  • Main
    range of product
    Preventa Safety automation
    product or component type
    Safety controller with pre-defined function
    safety module name
    XPSMP
    safety module application
    2 independent functions
    safety use category
    Category 4 maximum conforming to EN/IEC 60954-1
    type of start
    Automatic or unmonitored (configuration 1)
    Automatic or unmonitored (configuration 10)
    Automatic or unmonitored (configuration 11)
    Automatic or unmonitored (configuration 14)
    Automatic or unmonitored (configuration 3)
    Automatic or unmonitored (configuration 5)
    Automatic or unmonitored (configuration 7)
    Monitored (configuration 12)
    Monitored (configuration 13)
    Monitored (configuration 15)
    Monitored (configuration 2)
    Monitored (configuration 4)
    Monitored (configuration 6)
    Monitored (configuration 8)
    Monitored (configuration 9)
    checks
    Configuration (configuration 10)
    Configuration (configuration 13)
    Configuration (configuration 3)
    Configuration (configuration 4)
    Configuration (configuration 5)
    Configuration (configuration 6)
    Configuration (configuration 9)
    standards
    EN/IEC 60947-1 + A11
    EN/IEC 60947-5-1
    EN/IEC 60204-1
    DIN V VDE 801 + A1
    product certifications
    UL
    CSA
    BIA
    [Us] rated supply voltage
    24 V DC - 20...20 %
    connections - terminals
    Captive screw clamp terminals flexible cable: 0.14...0.75 mm² without cable end, 2 wires
    Captive screw clamp terminals solid cable: 0.14...0.75 mm² without cable end, 2 wires
    Captive screw clamp terminals flexible cable: 0.14...2.5 mm² without cable end, 1 wire
    Captive screw clamp terminals solid cable: 0.14...2.5 mm² without cable end, 1 wire
    Captive screw clamp terminals flexible cable: 0.25...1 mm² with cable end, without bezel, 2 wires
    Captive screw clamp terminals flexible cable: 0.25...1.5 mm² with cable end, with bezel, 1 wire
    Captive screw clamp terminals flexible cable: 0.25...2.5 mm² with cable end, without bezel, 1 wire
    Captive screw clamp terminals flexible cable: 0.5...1.5 mm² with cable end, with double bezel, 2 wires
    safety level
    Can reach PL e/category 4 conforming to EN/ISO 13849-1
    Can reach SIL 3 conforming to EN/IEC 62061
    Complementary
    function of module
    Configuration 0: functions disabled (factory setting)
    Configuration 1: emergency stop monitoring 1-channel wiring, category 2
    Configuration 10: enabling grip switch monitoring (3-position switch), category 4
    Configuration 11: sensing mat and edges monitoring, category 3
    Configuration 12: sensing mat and edges monitoring, category 3
    Configuration 13: relay output safety light curtain monitoring, category 4
    Configuration 14: coded magnetic switch monitoring, category 4
    Configuration 15: coded magnetic switch monitoring, category 4
    Configuration 2: emergency stop monitoring 1-channel wiring, category 2
    Configuration 3: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
    Configuration 4: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
    Configuration 5: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
    Configuration 6: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
    Configuration 7: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
    Configuration 8: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
    Configuration 9: guard monitoring for injection presses and blowing machines, category 4
    synchronisation time between inputs
    0.5 s (configuration 13)
    1.5 s (configuration 14)
    1.5 s (configuration 15)
    1.5 s (configuration 5)
    1.5 s (configuration 6)
    1.5 s (configuration 9)
    Unlimited (configuration 3)
    Unlimited (configuration 4)
    Unlimited (configuration 7)
    Unlimited (configuration 8)
    maximum power consumption in W
    5 W
    input protection type
    Internal, electronic
    [Uc] control circuit voltage
    24 V
    maximum line resistance
    100 Ohm <2000 m
    number of safety circuits
    3 NO relays per function (6 NO total), volt-free
    number of additional circuits
    3 solid state outputs
    breaking capacity
    180 VA holding AC-15 C300 relay output
    1800 VA inrush AC-15 C300 relay output
    breaking capacity
    20 mA at 24 V for static output circuit
    1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
    output thermal current
    2 A for 1 output and 4 A for the other 2 outputs for relay
    3.3 A for all 3 outputs relay simultaneously
    6 A for 1 output and 2 A for the other 2 outputs for relay
    [Ith] conventional free air thermal current
    20 A
    associated fuse rating
    4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    minimum output current
    10 mA for relay output
    minimum output voltage
    17 V for relay output
    maximum response time on input open
    30 ms
    [Ui] rated insulation voltage
    300 V (pollution degree 2) conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
    local signalling
    12 LEDs
    mounting support
    35 mm symmetrical DIN rail
    depth
    114 mm
    height
    99 mm
    width
    45 mm
    net weight
    0.32 kg
    Environment
    IP degree of protection
    IP20 (terminals)
    IP40 (enclosure)
    ambient air temperature for operation
    -10…55 °C
    ambient air temperature for storage
    -25…85 °C
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages11
    • English11
    • Chinese4
    • French4
    • German4
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 889.1 KB
    Date 01/11/00
    Description
    None
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD for XPSMP11123: module XPS-MP - 2 independent functions - 24 V DC (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    CAD for XPSMP11123: module XPS-MP - 2 independent functions - 24 V DC (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    Certificate
    Format
    Size
    Date
    Add to My Documents
    CCC_2007010303245539_Certificate_XPSAC_valid_20200227 (Version 1.1)
    Description
    CCC certificate of XPSAC, XPSAF, XPSAFL, XPSAK, XPSAR, XPSAV, XPSBF, XPSCM, XPSDMB, XPSDME, XPSMP, XPSTSA, XPSTSW, XPSVC, XPSATE, XPSVNE
    Size pdf
    Size 11.4 MB
    Date 23/04/19
    Description
    CCC certificate of XPSAC, XPSAF, XPSAFL, XPSAK, XPSAR, XPSAV, XPSBF, XPSCM, XPSDMB, XPSDME, XPSMP, XPSTSA, XPSTSW, XPSVC, XPSATE, XPSVNE
    Size pdf
    Size 618.3 KB
    Date 23/03/18
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 520.1 KB
    Date 12/06/18
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 2.2 MB
    Date 01/05/18
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    module XPS-MP - 2 independent functions - 24 V DC
    Description
    module XPS-MP - 2 independent functions - 24 V DC
    Size pdf
    Size 195.3 KB
    Date 17/11/19
    Description
    module XPS-MP - 2 independent functions - 24 V DC
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 2.2 MB
    Date 01/05/18
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    module XPS-MP - 2 independent functions - 24 V DC
    Description
    module XPS-MP - 2 independent functions - 24 V DC
    Size pdf
    Size 195.3 KB
    Date 17/11/19
    Description
    module XPS-MP - 2 independent functions - 24 V DC
    RoHs China Declaration
    Format
    Size
    Date
    Add to My Documents
    module XPS-MP - 2 independent functions - 24 V DC
    Description
    module XPS-MP - 2 independent functions - 24 V DC
    Size pdf
    Size 195.3 KB
    Date 17/11/19
    Description
    module XPS-MP - 2 independent functions - 24 V DC
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



  • Connections and Schema

    Wiring Diagrams
    Refer to the Instruction Sheet

    To download the instruction sheet, follow below procedure:


    1
    Click on Download & Documents.
    2
    Click on Instruction sheet.


  • Technical Description

    Safety Functions


    • Emergency stop monitoring, 1 channel wiring:

      • 1 channel Emergency stop, automatic or unmonitored start.

      • 1 channel Emergency stop, monitored start.

    • Emergency stop monitoring, 2 channel wiring:

      • 2 channel Emergency stop, automatic or unmonitored start.

      • 2 channel Emergency stop, monitored start.


    • Coded magnetic switch monitoring:

      • Automatic or unmonitored start, synchronization time = 1,5 s.

      • Monitored start, synchronization time = 1,5 s.


    • Guard monitoring with start test:

      • Locking of guard with start test, automatic or unmonitored start.

      • Locking of guard with start test, monitored start.

    • Guard monitoring with start test and synchronization time = 1,5 ms:

      • Locking of guard with start test, automatic or unmonitored start.

      • Locking of guard with start test, monitored start.

    • Guard monitoring for injection press or blowing machine.


    • Enabling switch monitoring, safety mat monitoring:

      • Enabling switch monitoring, with or without start-up preparation.

      • Safety mat monitoring, automatic or unmonitored start.


    • Sensing mat monitoring, monitored start.


    • Light curtain monitoring, monitored start, synchronization time = 0,5 s.