  • Main
    range of product
    Preventa Safety automation
    product or component type
    Preventa safety module
    safety module name
    XPSAV
    safety module application
    For emergency stop and switch monitoring
    function of module
    Monitoring of a movable guard associated with 2 switches automatic start
    Emergency stop monitoring 1-channel wiring
    Emergency stop button with 1 NC contact, automatic start or unmonitored start
    Emergency stop monitoring 2-channel wiring
    Emergency stop button with 2 NC contacts, monitored start
    safety level
    Can reach PL e/category 4 conforming to EN/ISO 13849-1
    Can reach SILCL 3 conforming to EN/IEC 62061
    safety reliability data
    DC > 99 % conforming to EN/ISO 13849-1
    MTTFd = 75.8 years conforming to EN/ISO 13849-1
    PFHd = 7.95E-9 1/h conforming to EN/IEC 62061
    type of start
    Configurable
    connections - terminals
    Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
    output type
    Relay instantaneous opening, 3 NO circuit(s), volt-free
    Relay time delay opening, 3 NO circuit(s), volt-free
    number of additional circuits
    3 solid state outputs
    [Us] rated supply voltage
    24 V DC - 20...20 %
    Complementary
    synchronisation time between inputs
    Unlimited for emergency stop
    1.5 s for guard
    maximum power consumption in W
    5 W DC
    input protection type
    Internal, electronic
    time delay range
    0...300 s
    [Uc] control circuit voltage
    24 V DC
    maximum line resistance
    100 Ohm <2000 m
    breaking capacity
    180 VA holding AC-15 C300 relay output
    1800 VA inrush AC-15 C300 relay output
    breaking capacity
    20 mA at 24 V
    1.25 A at 24 V (DC-13) time constant: 50 ms for relay output
    output thermal current
    2 A for 1 output and 4 A for the other 2 outputs for instantaneous and time delay outputs
    3.3 A for all 3 outputs for instantaneous and time delay outputs
    6 A for 1 output and 2 A for the other 2 outputs for instantaneous and time delay outputs
    [Ith] conventional free air thermal current
    20 A
    associated fuse rating
    4 A gG or gL for instantaneous and time delay outputs conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    6 A fast blow conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    minimum output current
    10 mA for relay output
    minimum output voltage
    17 V for relay output
    maximum response time on input open
    30 ms
    [Ui] rated insulation voltage
    300 V (pollution degree 2) conforming to IEC 60947-5-1
    300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category III conforming to IEC 60947-5-1
    4 kV overvoltage category III conforming to DIN VDE 0110 part 1
    local signalling
    11 LEDs
    mounting support
    35 mm symmetrical DIN rail
    net weight
    0.32 kg
    Environment
    standards
    EN 1088/ISO 14119
    EN/IEC 60204-1
    EN/ISO 13850
    EN/IEC 60947-5-1
    product certifications
    TÜV
    UL
    CSA
    IP degree of protection
    IP20 (terminals) conforming to EN/IEC 60529
    IP40 (enclosure) conforming to EN/IEC 60529
    ambient air temperature for operation
    -10…55 °C
    ambient air temperature for storage
    -25…85 °C
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Not applicable, out of EU RoHS legal scope
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • Documents

    Language
    • English
    • French
    • Chinese
    • German
    Instruction sheet
    Date
    Size
    Add to My Documents
    XPSAV... Safety module for emergency stop and switch monitoring (Version 00)
    CAD
    Date
    Size
    Add to My Documents
    CAD for XPSAV11113P: module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    XPSAC AF AFL AK AR ATE AV Type Examination (Version 2.0)
    CCC_2007010303245539_Certificate_XPSAC_valid_20200227 (Version 1.1)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Preventa DoC XPSAF XPSAFL XPSAK XPSAR XPSATE XPSAV (Version 1.0)
    End of Life Information
    Date
    Size
    Add to My Documents
    XPS... Preventa Safety Module, Product End-of-Life Instructions (Version 2.0)
    XPS ABV..., XPS AC..., XPS AF..., XPS AX..., XPS BCE..., XPS BF..., XPS DMB..., XPS ECME..., XPS-VC... Safety Modules, Product End-of-Life Instructions (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 18/10/19
    Size 195.3 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    XPS... Preventa Safety Module, Product Environmental Profile (Version 2.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 18/10/19
    Size 195.3 KB
    RoHs China Declaration
    Date
    Size
    Add to My Documents
    Date 18/10/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



Compare products: /