View all
TeSys LT47

LT4706F7A
LT4706F7A
TeSys LT47 electronic over current relays-automatic- 0.5...6 A - 100...120 V AC
Show more characteristics-
Characteristics
Main range TeSysproduct name TeSys LTproduct or component type Electronic over current relaydevice short name LT47device application Protectionrelay application Sensitivity to phase failureOverload Imax > IsettingLocked rotor, mechanical jamming I > 3 x Isetting[Us] rated supply voltage 100...120 V ACthermal protection adjustment range 0.5…6 A[Ui] rated insulation voltage Power circuit: 600 V AC conforming to CSAPower circuit: 600 V AC conforming to ULPower circuit: 690 V AC conforming to IEC 60947-4-1Complementary network frequency 50...60 Hzmounting support Railtripping threshold 0.5...5 Aelectromagnetic compatibility Resistance to electrostatic discharge: 8 kV in open air conforming to IEC 61000-4-2Resistance to electrostatic discharge: 6 kV in direct mode conforming to IEC 61000-4-2Conducted emission: class A conforming to EN 55011Immunity to electromagnetic interference: 10 V/m conforming to IEC 61000-4-3Immunity to fast transients: 2 kV conforming to IEC 61000-4-4Surge withstand: 6 kV conforming to IEC 61000-4-5Conducted HF disturbances: 10 V conforming to IEC 61000-4-6auxiliary contact composition 1 NO + 1 NC[Ith] conventional free air thermal current 3 A for signalling circuitassociated fuse rating 3 A gG for signalling circuit3 A BS for signalling circuit[Uimp] rated impulse withstand voltage 6 kVtime range 1...120 s - control type R-time0.3...30 s - control type O-timelocal signalling 1 LED (green) 1 LED (red)control type automatic: resetconnections - terminals Signalling circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable endSignalling circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible without cable endSignalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endSignalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable endtightening torque Signalling circuit: 1.7 N.m M3.5height 70.3 mmwidth 71 mmdepth 77.2 mmnet weight 0.192 kgEnvironment standards IEC 60947IEC 60255-6product certifications CSAULprotective treatment TH conforming to IEC 60068IP degree of protection IP20 conforming to IEC 60529IP20 conforming to VDE 0106ambient air temperature for operation -25…60 °C without derating conforming to IEC 60947-4-1ambient air temperature for storage -30…80 °Coperating altitude 2000 mmechanical robustness Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7Vibrations: 4 gn conforming to IEC 60068-2-6dielectric strength 2 kV at 50 Hz conforming to IEC 60255-5Offer Sustainability EU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your informationWEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages14
- English15
- French9
- German9
- Italian9
CatalogueFormatSizeAdd to My DocumentsTeSys catalogue - 2019 - 2020 - chapter B11 Overload relays TeSys LRK, LRD, LR9, RM1, LT3 (Version 7.0)DescriptionThermal overload relays : TeSys LRK, LRDElectronic thermal overload relays : TeSys LR9, LR9FSIgnle pole overcurrent relay : TeSys RM1PTC-type protection relay: TeSys LT3Size pdfSize 5.5 MBDate 15/05/19DescriptionThermal overload relays : TeSys LRK, LRDElectronic thermal overload relays : TeSys LR9, LR9FSIgnle pole overcurrent relay : TeSys RM1PTC-type protection relay: TeSys LT3Instruction sheetFormatSizeAdd to My DocumentsSize pdfSize 147.4 KBDate 01/02/11Size pdfSize 138.7 KBDate 01/02/11Size pdfSize 136.7 KBDate 01/02/11CADFormatSizeAdd to My DocumentsElectronic over current relays LT47 for 0.5 at 60A, with relay setting range, with reset (Version 1.0)Files in documentSize zipSize 222.6 KBDate 24/01/07Files in documentElectronic over current relays LT47 for 0.5 at 60A, with relay setting range, with reset (Version 1.0)Files in documentSize zipSize 103.1 KBDate 24/01/07Files in documentCertificateFormatSizeAdd to My DocumentsChina RoHS declarationFormatSizeAdd to My DocumentsTeSys LT47 electronic over current relays-automatic- 0.5...6 A - 100...120 V ACDescriptionTeSys LT47 electronic over current relays-automatic- 0.5...6 A - 100...120 V ACSize pdfSize 195.3 KBDate 06/12/19DescriptionTeSys LT47 electronic over current relays-automatic- 0.5...6 A - 100...120 V ACEnd of Life InformationFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsTeSys LT47 electronic over current relays-automatic- 0.5...6 A - 100...120 V ACDescriptionTeSys LT47 electronic over current relays-automatic- 0.5...6 A - 100...120 V ACSize pdfSize 195.3 KBDate 06/12/19DescriptionTeSys LT47 electronic over current relays-automatic- 0.5...6 A - 100...120 V ACProduct Environmental ProfileFormatSizeAdd to My DocumentsTeSys contactor LC1F (Version 2.0)DescriptionPEPSize pdfSize 197.1 KBDate 08/09/15DescriptionPEP -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.