View all Preventa XPS
Schneider Eletric XPSATR11530C Picture

XPSATR11530C

Schneider Eletric XPSATR11530C Picture
XPSATR11530C

module XPSATR - Emergency stop and protective guard - 24V DC, time delay 30s

Show more characteristics >
  • RRP
    435.00 GBP
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Preventa Safety automation
    product or component type
    Preventa safety module
    safety module name
    XPSATR
    safety module application
    For emergency stop and protective guard applications
    function of module
    Emergency stop monitoring 1-channel wiring
    Protective guard monitoring
    Emergency stop monitoring 2-channel wiring
    safety level
    Can reach PL e/category 4 instantaneous safety outputs conforming to EN/ISO 13849-1
    Can reach SILCL 3 time delay safety outputs conforming to EN/IEC 62061
    safety reliability data
    DC > 99 % conforming to EN/ISO 13849-1
    MTTFd = 85 years conforming to EN/ISO 13849-1
    PFHd = 2E-9 1/h conforming to EN/IEC 62061
    type of start
    Automatic
    Manual
    connections - terminals
    Cage clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid or flexible without cable end
    Cage clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel
    Cage clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel
    Cage clamp terminals, removable terminal block, 2 x 0.5...2 x 1 mm² flexible with cable end, with bezel
    Cage clamp terminals, removable terminal block
    output type
    Relay instantaneous opening, 3 NO circuit(s), volt-free
    Relay time delay opening, 3 NO circuit(s), volt-free
    number of additional circuits
    1 NC
    [Us] rated supply voltage
    24 V DC - 15...10 %
    Complementary
    synchronisation time between inputs
    1 s
    maximum power consumption in W
    2.8 W DC
    input protection type
    Internal, electronic
    time delay range
    0...30 s
    [Uc] control circuit voltage
    24 V DC
    breaking capacity
    3 A at 24 V (DC-13) for relay output
    output thermal current
    6 A for instantaneous and time delay outputs
    [Ith] conventional free air thermal current
    8 A
    associated fuse rating
    6 A gG for instantaneous and time delay outputs conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    minimum output current
    10 mA for relay output
    minimum output voltage
    17 V for relay output
    maximum response time on input open
    20 ms
    [Ui] rated insulation voltage
    300 V
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
    local signalling
    5 LEDs
    mounting support
    35 mm symmetrical DIN rail
    net weight
    0.33 kg
    Environment
    standards
    EN/IEC 60947-5-1
    EN/IEC 61496-1
    EN 62061
    EN/ISO 13849-1
    EN 60204-1
    EN 50156-1
    product certifications
    CSA
    TÜV
    UL
    IP degree of protection
    IP20 (terminals) conforming to EN/IEC 60529
    IP40 (enclosure) conforming to EN/IEC 60529
    ambient air temperature for operation
    -25…55 °C
    ambient air temperature for storage
    -25…75 °C
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Toxic heavy metal free
    Yes
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • Documents and Downloads

    Language
    • English
    • French
    • Chinese
    • German
    Instruction sheet
    Date
    Size
    Add to My Documents
    XPSATR... Safety Relay for monitoring EMERGENCY STOP circuits and protective guard applications, Instruction sheet (Version 00)
    CAD
    Date
    Size
    Add to My Documents
    CAD for XPSATR11530C: module XPSATR - Emergency stop and protective guard - 24V DC, time delay 30s (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    CCC_2013010303592422_Certificate_XPSAXE_valid_20221220 (Version 1.3)
    XPSATR Type Examination (Version 1.0)
    Date 25/11/16
    Size 614 KB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Preventa DoC XPSATR (Version 1.0)
    Date 12/06/18
    Size 530.8 KB
    End of Life Information
    Date
    Size
    Add to My Documents
    XPS... Preventa Safety Module, Product End-of-Life Instructions (Version 2.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 22/09/19
    Size 195.3 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    XPS... Preventa Safety Module, Product Environmental Profile (Version 2.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 22/09/19
    Size 195.3 KB
    RoHs China Declaration
    Date
    Size
    Add to My Documents
    Date 22/09/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



Compare products: /