Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Resistive loadMotor controlutilisation category AC-4AC-3AC-1poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 HzPower circuit: <= 300 V DC[Ie] rated operational current 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit38 A (at <60 °C) at <= 440 V AC AC-3 for power circuitmotor power kW 18.5 kW at 500 V AC 50/60 Hz (AC-3)18.5 kW at 660...690 V AC 50/60 Hz (AC-3)7.5 kW at 400 V AC 50/60 Hz (AC-4)18.5 kW at 380...400 V AC 50/60 Hz (AC-3)9 kW at 220...230 V AC 50/60 Hz (AC-3)18.5 kW at 415...440 V AC 50/60 Hz (AC-3)motor power HP (UL / CSA) 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors10 hp at 200/208 V AC 50/60 Hz for 3 phases motors5 hp at 240 V AC 50/60 Hz for 1 phase motors20 hp at 480 V AC 50/60 Hz for 3 phases motors25 hp at 600 V AC 50/60 Hz for 3 phases motorscontrol circuit type DC standard[Uc] control circuit voltage 24 V DCauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit50 A (at 60 °C) for power circuitIrms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1550 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity 550 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 60 A 40 °C - 10 min for power circuit430 A 40 °C - 1 s for power circuit150 A 40 °C - 1 min for power circuit310 A 40 °C - 10 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-163 A gG at <= 690 V coordination type 1 for power circuit63 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 2 mOhm - Ith 50 A 50 Hz for power circuit[Ui] rated insulation voltage Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certifiedPower circuit: 690 V conforming to IEC 60947-4-1electrical durability 1.4 Mcycles 50 A AC-1 at Ue <= 440 V1.4 Mcycles 38 A AC-3 at Ue <= 440 Vpower dissipation per pole 5 W AC-13 W AC-3safety cover Withmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications RINAGOSTCSABVDNVLROS (Lloyds register of shipping)ULCCCGLconnections - terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endPower circuit: screw clamp terminals 1 cable(s) 2.5…10 mm²flexible without cable endPower circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²flexible without cable endPower circuit: screw clamp terminals 1 cable(s) 1…10 mm²flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²flexible with cable endPower circuit: screw clamp terminals 1 cable(s) 1.5…10 mm²solid without cable endPower circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²solid without cable endtightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmPower circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2operating time 16...24 ms opening53.55...72.45 ms closingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 30 Mcyclesmaximum operating rate 3600 cyc/h 60 °CComplementary coil technology Built-in bidirectional peak limiting diode suppressorcontrol circuit voltage limits Drop-out: 0.1...0.25 Uc DC (at 60 °C)Operational: 0.7...1.25 Uc DC (at 60 °C)time constant 28 msinrush power in W 5.4 W (at 20 °C)hold-in power consumption in W 5.4 W at 20 °Cauxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5…60 °Cambient air temperature for storage -60…80 °Cpermissible ambient air temperature around the device -40…70 °C at Ucoperating altitude 3000 m withoutfire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open: 2 Gn, 5...300 HzVibrations contactor closed: 4 Gn, 5...300 HzShocks contactor closed: 15 Gn for 11 msShocks contactor open: 8 Gn for 11 msheight 85 mmwidth 45 mmdepth 101 mmnet weight 0.54 kgOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your informationEnvironmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages14
- English15
- Chinese5
- French4
CatalogueFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 12/07/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 7.0)DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesSize pdfSize 12.2 MBDate 15/05/19DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesControl Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Size pdfSize 15 MBDate 06/03/18DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Instruction sheetFormatSizeAdd to My DocumentsLC1D 9 to 38 A AC/DC contactors with screw clamp terminals - Instruction Sheet (Version 09)Descriptionw9137830401a55 w91378304 w9137830401 w9137830401a55 w9137830401a55-10 W913783040211A09 W913783040211 W9137830402Size pdfSize 932.9 KBDate 01/03/17Descriptionw9137830401a55 w91378304 w9137830401 w9137830401a55 w9137830401a55-10 W913783040211A09 W913783040211 W9137830402CADFormatSizeAdd to My DocumentsTeSys LC1D contactor 3P 25-38A DC coil (Version 1.0)Files in documentSize zipSize 718.8 KBDate 16/10/13Files in documentCertificateFormatSizeAdd to My DocumentsChina RoHS declarationFormatSizeAdd to My DocumentsLC1D38BD : TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 24 V DC standard coilDescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 24 V DC standard coilSize pdfSize 195.3 KBDate 16/12/19DescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 24 V DC standard coilDeclaration of conformityFormatSizeAdd to My DocumentsSize pdfSize 301 KBDate 28/06/19End of Life InformationFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsLC1D38BD : TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 24 V DC standard coilDescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 24 V DC standard coilSize pdfSize 195.3 KBDate 16/12/19DescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 24 V DC standard coilProduct Environmental ProfileFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My DocumentsLC1D38BD : TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 24 V DC standard coilDescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 24 V DC standard coilSize pdfSize 195.3 KBDate 16/12/19DescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 24 V DC standard coil -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.