log on as batch job right required when running a PME database task

Published date: 04 June 2020

Issue
The following error occurrs when running [ION_Network] - Maintenance scheduled task:

          
          This task requires that the user account specified has log on as batch job rights. For more information about setting this policy, see the Task Security Context topic in Help.

Product Line
Power Monitoring Expert

note: Applies to any version that uses Task Scheduler to run PME databases maintenance and backup jobs.

Environment
Windows Task Scheduler

Cause
Insufficeint permission

Resolution
1. Open Local Security Policy from Administrative Tools

2. Navigate to Local Policies > User Rights Assignment

3. Find 'Log on as a batch job' group on the right pane and open it's property window

4. Add 'IONMaintenance' user to the group


          
 