USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Select your location
View all NetShelter Basic Rack PDUs
Schneider Eletric AP7541 Picture

AP7541

Schneider Eletric AP7541 Picture
AP7541

Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Overview
    Model Name
    Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19
    Includes
    Installation guide , Rack Mounting brackets , Toolless Mounting Kit
    Standard Lead Time
    Usually in Stock
    Product Distribution
    Anguilla , Antigua And Barbuda , Argentina , Aruba , Bahamas , Barbados , Belize , Bermuda , Bolivia , Brazil , Canada , Chile , Colombia , Costa Rica , Cuba , Dominica , Dominican Republic , Ecuador , El Salvador , Falkland Islands (Malvinas) , Grenada , Guadeloupe , Guatemala , Guyana , Haiti , Honduras , Jamaica , Japan , Martinique , Mexico , Netherlands Antilles , Nicaragua , Panama , Paraguay , Peru , Puerto Rico , SAINT KITTS AND NEVIS , SAINT VINCENT AND THE GRENADINES , Taiwan , Trinidad And Tobago , Turks And Caicos Islands , United States , Uruguay , Venezuela , VIRGIN ISLANDS (UNITED STATES)
    Output
    Nominal Output Voltage
    200V , 208V
    Maximum Total Current Draw per Phase
    24 A
    Output Connections
    (20) IEC 320 C13 (Battery Backup) , (4) IEC 320 C19 (Battery Backup)
    Overload Protection
    Yes
    Input
    Nominal Input Voltage
    200V
    208V
    230V
    Input Frequency
    50/60 Hz
    Regulatory Derated Input Current (North America)
    24 A
    Input Connections
    NEMA L6-30P
    Cord Length
    10 feet (3.05 meters)
    Number of Power Cords
    1
    Maximum Input Current per phase
    30 A
    Load Capacity
    4992 VA
    Physical
    Net Weight
    12.25 lbs (5.57 kg)
    Maximum Height
    63.75 inches (1619.0 mm)
    Maximum Width
    2.19 inches (56.0 mm)
    Maximum Depth
    1.73 inches (44.0 mm)
    Shipping Weight
    14.25 lbs (6.48 kg)
    Shipping Height
    83.5 inches (2121.0 mm)
    Shipping Width
    6.0 inches (152.0 mm)
    Shipping Depth
    5.0 inches (127.0 mm)
    Color
    Black
    Environmental
    Operating Environment
    32 - 113 °F (0 - 45 °C)
    Operating Relative Humidity
    0 - 95 %
    Operating Elevation
    0-10000 feet (0-3000 meters)
    Storage Temperature
    -13 - 149 °F (-25 - 65 °C)
    Storage Relative Humidity
    0 - 95 %
    Storage Elevation
    0-50000 feet (0-15000 meters)
    Conformance
    Approvals
    CSA C22.2 No. 60950-1-03 , METI Denan , PSE , UL 60950-1 , UL Listed , cUL Listed
    Standard warranty
    2 years repair or replace
    Sustainable Offer Status
    RoHS
    Compliant
    REACH
    REACH: Contains No SVHCs
  • View more View less

    Documents

    Language
    • All Languages15
    • English13
    • French1
    • Spanish1
    Catalog
    Format
    Size
    Date
    Add to My Documents
    APC Modular Power Distribution, Modular Power Accessories, and Rack PDUs: 208 and 415V Compatibility Chart (Version 6)
    Files in document
    pdf
    47.9 KB
    pdf
    47.9 KB
    Description
    Chart that specifies the APC Modular Power Distribution Units that support the installation of APC 208V & 415V Power Distribution Modules and specifies compatible APC Rack PDUs for each PDM.
    Size zip
    Size 95.8 KB
    Date 3/18/16
    Files in document
    pdf
    47.9 KB
    pdf
    47.9 KB
    Description
    Chart that specifies the APC Modular Power Distribution Units that support the installation of APC 208V & 415V Power Distribution Modules and specifies compatible APC Rack PDUs for each PDM.
    Rack Power Distribution Unit (PDU) Pocket Guide (Version 2)
    Files in document
    Description
    Brochure including Basic, Metered, Switched, and Metered by Outlet Rack PDUs product features and specifications
    Size zip
    Size 10.4 MB
    Date 5/14/15
    Files in document
    Description
    Brochure including Basic, Metered, Switched, and Metered by Outlet Rack PDUs product features and specifications
    User guide
    Format
    Size
    Date
    Add to My Documents
    Basic Rack PDU Installation and Quick-Start (Manual) (Version 0)
    Files in document
    pdf
    458.5 KB
    pdf
    461.6 KB
    Description
    Installation
    Size zip
    Size 920.1 KB
    Date 2/24/06
    Files in document
    pdf
    458.5 KB
    pdf
    461.6 KB
    Description
    Installation
    Size pdf
    Size 495.9 KB
    Date 2/24/06
    Description
    installation
    Size pdf
    Size 506 KB
    Date 2/24/06
    Description
    Instalación
    CAD
    Format
    Size
    Date
    Add to My Documents
    AP7541 - Rack PDU, Basic, Double pole CB (Version 2)
    Files in document
    pdf
    655.5 KB
    Description
    Power Distribution, Basic Rack PDU
    Size zip
    Size 1.2 MB
    Date 8/25/09
    Files in document
    pdf
    655.5 KB
    Description
    Power Distribution, Basic Rack PDU
    Specification guide
    Format
    Size
    Date
    Add to My Documents
    Basic Rack PDU AP7541 (Sheet) (Version 1)
    Files in document
    pdf
    111.7 KB
    zip
    89.1 KB
    Description
    Technical Specifications
    Size zip
    Size 200.8 KB
    Date 6/23/09
    Files in document
    pdf
    111.7 KB
    zip
    89.1 KB
    Description
    Technical Specifications
    Certificate
    Format
    Size
    Date
    Add to My Documents
    CCC Exemption Letter (Version 1)
    Description
    Exemption letter issued by UL China for PDUs
    Size pdf
    Size 1.5 MB
    Date 11/6/18
    Description
    Exemption letter issued by UL China for PDUs
    UL/C-UL Approval E177299 (Version 12)
    Description
    North American Safety Approval for Device Management, Access and Environmental Management, Rack Power Distribution and PDU products.
    Size pdf
    Size 97.8 KB
    Date 2/12/18
    Description
    North American Safety Approval for Device Management, Access and Environmental Management, Rack Power Distribution and PDU products.
    Size pdf
    Size 144.5 KB
    Date 1/29/17
    Description
    DENAN Statement of Conformity Assessment
    DENAN Agency Approval - NBK190615-E177299 Denan PSE Approval Multiple Socket Outlet rPDU (Version 1)
    Files in document
    pdf
    91.4 KB
    pdf
    91.4 KB
    Description
    UL DENAN Cert for rPDU exceeding 125V, 20-30A
    Size zip
    Size 182.8 KB
    Date 5/10/16
    Files in document
    pdf
    91.4 KB
    pdf
    91.4 KB
    Description
    UL DENAN Cert for rPDU exceeding 125V, 20-30A
    Instruction Sheet
    Format
    Size
    Date
    Add to My Documents
    Rack PDU Accessories Circuit Breaker Operation (Sheet) (Version 1)
    Files in document
    pdf
    74.7 KB
    zip
    89.1 KB
    Description
    Operation
    Size zip
    Size 163.9 KB
    Date 4/6/10
    Files in document
    pdf
    74.7 KB
    zip
    89.1 KB
    Description
    Operation
    Size pdf
    Size 172 KB
    Date 4/6/10
    Description
    Installation
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    EoLi - Basic Rack PDUs (Version 1)
    Description
    End of Life Instruction (EoLI) for the Basic Rack PDU Product Range
    Size pdf
    Size 676.2 KB
    Date 1/28/19
    Description
    End of Life Instruction (EoLI) for the Basic Rack PDU Product Range
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    ePEP - Basic Rack PDUs (Version 0)
    Files in document
    pdf
    415.3 KB
    pdf
    415.3 KB
    Description
    Product Environmental Profile (ePEP) for the Basic Rack PDU Product Range
    Size zip
    Size 830.5 KB
    Date 8/6/12
    Files in document
    pdf
    415.3 KB
    pdf
    415.3 KB
    Description
    Product Environmental Profile (ePEP) for the Basic Rack PDU Product Range
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /