United Kingdom
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Galaxy VX
Schneider Eletric GVX1250K1000HS Picture

GVX1250K1000HS

Schneider Eletric GVX1250K1000HS Picture
GVX1250K1000HS

Galaxy VX 1000kVA N+1 Redundant UPS 400V, Start up 5x8

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Overview
    Description
    Highly efficient, scalable, 3-phase power protection with flexible operating modes and ECOnversion™ for large facilities, data centers, and business critical applications.
    Model Name
    Galaxy VX 1000kVA N+1 Redundant UPS 400V, Start up 5x8
    Includes
    Installation guide , Start-Up Service
    Standard Lead Time
    Special Order - Call for Quoted Lead Times
    Product Distribution
    Afghanistan , Albania , Algeria , Andorra , Angola , Armenia , Australia , Austria , Azerbaijan , Bahrain , Bangladesh , Belarus , Belgium , Benin , Bhutan , Bosnia And Herzegovina , Botswana , Brazil , Brunei Darussalam , Bulgaria , Burkina Faso , Burundi , Cambodia , Cameroon , Canada , Central African Republic , Chad , China , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Cook Islands , Cote D'Ivoire , Croatia , Cyprus , Czech Republic , Denmark , Djibouti , East Timor , Egypt , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Fiji , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Guadeloupe , Guinea , French Guiana , Hong Kong , Hungary , Iceland , India , Indonesia , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Japan , Jordan , Kazakhstan , Kenya , KOREA, REPUBLIC OF , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Malaysia , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Myanmar , Namibia , Nepal , Netherlands , New Zealand , Niger , Nigeria , Norway , Oman , Pakistan , Papua New Guinea , Philippines , Poland , Portugal , Qatar , Reunion , Romania , Russian Federation , Rwanda , Saudi Arabia , Senegal , Sierra Leone , Singapore , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sri Lanka , Sudan , Suriname , Sweden , Switzerland , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Thailand , Togo , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , United States , Uzbekistan , Viet Nam , Western Sahara , Yemen , Zambia , Zimbabwe
    Output
    Output Power Capacity
    1.0 MW / 1.0 MVA
    Max Configurable Power (Watts)
    1.0 MW / 1.0 MVA
    Nominal Output Voltage
    400 3PH
    Output Frequency (sync to mains)
    50 Hz , 60 Hz
    Other Output Voltages
    380, 415, 440V
    Crest Factor
    3 with THC <5%
    Double Conversion Online
    Waveform Type
    Sine wave
    Output Voltage THD
    < 2% linear load and <3% non-linear load
    Overload Operation
    150% for 1 minute 125% for 10 minutes
    Input
    Nominal Input Voltage
    400 3PH
    Input Frequency
    40 - 70 Hz
    Other Input Voltages
    380 , 415 , 440
    Maximum Input Current
    1702 A
    Maximum Short Circuit Withstand (Icw)
    100.0
    Input Total Harmonic Distortion
    Less than 3% for full load
    Batteries & Runtime
    Battery Type
    No internal battery - uses external battery system
    Nominal Battery Voltage
    480V
    End of Discharge Battery Voltage
    384 Vdc
    Communications & Management
    Available SmartSlot™ Interface Quantity
    2
    Control panel
    7" Touch Screen Display
    Audible Alarm
    Audible and visible alarms prioritized by severity
    Physical
    Maximum Height
    1970.0 mm
    Maximum Width
    4500.0 mm
    Maximum Depth
    900.0 mm
    Net Weight
    3500.0 kg
    Shipping Weight
    4680.0 kg
    Shipping Height
    2150.0 mm
    Shipping Width
    5390.0 mm
    Shipping Depth
    1060.0 mm
    Color
    White
    Environmental
    Operating Environment
    0 - 40 °C
    Operating Relative Humidity
    0 - 95 (non-condensing) %
    Operating Elevation
    0-999.9 meters
    Storage Temperature
    -15 - 40 °C
    Storage Relative Humidity
    0 - 95 (non-condensing) %
    Storage Elevation
    0-15000 meters
    Audible noise at 1 meter from surface of unit
    69.500 dB
    Online Thermal Dissipation
    169513.000 BTU/hr
    Protection Class
    IP 20
    Conformance
    Approvals
    C-tick , CE , IEC 62040-1-1 , IEC 62040-2 , IEC 62040-3 , IEC 62040-4 , ISTA 2B , UL 1778 5th edition , cUL Listed
    Standard warranty
    1 year on-site repair or replace with factory authorized Start-Up
    Sustainable Offer Status
    RoHS
    Compliant
    REACH
    REACH: Contains No SVHCs
    Battery Directive
    Compliant
  • View more View less

    Documents

    Language
    • English17
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Galaxy VX 500 to 1500kVA 400V Brochure (Version 4)
    Files in document
    Description
    Features and benefits, ideal applications, and product specifications
    Size zip
    Size 5.6 MB
    Date 14/01/18
    Files in document
    Description
    Features and benefits, ideal applications, and product specifications
    User guide
    Format
    Size
    Date
    Add to My Documents
    Galaxy VX Modbus Register Map (Version 1)
    Description
    Galaxy VX Modbus Register Map
    Size pdf
    Size 133 KB
    Date 14/11/19
    Description
    Galaxy VX Modbus Register Map
    Galaxy VX UPS with 1000 kW IO Cabinet 400/480 V Installation (Version 4)
    Description
    Providing the certified electrician with information on how to install and connect the Galaxy VX UPS.
    Size pdf
    Size 22 MB
    Date 24/10/19
    Description
    Providing the certified electrician with information on how to install and connect the Galaxy VX UPS.
    Galaxy VX Operation Manual (Version 6)
    Description
    Contains information on operation, maintenance and troubleshooting for the users of the Galaxy VX system
    Size pdf
    Size 4.2 MB
    Date 18/06/18
    Description
    Contains information on operation, maintenance and troubleshooting for the users of the Galaxy VX system
    Galaxy VX Receiving and Unpacking (Version 2)
    Description
    Providing information on storage conditions and how to unpack the Galaxy VX cabinets and remove them from the pallet
    Size pdf
    Size 1.8 MB
    Date 08/06/17
    Description
    Providing information on storage conditions and how to unpack the Galaxy VX cabinets and remove them from the pallet
    CAD
    Format
    Size
    Date
    Add to My Documents
    Size zip
    Size 814.9 KB
    Date 01/01/19
    Description
    BIM Models, UPS, Galaxy VX
    Size zip
    Size 5.6 MB
    Date 11/11/18
    Files in document
    Description
    Galaxy VX, Mechanicals
    Size zip
    Size 889.4 KB
    Date 11/11/18
    Files in document
    pdf
    510 KB
    zip
    379.4 KB
    Description
    Galaxy VX, System Wiring
    GVX500-1000KHS-SD - Galaxy VX 500-625-750-1000kW UPS 1 Module w Batt One Line (Version 3)
    Files in document
    pdf
    560.9 KB
    zip
    204.6 KB
    Description
    Galaxy VX, System One Line
    Size zip
    Size 765.5 KB
    Date 30/05/18
    Files in document
    pdf
    560.9 KB
    zip
    204.6 KB
    Description
    Galaxy VX, System One Line
    Certificate
    Format
    Size
    Date
    Add to My Documents
    Galaxy VX Cmim Declaration of Conformity (Version 0)
    Description
    Cmim Declaration of Conformity
    Size pdf
    Size 101.6 KB
    Date 14/07/19
    Description
    Cmim Declaration of Conformity
    Galaxy VX EU Declaration of Conformity (Version 6)
    Description
    EU Declaration of Conformity
    Size pdf
    Size 97.2 KB
    Date 11/07/19
    Description
    EU Declaration of Conformity
    CB certificate for Galaxy VX 500KW/KVA modular up to 1500KW/KVA, incl. Power cabinet for modular build GVXP250KD (Version 0)
    Files in document
    pdf
    183.2 KB
    pdf
    183.2 KB
    Description
    CB Certificate for galaxy 500KW/KVA to 1500KW/KVA
    Size zip
    Size 366.4 KB
    Date 17/12/17
    Files in document
    pdf
    183.2 KB
    pdf
    183.2 KB
    Description
    CB Certificate for galaxy 500KW/KVA to 1500KW/KVA
    Galaxy VX OSHPD Pre-approval Letter (Version 1)
    Description
    OSHPD pre-approval letter
    Size pdf
    Size 3.6 MB
    Date 11/12/17
    Description
    OSHPD pre-approval letter
    GALAXY 500KW/KVA to GALAXY 1500KW/KVA UL1778 5th edition letter of Authorization (Version 0)
    Files in document
    pdf
    177.6 KB
    pdf
    177.6 KB
    Description
    UL Listing of GALAXY 500KW/KVA to GALAXY 1500KW/KVA 1778 5th edition
    Size zip
    Size 355.2 KB
    Date 15/10/17
    Files in document
    pdf
    177.6 KB
    pdf
    177.6 KB
    Description
    UL Listing of GALAXY 500KW/KVA to GALAXY 1500KW/KVA 1778 5th edition
    Galaxy VX 400 V Certificate of Origin (Version 1)
    Description
    Certificate of Origin
    Size pdf
    Size 73.9 KB
    Date 14/06/17
    Description
    Certificate of Origin
    Specification for tender
    Format
    Size
    Date
    Add to My Documents
    CSI 2004/1995 Galaxy VX 300kW Expandable to 1500kVA N+1 Internal Redundancy (400V) (Version 6)
    Files in document
    Description
    Guide specification that offer the ability for our customers to build their design standards around the 400V Galaxy VX 300 to 1500kW 3-phase UPS
    Size zip
    Size 330.9 KB
    Date 12/11/19
    Files in document
    Description
    Guide specification that offer the ability for our customers to build their design standards around the 400V Galaxy VX 300 to 1500kW 3-phase UPS
    Specification guide
    Format
    Size
    Date
    Add to My Documents
    Galaxy VX 380 V, 400 V, 415 V, and 440V Technical Specifications (Version 3)
    Description
    Contains technical data, facility planning, drawings, options. Go to https://www.productinfo.schneider-electric.com/portals/ui/galaxyvx_iec/ for digital manuals.
    Size pdf
    Size 3.4 MB
    Date 17/12/17
    Description
    Contains technical data, facility planning, drawings, options. Go to https://www.productinfo.schneider-electric.com/portals/ui/galaxyvx_iec/ for digital manuals.
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /