 01)
    Date 12/10/12
    Size 219.1 KB
    CAD
    Date
    Size
    Add to My Documents
    CAD file (on TraceParts) for A9D61806: iC60N - earth leakage circuit breaker - 1P + N - C curve - 6 A - 30 mA - 240 V (Version 2.0)
    iC60N-H RCBO 1P+N 6A…45A 30/100mA with overcurrent protection
    iC60N-H RCBO 1P+N 6A…45A 30/100mA with overcurrent protection
    Certificate
    Date
    Size
    Add to My Documents
    CB Test Certificate (Version 1.0)
    Date 09/06/17
    Size 842.5 KB
    CB Certificate SE-87253 for iC60N-H RCBO according to IEC 61009-1:2010 +A1 +A2 and IEC 61009-2-2:1991 (Version 1.0)
    Certificate of Approval (Version 1.0)
    Date 15/08/17
    Size 217.9 KB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    EU Declaration FD16040504D for iC60N-H RCBO (Version 5.0)
    End of Life Information
    Date
    Size
    Add to My Documents
    iC60 RCBO - EoLi (Version 1.1)
    Date 07/07/17
    Size 72 KB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    iC 60 RCBO - PEP (Version 2.0)
    Date 07/07/17
    Size 212.1 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    RoHs China Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /