LC1BL31ED22
bar-mounted contactor - TeSys LC1-BL - 1 pole - AC-1 440V 800 A - coil 48V DC
Show more characteristics-
Characteristics
Main range TeSysproduct name TeSys Bproduct or component type Contactordevice short name LC1BLcontactor application Motor-heating-lightingutilisation category AC-1control circuit type DCcoil type Standardpoles description 1Ppole contact composition 1 NO[Ie] rated operational current 800 A (at <40 °C) AC AC-1 for power circuitauxiliary contact composition 2 NO + 2 NC[Uc] control circuit voltage 48 V DCComplementary control circuit voltage limits Drop-out: 0.3...0.5 UcOperational: 0.85...1.1 Uc[Ui] rated insulation voltage 1000 V - for power circuit conforming to IEC 60158-11000 V - for power circuit conforming to IEC 60947-41500 V - for power circuit conforming to VDE 0110 group Cmounting mode Fixedmounting support Bar support bracketNotched mounting railstightening torque Power circuit: 21 N.m - on bars[Ue] rated operational voltage Power circuit: <= 1000 V AC 50/60 Hz[Ith] conventional free air thermal current 800 A (at 40 °C) for power circuitIrms rated making capacity 10000 A at 1000 V AC for power circuit conforming to IEC 60158-110000 A at 1000 V AC for power circuit conforming to IEC 60947-4rated breaking capacity 10000 A at 440 V for power circuit conforming to IEC 60158-110000 A at 440 V for power circuit conforming to IEC 60947-44000 A at 1000 V for power circuit conforming to IEC 60158-14000 A at 1000 V for power circuit conforming to IEC 60947-48000 A at 660...690 V for power circuit conforming to IEC 60158-18000 A at 660...690 V for power circuit conforming to IEC 60947-49000 A at 500 V for power circuit conforming to IEC 60158-19000 A at 500 V for power circuit conforming to IEC 60947-4associated fuse rating 1000 A gI at <= 440 V for power circuit800 A aM at <= 440 V for power circuit800 A gI at <= 440 V for power circuitaverage impedance 0.18 mOhm - Ith 800 A 50 Hz for power circuitpower dissipation per pole 115 W AC-1 - Ith 800 Ainrush power in W 520 Whold-in power consumption in W 10 Woperating time 100...150 ms closing20...40 ms openingmechanical durability 1200000 cyclesmaximum operating rate 120 cyc/h 55 °Cterminals description ISO n°1 (13-14)NOheight 486 mmwidth 375 mmdepth 475 mmnet weight 32 kgEnvironment standards IEC 60158-1NF C 63-110VDE 0660IEC 60947-4BS 5424product certifications RINACSABVprotective treatment TCTHambient air temperature for operation -5…55 °Cambient air temperature for storage -60…80 °Coperating altitude 3000 m withoutContractual warranty Warranty 18 months -
View more
Documents
Language- English2
CatalogueFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 12/07/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter B10 Bar mounted contactors TeSys B (Version 6.0)DescriptionContactors with pre-defined composition : TeSys BContactors with variable composition : TeSys CV1B, CV3B, order formContactors for heating applications 3000 V : TeSys BSize pdfSize 3.4 MBDate 15/05/19DescriptionContactors with pre-defined composition : TeSys BContactors with variable composition : TeSys CV1B, CV3B, order formContactors for heating applications 3000 V : TeSys B -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.