Water Usage at AI Scale: Insights from a 100 MW Comparative Analysis

Water consumption has become one of the most pronounced community concerns surrounding the rapid expansion of large-scale AI deployments. Yet the amount of water a data center consumes is not determined by its size or workload alone. Cooling technology and design play a significant role in shaping this outcome. Therefore, water use for heat rejection should be viewed as a design choice rather than an inherent requirement. Adiabatic-assist can reduce cooling energy consumption and lower PUE, creating a water-energy tradeoff. However, once the technology cooling system (TCS) supply temperature is optimized, the incremental energy benefit can diminish. We compare four 100 MW data center designs ranging from a traditional air-cooled architecture to optimized liquid-cooled AI architectures, using representative climates and operating strategies to show how cooling technologies influence water efficiency at scale. Key takeaways 1. Cooling strategy is central to AI infrastructure planning. The cooling architecture directly impacts a data center’s water and energy footprint. It should therefore be evaluated early in the design process based on water and energy availability, cost, operational requirements, regulations and sustainability goals. 2. Data center water use is determined by how heat is rejected outdoors; and can be greatly reduced by using liquid cooling indoors. Outdoor heat rejection systems may use water to improve heat exchange efficiency. Indoor liquid cooling can reduce the proportion of mechanical cooling by lowering chilled-water demand and increase the operating hours in “free-cooling” mode. Together, these effects can significantly reduce water and energy consumption. 3. Moving from air cooling to liquid cooling consistently improves energy efficiency and can reduce water use in water-constrained locations. In the 100 MW simulations, moving from traditional air cooling to liquid cooling at a 32°C TCS supply temperature reduced on-site water use by ~8% in Dallas, Texas. It also reduced PUE by ~7% (cooling overhead by ~63%) in both Dallas and Paris, France; demonstrating that the energy-benefits apply across different climates. 4. Higher liquid cooling temperatures provide substantial additional water savings. Raising the TCS supply temperature from 32°C to 45°C extends the range of outdoor temperatures in which free cooling can operate. This reduced WUE by ~66% to ~82% depending on location; and PUE by ~0.6% (cooling overhead by ~13%). Alternatively, adjusting equipment count to prevent stranded cooling capacity and reduce CapEx, decreased WUE by ~50% and PUE by ~0.5% (cooling overhead by ~11%) compared to the 32°C baseline. 5. On-site cooling water use is a design and operating choice, not an unavoidable result of climate. Our simulations show that implementing liquid cooling at high TCS temperatures maximizes cooling efficiency across locations, to the point where using water to further lower PUE produces negligible improvements. While climate affects cooling performance, it does not determine water use on its own. Heat rejection technology, liquid cooling, TCS temperature, and equipment choices can substantially mitigate water use in both cooler and warmer locations.

Water Usage at AI Scale: Insights from a 100 MW Comparative Analysis

Release date 21 Sept 2026
Version 1.0
Document ref. SPD_WP220_EN
File format PDF (4.6 MB)
File name | Size | Action WP220_V1_EN.pdf 4.6 MB

Water Usage at AI Scale: Insights from a 100 MW Comparative Analysis

Water consumption has become one of the most pronounced community concerns surrounding the rapid expansion of large-scale AI deployments. Yet the amount of water a data center

Release date 21 Sept 2026
Version 1.0
Document ref. SPD_WP220_EN
File format PDF (4.6 MB)
WP220_V1_EN.pdf
Release date 21 Sept 2026
Version 1.0
File name WP220_V1_EN.pdf
File format PDF