View all
TeSys D

LC1D32F7
LC1D32F7
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 110 V AC coil
Show more characteristics-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Resistive loadMotor controlutilisation category AC-1AC-3AC-4poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 HzPower circuit: <= 300 V DC[Ie] rated operational current 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit50 A (at <60 °C) at <= 440 V AC AC-1 for power circuitmotor power kW 7.5 kW at 220...230 V AC 50/60 Hz (AC-3)15 kW at 380...400 V AC 50/60 Hz (AC-3)15 kW at 415...440 V AC 50/60 Hz (AC-3)18.5 kW at 500 V AC 50/60 Hz (AC-3)18.5 kW at 660...690 V AC 50/60 Hz (AC-3)7.5 kW at 400 V AC 50/60 Hz (AC-4)motor power HP (UL / CSA) 2 hp at 115 V AC 50/60 Hz for 1 phase motors5 hp at 230/240 V AC 50/60 Hz for 1 phase motors7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors10 hp at 230/240 V AC 50/60 Hz for 3 phases motors20 hp at 460/480 V AC 50/60 Hz for 3 phases motors30 hp at 575/600 V AC 50/60 Hz for 3 phases motorscontrol circuit type AC at 50/60 Hz[Uc] control circuit voltage 110 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit50 A (at 60 °C) for power circuitIrms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1550 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity 550 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 260 A 40 °C - 10 s for power circuit430 A 40 °C - 1 s for power circuit60 A 40 °C - 10 min for power circuit138 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-163 A gG at <= 690 V coordination type 1 for power circuit63 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 2 mOhm - Ith 50 A 50 Hz for power circuit[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certifiedelectrical durability 1.65 Mcycles 32 A AC-3 at Ue <= 440 V1.4 Mcycles 50 A AC-1 at Ue <= 440 Vpower dissipation per pole 2 W AC-35 W AC-1safety cover Withmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications GOSTBVLROS (Lloyds register of shipping)RINACCCDNVULCSAGLconnections - terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endPower circuit: screw clamp terminals 1 cable(s) 2.5…10 mm²flexible without cable endPower circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²flexible without cable endPower circuit: screw clamp terminals 1 cable(s) 1…10 mm²flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²flexible with cable endPower circuit: screw clamp terminals 1 cable(s) 1.5…10 mm²solid without cable endPower circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²solid without cable endtightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmPower circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2operating time 12...22 ms closing4...19 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 15 Mcyclesmaximum operating rate 3600 cyc/h 60 °CComplementary coil technology Without built-in suppressor modulecontrol circuit voltage limits Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C)Operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C)Operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C)inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)70 VA 50 Hz cos phi 0.75 (at 20 °C)hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7 VA 50 Hz cos phi 0.3 (at 20 °C)heat dissipation 2…3 W at 50/60 Hzauxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5…60 °Cambient air temperature for storage -60…80 °Cpermissible ambient air temperature around the device -40…70 °C at Ucoperating altitude 3000 m withoutfire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open: 2 Gn, 5...300 HzVibrations contactor closed: 4 Gn, 5...300 HzShocks contactor closed: 15 Gn for 11 msShocks contactor open: 8 Gn for 11 msheight 85 mmwidth 45 mmdepth 92 mmnet weight 0.375 kgOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages15
- English16
- Chinese4
- French3
CatalogueFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 12/07/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter A2 - open, pre-cabled motor starters (Version 6.1)DescriptionFuses- contactors assemblies and circuit breaker-contactors assemblies. Pre-cabled.Size pdfSize 4.1 MBDate 15/05/19DescriptionFuses- contactors assemblies and circuit breaker-contactors assemblies. Pre-cabled.TeSys catalogue - 2019 - 2020 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 7.0)DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesSize pdfSize 12.2 MBDate 15/05/19DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesControl Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Size pdfSize 15 MBDate 06/03/18DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Instruction sheetFormatSizeAdd to My DocumentsLC1D 9 to 38 A AC/DC contactors with screw clamp terminals - Instruction Sheet (Version 09)Descriptionw9137830401a55 w91378304 w9137830401 w9137830401a55 w9137830401a55-10 W913783040211A09 W913783040211 W9137830402Size pdfSize 932.9 KBDate 01/03/17Descriptionw9137830401a55 w91378304 w9137830401 w9137830401a55 w9137830401a55-10 W913783040211A09 W913783040211 W9137830402CADFormatSizeAdd to My DocumentsCAD for LC1D32F7: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 110 V AC coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD for LC1D32F7: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 110 V AC coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CertificateFormatSizeAdd to My DocumentsChina RoHS declarationFormatSizeAdd to My DocumentsLC1D32F7 : LC1D32F7_ROHS_CHINA_DECLARATIONDescriptionLC1D32F7_ROHS_CHINA_DECLARATIONSize pdfSize 195.3 KBDate 16/12/19DescriptionLC1D32F7_ROHS_CHINA_DECLARATIONDeclaration of conformityFormatSizeAdd to My DocumentsSize pdfSize 301 KBDate 28/06/19End of Life InformationFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsLC1D32F7 : LC1D32F7_ROHS_DECLARATIONDescriptionLC1D32F7_ROHS_DECLARATIONSize pdfSize 195.3 KBDate 16/12/19DescriptionLC1D32F7_ROHS_DECLARATIONProduct Environmental ProfileFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My DocumentsLC1D32F7 : LC1D32F7_REACH_DECLARATIONDescriptionLC1D32F7_REACH_DECLARATIONSize pdfSize 195.3 KBDate 16/12/19DescriptionLC1D32F7_REACH_DECLARATION -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.