variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1

Show more characteristics
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price*
    1,212.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Altivar Process ATV600
    product or component type
    Variable speed drive
    product specific application
    Process and utilities
    device short name
    ATV630
    variant
    Standard version
    product destination
    Synchronous motors
    Asynchronous motors
    mounting mode
    Wall mount
    EMC filter
    Without EMC filter
    IP degree of protection
    IP21IEC 61800-5-1
    IP21IEC 60529
    degree of protection
    UL type 1 UL 508C
    type of cooling
    Forced convection
    supply frequency
    50...60 Hz - 5...5 %
    Phase
    3 phase
    [Us] rated supply voltage
    200...240 V - 15...10 %
    motor power kW
    2.2 kW normal duty)
    1.5 kW heavy duty)
    Maximum Horse Power Rating
    3 hp normal duty
    2 hp heavy duty
    line current
    8.4 A 200 V normal duty)
    7.2 A 240 V normal duty)
    6 A 200 V heavy duty)
    5.3 A 240 V heavy duty)
    prospective line Isc
    50 kA
    apparent power
    3 kVA 240 V normal duty)
    2.2 kVA 240 V heavy duty)
    continuous output current
    11.2 A 4 kHz normal duty
    8 A 4 kHz heavy duty
    maximum transient current
    12 A 60 s heavy duty)
    12.3 A 60 s normal duty)
    asynchronous motor control profile
    Variable torque standard
    Constant torque standard
    Optimized torque mode
    synchronous motor control profile
    Permanent magnet motor
    Synchronous reluctance motor
    output frequency
    0.0001…0.5 kHz
    speed drive output frequency
    0.1…599 Hz
    nominal switching frequency
    4 kHz
    switching frequency
    2...12 kHz adjustable
    4...12 kHz with derating factor
    safety function
    STO (safe torque off) SIL 3
    discrete input logic
    16 preset speeds
    communication port protocol
    Ethernet
    Modbus serial
    Modbus TCP
    option card
    Slot A communication module, Profibus DP V1
    Slot A communication module, Profinet
    Slot A communication module, DeviceNet
    Slot A communication module, Modbus TCP/EtherNet/IP
    Slot A communication module, CANopen daisy chain RJ45
    Slot A communication module, CANopen SUB-D 9
    Slot A communication module, CANopen screw terminals
    Slot A/slot B digital and analog I/O extension module
    Slot A/slot B output relay extension module
    Slot A communication module, Ethernet IP/Modbus TCP/MD-Link
    communication module, BACnet MS/TP
    communication module, Ethernet Powerlink
    Complementary
    output voltage
    <= power supply voltage
    permissible temporary current boost
    1.1 x In 60 s normal duty)
    1.5 x In 60 s heavy duty)
    motor slip compensation
    Automatic whatever the load
    Not available in permanent magnet motor law
    Can be suppressed
    Adjustable
    acceleration and deceleration ramps
    Linear adjustable separately from 0.01...9999 s
    braking to standstill
    By DC injection
    protection type
    Thermal protection motor
    Safe torque off motor
    Motor phase break motor
    Thermal protection drive
    Safe torque off drive
    Overheating drive
    Overcurrent between output phases and earth drive
    Overload of output voltage drive
    Short-circuit protection drive
    Motor phase break drive
    Overvoltages on the DC bus drive
    Line supply overvoltage drive
    Line supply undervoltage drive
    Line supply phase loss drive
    Overspeed drive
    Break on the control circuit drive
    frequency resolution
    Display unit 0.1 Hz
    Analog input 0.012/50 Hz
    electrical connection
    Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
    Motor screw terminal 2.5...6 mm² AWG 14...AWG 10
    Line side screw terminal 2.5...6 mm² AWG 14...AWG 10
    connector type
    RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
    RJ45 on the remote graphic terminal)Modbus serial
    physical interface
    2-wire RS 485 Modbus serial
    transmission frame
    RTU Modbus serial
    transmission rate
    10/100 Mbit/s Ethernet IP/Modbus TCP
    4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
    exchange mode
    Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
    data format
    8 bits, configurable odd, even or no parity Modbus serial
    type of polarization
    No impedance Modbus serial
    number of addresses
    1…247 Modbus serial
    method of access
    Slave Modbus TCP
    supply
    External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and short-circuit protection
    Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
    Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection
    local signalling
    Local diagnostic 3 LEDs
    Embedded communication status 3 LEDs dual colour)
    Communication module status 4 LEDs dual colour)
    Presence of voltage 1 LED red)
    width
    5.67 in (144 mm)
    height
    13.78 in (350 mm)
    depth
    7.99 in (203 mm)
    net weight
    9.92 lb(US) (4.5 kg)
    analogue input number
    3
    analogue input type
    AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits
    AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
    discrete input number
    8
    discrete input type
    DI1...DI6 programmable, 24 V DC <= 30 V)3.5 kOhm
    DI5, DI6 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
    STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
    input compatibility
    DI1...DI6 discrete input level 1 PLC EN/IEC 61131-2
    DI5, DI6 discrete input level 1 PLC IEC 65A-68
    STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
    discrete input logic
    Positive logic (source) DI1...DI6), < 5 V, > 11 V
    Negative logic (sink) DI1...DI6), > 16 V, < 10 V
    Positive logic (source) DI5, DI6), < 0.6 V, > 2.5 V
    Positive logic (source) STOA, STOB), < 5 V, > 11 V
    analogue output number
    2
    analogue output type
    Software-configurable voltage AO1, AO2 0...10 V DC 470 Ohm 10 bits
    Software-configurable current AO1, AO2 0...20 mA 10 bits
    sampling duration
    2 ms +/- 0.5 ms DI1...DI4) - discrete input
    5 ms +/- 1 ms DI5, DI6) - discrete input
    5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input
    10 ms +/- 1 ms AO1) - analog output
    accuracy
    +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
    +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
    linearity error
    AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
    AO1, AO2 +/- 0.2 % analog output
    relay output number
    3
    relay output type
    Configurable relay logic R1 fault relay NO/NC 100000 cycles
    Configurable relay logic R2 sequence relay NO 100000 cycles
    Configurable relay logic R3 sequence relay NO 100000 cycles
    refresh time
    Relay output R1, R2, R3)5 ms +/- 0.5 ms)
    minimum switching current
    Relay output R1, R2, R3 5 mA 24 V DC
    maximum switching current
    Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC
    Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC
    Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
    Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
    isolation
    Between power and control terminals
    Variable speed drive application selection
    Compressor centrifugal Building - HVAC
    Other application Food and beverage processing
    Fan Mining mineral and metal
    Pump Mining mineral and metal
    Fan Oil and gas
    Other application Water and waste water
    Screw compressor Building - HVAC
    Pump Food and beverage processing
    Fan Food and beverage processing
    Atomization Food and beverage processing
    Electro submersible pump (ESP) Oil and gas
    Water injection pump Oil and gas
    Jet fuel pump Oil and gas
    Compressor for refinery Oil and gas
    Centrifuge pump Water and waste water
    Positive displacement pump Water and waste water
    Electro submersible pump (ESP) Water and waste water
    Screw pump Water and waste water
    Lobe compressor Water and waste water
    Screw compressor Water and waste water
    Compressor centrifugal Water and waste water
    Fan Water and waste water
    Conveyor Water and waste water
    Mixer Water and waste water
    Motor power range AC-3
    2.2…3 kW 200…240 V 3 phase
    Environment
    insulation resistance
    > 1 MOhm 500 V DC for 1 minute to earth
    noise level
    54.5 dB 86/188/EEC
    power dissipation in W
    Natural convection 32 W 200 V 4 kHz
    Forced convection 74 W 200 V 4 kHz
    volume of cooling air
    10038.72 Gal/hr(US) (38 m3/h)
    operating position
    Vertical +/- 10 degree
    maximum THDI
    <48 % full load IEC 61000-3-12
    electromagnetic compatibility
    Electrostatic discharge immunity test level 3 IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
    Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
    1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5
    Conducted radio-frequency immunity test level 3 IEC 61000-4-6
    pollution degree
    2 EN/IEC 61800-5-1
    vibration resistance
    1.5 mm peak to peak 2…13 Hz)IEC 60068-2-6
    1 gn 13…200 Hz)IEC 60068-2-6
    shock resistance
    15 gn 11 ms IEC 60068-2-27
    relative humidity
    5…95 % without condensation IEC 60068-2-3
    ambient air temperature for operation
    5…122 °F (-15…50 °C) without)
    122…140 °F (50…60 °C) with derating factor)
    ambient air temperature for storage
    -40…158 °F (-40…70 °C)
    operating altitude
    <= 3280.84 ft (1000 m) without
    1000...4800 m with current derating 1 % per 100 m
    environmental characteristic
    Chemical pollution resistance class 3C3 EN/IEC 60721-3-3
    Dust pollution resistance class 3S3 EN/IEC 60721-3-3
    standards
    UL 508C
    EN/IEC 61800-3
    Environment 1 category C2 EN/IEC 61800-3
    Environment 2 category C3 EN/IEC 61800-3
    EN/IEC 61800-5-1
    IEC 61000-3-12
    IEC 60721-3
    IEC 61508
    IEC 13849-1
    product certifications
    ATEX INERIS
    ATEX zone 2/22
    CSA
    DNV-GL
    TÜV
    UL
    REACH
    marking
    CE
    Ordering and shipping details
    Category
    22205 - ATV630 FRAMES 1 & 2
    Discount Schedule
    CP4E
    GTIN
    00785901967439
    Package weight(Lbs)
    5.96 kg (13.14 lb(US))
    Returnability
    Yes
    Country of origin
    ID
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • View more View less

    Documents

    Language
    • All Languages38
    • English38
    • Chinese9
    • French9
    • Spanish9
    Catalog
    Format
    Size
    Date
    Add to My Documents
    Digest 178 Catalog 26: AC Drives and Soft Starters (Version 1.0)
    Description
    Digest 178 Catalog Section 26: Selection information for open AC drives, AC soft starters, enclosed soft starters and general information for AC drives support, training, and documentation. Replaces Digest 177 section 26; 0100CT1501_SEC-26
    Size pdf
    Size 2.8 MB
    Date 5/12/19
    Description
    Digest 178 Catalog Section 26: Selection information for open AC drives, AC soft starters, enclosed soft starters and general information for AC drives support, training, and documentation. Replaces Digest 177 section 26; 0100CT1501_SEC-26
    User guide
    Format
    Size
    Date
    Add to My Documents
    ATV600 Embedded Safety function manual (Version 08)
    Description
    ATV630, ATV650, ATV660, ATV680Altivar Process Modular
    Size pdf
    Size 970.6 KB
    Date 8/1/19
    Description
    ATV630, ATV650, ATV660, ATV680Altivar Process Modular
    Size pdf
    Size 2.6 MB
    Date 6/5/19
    ATV600 - Communication parameters addresses V2.5 (Version 2.5)
    Description
    fieldbus addresses to use with each Fieldbus manuals
    Size xlsx
    Size 258.6 KB
    Date 5/16/19
    Description
    fieldbus addresses to use with each Fieldbus manuals
    3) ATV600 Programming manual (V2.5) (Version 08)
    Description
    ATV630, ATV650, ATV660, ATV680
    Size pdf
    Size 9.5 MB
    Date 5/14/19
    Description
    ATV630, ATV650, ATV660, ATV680
    2) ATV630-650 Installation manual (Version 09)
    Description
    ATV630, ATV650
    Size pdf
    Size 6 MB
    Date 3/19/19
    Description
    ATV630, ATV650
    1) ATV630/ATV650 Getting started Annex: SCCR (Version 11)
    Description
    Short-Circuit Current Ratings (SCCR) and Branch Circuit ProtectionAltivar Process
    Size pdf
    Size 193.4 KB
    Date 3/1/19
    Description
    Short-Circuit Current Ratings (SCCR) and Branch Circuit ProtectionAltivar Process
    Size pdf
    Size 1.1 MB
    Date 10/30/18
    1) ATV630/ATV650 Getting Started User Guide (Version 03)
    Description
    Getting Started with Altivar Process ATV600 ATV630/ATV650
    Size pdf
    Size 1.8 MB
    Date 11/30/17
    Description
    Getting Started with Altivar Process ATV600 ATV630/ATV650
    ATV600 EthernetIP/Modbus TCP Manual: VW3A3720, VW3A3721 (Version 03)
    Description
    VW3A3720 = For ATV600 firmware V1.5 and upper VW3A3721 = For ATV600 firmware V1.6 and upper
    Size pdf
    Size 2.4 MB
    Date 10/31/17
    Description
    VW3A3720 = For ATV600 firmware V1.5 and upper VW3A3721 = For ATV600 firmware V1.6 and upper
    Size pdf
    Size 1.3 MB
    Date 10/31/17
    ATV600 & ATV900 ATEX manual (Version 03)
    Description
    ATV630, 650, 660 & 680, ATV930, 950, 960 & 980 Altivar Process Modular
    Size pdf
    Size 1.5 MB
    Date 4/28/17
    Description
    ATV630, 650, 660 & 680, ATV930, 950, 960 & 980 Altivar Process Modular
    Size pdf
    Size 5.2 MB
    Date 4/27/17
    Size pdf
    Size 3.5 MB
    Date 8/31/16
    Size pdf
    Size 1.8 MB
    Date 8/7/15
    Size pdf
    Size 2.3 MB
    Date 4/8/15
    Size pdf
    Size 5 MB
    Date 11/27/14
    3) ATV600 guide de programmation (Version 05)
    Description
    ATV630, ATV650, ATV660, ATV680
    Size pdf
    Size 7.8 MB
    Date 5/31/18
    Description
    ATV630, ATV650, ATV660, ATV680
    3) ATV600 Manual de programación (Version 05)
    Description
    ATV630, ATV650, ATV660, ATV680
    Size pdf
    Size 9.6 MB
    Date 5/31/18
    Description
    ATV630, ATV650, ATV660, ATV680
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD file (on TraceParts) for ATV630U22M3: variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1 (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for ATV630U22M3: variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1 (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    CAD for ATV630U22M3: variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1 (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    CAD for ATV630U22M3: variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1 (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    Certificate
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 77.6 KB
    Date 1/31/19
    Size pdf
    Size 974.1 KB
    Date 7/3/14
    Instruction Sheet
    Format
    Size
    Date
    Add to My Documents
    ATV IS EMC_plate : VW3A47801 to 05 (Version 00)
    Description
    ATV600, ATV900 : Frame sizes 1 to 5 ATV340 : Frame sizes 4 & 5
    Size pdf
    Size 9.2 MB
    Date 9/25/18
    Description
    ATV600, ATV900 : Frame sizes 1 to 5 ATV340 : Frame sizes 4 & 5
    Instruction Sheet - Size7 Flange Mounting Kit - VW3A9510...515 (Version 04)
    Description
    VW3A9510, VW3A9511, VW3A9512, VW3A9513, VW3A9514, VW3A9515
    Size pdf
    Size 2.1 MB
    Date 2/1/19
    Description
    VW3A9510, VW3A9511, VW3A9512, VW3A9513, VW3A9514, VW3A9515
    Size pdf
    Size 404.5 KB
    Date 11/12/15
    Application solutions
    Format
    Size
    Date
    Add to My Documents
    Application Note: ATV600 Multi-Masters Booster Control with Pressure Feedback & Service Continuity, (Version 1.0)
    Description
    how to configure a Multi Masters Booster Control with Service Continuity. Booster Control is used to maintain a constant pressure at the outlet by varying the speed of the pumps. Altivar Process ATV600 drives allow these pumps to have an optimized consumption of the power and at the same time provide optimized monitoring features.
    Size pdf
    Size 2.2 MB
    Date 1/12/17
    Description
    how to configure a Multi Masters Booster Control with Service Continuity. Booster Control is used to maintain a constant pressure at the outlet by varying the speed of the pumps. Altivar Process ATV600 drives allow these pumps to have an optimized consumption of the power and at the same time provide optimized monitoring features.
    Application Note: ATV600 Multi-Drives Standard Level Control (Version 1.0)
    Description
    Application Note: how to configure a Multi-Drives Standard Level Control
    Size pdf
    Size 2 MB
    Date 1/12/17
    Description
    Application Note: how to configure a Multi-Drives Standard Level Control
    Application Note: ATV600 Multi-Drives with Booster Control Optimized (Version 1.0)
    Description
    Application Note: How to configure a Multi-Drives Booster Control Optimized
    Size pdf
    Size 2 MB
    Date 1/12/17
    Description
    Application Note: How to configure a Multi-Drives Booster Control Optimized
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1
    Description
    variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1
    Size pdf
    Size 195.3 KB
    Date 12/16/19
    Description
    variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1
    Description
    variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1
    Size pdf
    Size 195.3 KB
    Date 12/16/19
    Description
    variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    Instruction Sheet: China RoHS - Hazardous Substances Table (Version 01)
    Description
    This table is made according to SJ/T 11364. O: indicates that the concentration of hazardous substance in all of the homogeneous materials for this part is below the limit as stipulated in GB/T 26572. X: indicates that concentration of hazardous substance in at least one of the homogeneous materials used for this part is above the limit as stipulated in GB/T 26572
    Size pdf
    Size 1.1 MB
    Date 5/30/16
    Description
    This table is made according to SJ/T 11364. O: indicates that the concentration of hazardous substance in all of the homogeneous materials for this part is below the limit as stipulated in GB/T 26572. X: indicates that concentration of hazardous substance in at least one of the homogeneous materials used for this part is above the limit as stipulated in GB/T 26572
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1
    Description
    variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1
    Size pdf
    Size 195.3 KB
    Date 12/16/19
    Description
    variable speed drive ATV630 - 2.2kW/3HP - 200...240V - IP21/UL type 1
  • View more View less

    Software and Firmware

    Language
    • All Languages10
    • English12
    • Bulgarian3
    • Chinese3
    • Czech3
    • Danish3
    • Dutch3
    • Finnish3
    • French3
    • German3
    • Greek3
    • Hungarian3
    • Italian3
    • Korean3
    • Norwegian3
    • Polish3
    • Portuguese3
    • Russian3
    • Slovak3
    • Spanish3
    • Swedish3
    • Turkish3
    Software - Released
    Format
    Size
    Date
    Add to My Documents
    DTM files
    Format
    Size
    Date
    Add to My Documents
    Altivar Process ATV6xx DTM Library (Version 2.5.1)
    Files in document
    Description
    The DTM libraries are installed individually, independently of the FDT container.The DTMs can be used in Schneider Electric environments:- SoMove- Unity (Device-dependant)- SoMachine (Device-dependant) For other Languages, you can download a dedicated EXE file on https://www.se.com/ww/en/product-range/2714-somoveALWAYS INSTALL FIRST THE ENGLISH EXE
    Size zip
    Size 85.2 MB
    Date 5/16/19
    Files in document
    Description
    The DTM libraries are installed individually, independently of the FDT container.The DTMs can be used in Schneider Electric environments:- SoMove- Unity (Device-dependant)- SoMachine (Device-dependant) For other Languages, you can download a dedicated EXE file on https://www.se.com/ww/en/product-range/2714-somoveALWAYS INSTALL FIRST THE ENGLISH EXE
    EDS Files
    Format
    Size
    Date
    Add to My Documents
    Size zip
    Size 27.3 KB
    Date 5/16/19
    Size zip
    Size 435.8 KB
    Date 12/20/18
    POWERLINK XDD VW3A3619 (Version 1.2.1)
    Description
    on ATV32, ATV320, ATV340, ATV600, ATV900
    Size zip
    Size 106.6 KB
    Date 12/6/18
    Description
    on ATV32, ATV320, ATV340, ATV600, ATV900
    Size zip
    Size 26.9 KB
    Date 11/6/18
    Size zip
    Size 26.4 KB
    Date 8/31/18
    Size zip
    Size 4 KB
    Date 5/18/18
    Description
    22 feb 2018
    Size zip
    Size 25.9 KB
    Date 4/14/16
    Size zip
    Size 23.2 KB
    Date 4/16/15
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions
    Drives with IP21 Top Cover

    Right and Front Views

    Drives Without IP21 Top Cover

    Left and Rear Views


  • Mounting and Clearance

    Clearances


    X1

    X2

    X3

    ≥ 100 mm (3.94 in.)

    ≥ 100 mm (3.94 in.)

    ≥ 10 mm (0.39 in.)


    Mounting Types
    Mounting Type A: Individual IP21


    a ≥
    100 mm (3.94 in.)

    Mounting Type B: Side by Side IP20


    Mounting Type C: Individual IP20


    a ≥
    0


  • Connections and Schema

    Three-Phase Power Supply with Upstream Breaking via Line Contactor

    Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1


    (1)
    Line choke if used
    (2)
    Use relay R1 set to operating state Fault to switch Off the product once an error is detected.
    A1 :
    Drive
    KM1 :
    Line Contactor
    Q2, Q3 :
    Circuit breakers
    S1, S2 :
    Pushbuttons
    T1 :
    Transformer for control part


    Three-Phase Power Supply with Downstream Breaking via Contactor

    Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1


    (1)
    Line choke if used
    (2)
    Use relay R1 set to operating state Fault to switch Off the product once an error is detected.
    A1 :
    Drive
    KM1 :
    Contactor


    Control Block Wiring Diagram


    (1)
    Safe Torque Off
    (2)
    Analog Output
    (3)
    Digital Input
    (4)
    Reference potentiometer
    (5)
    Analog Input
    R1A, R1B, R1C :
    Fault relay
    R2A, R2C :
    Sequence relay
    R3A, R3C :
    Sequence relay

    Sensor Connection

    It is possible to connect either 1 or 3 sensors on terminals AI2 or AI3.



    Sink / Source Switch Configuration

    The switch is used to adapt the operation of the logic inputs to the technology of the programmable controller outputs.

    • Set the switch to Source (factory setting) if using PLC outputs with PNP transistors.

    • Set the switch to Ext if using PLC outputs with NPN transistors.

    Switch Set to SRC (Source) Position Using the Output Power Supply for the Digital Inputs


    Switch Set to SRC (Source) Position and Use of an External Power Supply for the DIs


    Switch Set to SK (Sink) Position Using the Output Power Supply for the Digital Inputs


    Switch Set to EXT Position Using an External Power Supply for the DIs



  • Performance Curves

    Derating Curves


    40 °C (104 °F) - Mounting type A, B and C
    50 °C (122 °F) - Mounting type A, B and C
    60 °C (140 °F) - Mounting type B and C
    In :
    Nominal Drive Current
    SF :
    Switching Frequency