View all
TeSys F

LC1F115F5
LC1F115F5
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 110 V AC
Show more characteristics-
Characteristics
Main range TeSysproduct name TeSys Fproduct or component type Contactordevice short name LC1Fcontactor application Motor controlResistive loadutilisation category AC-3AC-4AC-1poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage <= 690 V AC 50/60 Hz[Ie] rated operational current 200 A (at <40 °C) at <= 440 V AC-1115 A (at <55 °C) at <= 440 V AC-3motor power kW 55 kW at 380...400 V AC 50/60 Hz (AC-3)59 kW at 415 V AC 50/60 Hz (AC-3)59 kW at 440 V AC 50/60 Hz (AC-3)75 kW at 500 V AC 50/60 Hz (AC-3)80 kW at 660...690 V AC 50/60 Hz (AC-3)30 kW at 220...230 V AC 50/60 Hz (AC-3)18.5 kW at 400 V AC 50/60 Hz (AC-4)[Uc] control circuit voltage 110 V AC 50 HzComplementary [Uimp] rated impulse withstand voltage 8 kVovervoltage category III[Ith] conventional free air thermal current 200 A (at 40 °C)rated breaking capacity 920 A conforming to IEC 60947-4-1[Icw] rated short-time withstand current 1100 A 40 °C - 10 s640 A 40 °C - 30 s520 A 40 °C - 1 min400 A 40 °C - 3 min320 A 40 °C - 10 minassociated fuse rating 125 A aM at <= 440 V200 A gG at <= 440 Vaverage impedance 0.37 mOhm - Ith 200 A 50 Hz[Ui] rated insulation voltage 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group Cpower dissipation per pole 15 W AC-15 W AC-3mounting support Platestandards EN 60947-4-1IEC 60947-4-1IEC 60947-1JIS C8201-4-1EN 60947-1product certifications DNVRMRoSCCCBVABSCBULRINALROS (Lloyds register of shipping)connections - terminals Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mmPower circuit: lugs-ring terminals 1 cable(s) 95 mm²Power circuit: connector 1 cable(s) 95 mm²Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endPower circuit: bolted connectiontightening torque Power circuit: 10 N.mControl circuit: 1.2 N.mcontrol circuit voltage limits Operational: 0.85...1.1 Uc 50/60 Hz (at 55 °C)Drop-out: 0.35...0.55 Uc 50/60 Hz (at 55 °C)inrush power in VA 550 VA 50 Hz cos phi 0.3 (at 20 °C)hold-in power consumption in VA 45 VA 50 Hz cos phi 0.3 (at 20 °C)heat dissipation 12…16 Woperating time 23...35 ms closing5...15 ms openingmechanical durability 10 Mcyclesmaximum operating rate 2400 cyc/h 55 °Ccompatibility code LC1FEnvironment IP degree of protection IP2x front face with shrouds conforming to IEC 60529IP2x front face with shrouds conforming to VDE 0106protective treatment THambient air temperature for operation -5…55 °Cambient air temperature for storage -60…80 °Cpermissible ambient air temperature around the device -40…70 °Coperating altitude 3000 m withoutheight 162 mmwidth 163.3 mmdepth 171 mmnet weight 3.43 kgOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your informationEnvironmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages16
- English16
- Chinese7
- French9
- German7
- Italian7
- Portuguese7
- Russian7
- Spanish7
Instruction sheetFormatSizeAdd to My DocumentsSize pdfSize 4.5 MBDate 01/04/19CADFormatSizeAdd to My DocumentsSize zipSize 1.7 MBDate 27/03/14Files in documentBrochureFormatSizeAdd to My DocumentsTeSys F 1000 leaflet (Version 1.0)Files in documentSize zipSize 825.6 MBDate 26/11/15Files in documentCertificateFormatSizeAdd to My DocumentsSize pdfSize 389.8 KBDate 14/05/13China RoHS declarationFormatSizeAdd to My DocumentsTeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 110 V ACDescriptionTeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 110 V ACSize pdfSize 195.3 KBDate 06/12/19DescriptionTeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 110 V ACDeclaration of conformityFormatSizeAdd to My DocumentsEnd of Life InformationFormatSizeAdd to My DocumentsSize pdfSize 302.6 KBDate 15/06/10EU RoHS DeclarationFormatSizeAdd to My DocumentsTeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 110 V ACDescriptionTeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 110 V ACSize pdfSize 195.3 KBDate 06/12/19DescriptionTeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 110 V ACMarine certificateFormatSizeAdd to My DocumentsSize pdfSize 20.1 MBDate 16/10/18Size pdfSize 272.4 KBDate 29/05/17Product Environmental ProfileFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My DocumentsTeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 110 V ACDescriptionTeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 110 V ACSize pdfSize 195.3 KBDate 06/12/19DescriptionTeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 110 V AC -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.