United Kingdom
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Preventa XPS
Schneider Eletric XPSAV11113P Picture

XPSAV11113P

Green premium brand logo
Schneider Eletric XPSAV11113P Picture
XPSAV11113P
Green premium brand logo

module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s

Show more characteristics
  • RRP
    381.00 GBP
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Preventa Safety automation
    product or component type
    Preventa safety module
    safety module name
    XPSAV
    safety module application
    For emergency stop and switch monitoring
    function of module
    Monitoring of a movable guard associated with 2 switches automatic start
    Emergency stop monitoring 1-channel wiring
    Emergency stop button with 1 NC contact, automatic start or unmonitored start
    Emergency stop monitoring 2-channel wiring
    Emergency stop button with 2 NC contacts, monitored start
    safety level
    Can reach PL e/category 4 conforming to EN/ISO 13849-1
    Can reach SILCL 3 conforming to EN/IEC 62061
    safety reliability data
    DC > 99 % conforming to EN/ISO 13849-1
    MTTFd = 75.8 years conforming to EN/ISO 13849-1
    PFHd = 7.95E-9 1/h conforming to EN/IEC 62061
    type of start
    Configurable
    connections - terminals
    Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
    output type
    Relay instantaneous opening, 3 NO circuit(s), volt-free
    Relay time delay opening, 3 NO circuit(s), volt-free
    number of additional circuits
    3 solid state outputs
    [Us] rated supply voltage
    24 V DC - 20...20 %
    Complementary
    synchronisation time between inputs
    Unlimited for emergency stop
    1.5 s for guard
    maximum power consumption in W
    5 W DC
    input protection type
    Internal, electronic
    time delay range
    0...300 s
    [Uc] control circuit voltage
    24 V DC
    maximum line resistance
    100 Ohm <2000 m
    breaking capacity
    180 VA holding AC-15 C300 relay output
    1800 VA inrush AC-15 C300 relay output
    breaking capacity
    20 mA at 24 V
    1.25 A at 24 V (DC-13) time constant: 50 ms for relay output
    output thermal current
    2 A for 1 output and 4 A for the other 2 outputs for instantaneous and time delay outputs
    3.3 A for all 3 outputs for instantaneous and time delay outputs
    6 A for 1 output and 2 A for the other 2 outputs for instantaneous and time delay outputs
    [Ith] conventional free air thermal current
    20 A
    associated fuse rating
    4 A gG or gL for instantaneous and time delay outputs conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    6 A fast blow conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    minimum output current
    10 mA for relay output
    minimum output voltage
    17 V for relay output
    maximum response time on input open
    30 ms
    [Ui] rated insulation voltage
    300 V (pollution degree 2) conforming to IEC 60947-5-1
    300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category III conforming to IEC 60947-5-1
    4 kV overvoltage category III conforming to DIN VDE 0110 part 1
    local signalling
    11 LEDs
    mounting support
    35 mm symmetrical DIN rail
    net weight
    0.32 kg
    Environment
    standards
    EN 1088/ISO 14119
    EN/IEC 60204-1
    EN/ISO 13850
    EN/IEC 60947-5-1
    product certifications
    TÜV
    UL
    CSA
    IP degree of protection
    IP20 (terminals) conforming to EN/IEC 60529
    IP40 (enclosure) conforming to EN/IEC 60529
    ambient air temperature for operation
    -10…55 °C
    ambient air temperature for storage
    -25…85 °C
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages11
    • English11
    • Chinese4
    • French4
    • German4
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 721.3 KB
    Date 01/03/10
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD for XPSAV11113P: module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    CAD for XPSAV11113P: module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    Certificate
    Format
    Size
    Date
    Add to My Documents
    CCC_2007010303245539_Certificate_XPSAC_valid_20200227 (Version 1.1)
    Description
    CCC certificate of XPSAC, XPSAF, XPSAFL, XPSAK, XPSAR, XPSAV, XPSBF, XPSCM, XPSDMB, XPSDME, XPSMP, XPSTSA, XPSTSW, XPSVC, XPSATE, XPSVNE
    Size pdf
    Size 11.4 MB
    Date 23/04/19
    Description
    CCC certificate of XPSAC, XPSAF, XPSAFL, XPSAK, XPSAR, XPSAV, XPSBF, XPSCM, XPSDMB, XPSDME, XPSMP, XPSTSA, XPSTSW, XPSVC, XPSATE, XPSVNE
    Size pdf
    Size 1.2 MB
    Date 23/03/18
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 541.3 KB
    Date 12/06/18
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s
    Description
    module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s
    Size pdf
    Size 195.3 KB
    Date 15/11/19
    Description
    module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 2.2 MB
    Date 01/05/18
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s
    Description
    module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s
    Size pdf
    Size 195.3 KB
    Date 15/11/19
    Description
    module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s
    RoHs China Declaration
    Format
    Size
    Date
    Add to My Documents
    module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s
    Description
    module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s
    Size pdf
    Size 195.3 KB
    Date 15/11/19
    Description
    module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



Compare products: /