ATV630U30M3
variable speed drive ATV630 - 3kW - 200...240V - IP21/UL type 1
Show more characteristics-
Product availabilityStock - Normally stocked in distribution facility
-
Characteristics
Main range of product Altivar Process ATV600product or component type Variable speed driveproduct specific application Process and utilitiesdevice short name ATV630variant Standard versionproduct destination Synchronous motorsAsynchronous motorsmounting mode Wall mountEMC filter Without EMC filterIP degree of protection IP21IEC 61800-5-1IP21IEC 60529degree of protection UL type 1 UL 508Ctype of cooling Forced convectionsupply frequency 50...60 Hz - 5...5 %Phase 3 phase[Us] rated supply voltage 200...240 V - 15...10 %motor power kW 3 kW normal duty)2.2 kW heavy duty)Maximum Horse Power Rating 3 hp heavy duty4 hp normal dutyline current 11.5 A 200 V normal duty)9.9 A 240 V normal duty)8.7 A 200 V heavy duty)7.6 A 240 V heavy duty)prospective line Isc 50 kAapparent power 4.1 kVA 240 V normal duty)3.2 kVA 240 V heavy duty)continuous output current 13.7 A 4 kHz normal duty11.2 A 4 kHz heavy dutymaximum transient current 16.8 A 60 s heavy duty)15.1 A 60 s normal duty)asynchronous motor control profile Optimized torque modeVariable torque standardConstant torque standardsynchronous motor control profile Permanent magnet motorSynchronous reluctance motoroutput frequency 0.0001…0.5 kHzspeed drive output frequency 0.1…599 Hznominal switching frequency 4 kHzswitching frequency 2...12 kHz adjustable4...12 kHz with derating factorsafety function STO (safe torque off) SIL 3discrete input logic 16 preset speedscommunication port protocol Modbus TCPEthernetModbus serialoption card Slot A communication module, Profibus DP V1Slot A communication module, ProfinetSlot A communication module, DeviceNetSlot A communication module, Modbus TCP/EtherNet/IPSlot A communication module, CANopen daisy chain RJ45Slot A communication module, CANopen SUB-D 9Slot A communication module, CANopen screw terminalsSlot A/slot B digital and analog I/O extension moduleSlot A/slot B output relay extension moduleSlot A communication module, Ethernet IP/Modbus TCP/MD-Link communication module, BACnet MS/TP communication module, Ethernet PowerlinkComplementary output voltage <= power supply voltagepermissible temporary current boost 1.1 x In 60 s normal duty)1.5 x In 60 s heavy duty)motor slip compensation Can be suppressedAutomatic whatever the loadAdjustableNot available in permanent magnet motor lawacceleration and deceleration ramps Linear adjustable separately from 0.01...9999 sbraking to standstill By DC injectionprotection type Thermal protection motorSafe torque off motorMotor phase break motorThermal protection driveSafe torque off driveOverheating driveOvercurrent between output phases and earth driveOverload of output voltage driveShort-circuit protection driveMotor phase break driveOvervoltages on the DC bus driveLine supply overvoltage driveLine supply undervoltage driveLine supply phase loss driveOverspeed driveBreak on the control circuit drivefrequency resolution Display unit 0.1 HzAnalog input 0.012/50 Hzelectrical connection Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16Motor screw terminal 4...6 mm² AWG 12...AWG 10Line side screw terminal 2.5...6 mm² AWG 14...AWG 10connector type RJ45 on the remote graphic terminal)Ethernet/Modbus TCPRJ45 on the remote graphic terminal)Modbus serialphysical interface 2-wire RS 485 Modbus serialtransmission frame RTU Modbus serialtransmission rate 10/100 Mbit/s Ethernet IP/Modbus TCP4.8, 9.6, 19.2, 38.4 kbit/s Modbus serialexchange mode Half duplex, full duplex, autonegotiation Ethernet/Modbus TCPdata format 8 bits, configurable odd, even or no parity Modbus serialtype of polarization No impedance Modbus serialnumber of addresses 1…247 Modbus serialmethod of access Slave Modbus TCPsupply External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protectionInternal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protectionlocal signalling Local diagnostic 3 LEDsEmbedded communication status 3 LEDs dual colour)Communication module status 4 LEDs dual colour)Presence of voltage 1 LED red)width 5.67 in (144 mm)height 13.78 in (350 mm)depth 7.99 in (203 mm)net weight 9.92 lb(US) (4.5 kg)analogue input number 3analogue input type AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bitsAI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bitsdiscrete input number 8discrete input type DI1...DI6 programmable, 24 V DC <= 30 V)3.5 kOhmDI5, DI6 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhminput compatibility DI1...DI6 discrete input level 1 PLC EN/IEC 61131-2DI5, DI6 discrete input level 1 PLC IEC 65A-68STOA, STOB discrete input level 1 PLC EN/IEC 61131-2discrete input logic Positive logic (source) DI1...DI6), < 5 V, > 11 VNegative logic (sink) DI1...DI6), > 16 V, < 10 VPositive logic (source) DI5, DI6), < 0.6 V, > 2.5 VPositive logic (source) STOA, STOB), < 5 V, > 11 Vanalogue output number 2analogue output type Software-configurable voltage AO1, AO2 0...10 V DC 470 Ohm 10 bitsSoftware-configurable current AO1, AO2 0...20 mA 10 bitssampling duration 2 ms +/- 0.5 ms DI1...DI4) - discrete input5 ms +/- 1 ms DI5, DI6) - discrete input5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input10 ms +/- 1 ms AO1) - analog outputaccuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AO1, AO2 for a temperature variation 60 °C analog outputlinearity error AI1, AI2, AI3 +/- 0.15 % of maximum value analog inputAO1, AO2 +/- 0.2 % analog outputrelay output number 3relay output type Configurable relay logic R1 fault relay NO/NC 100000 cyclesConfigurable relay logic R2 sequence relay NO 100000 cyclesConfigurable relay logic R3 sequence relay NO 100000 cyclesrefresh time Relay output R1, R2, R3)5 ms +/- 0.5 ms)minimum switching current Relay output R1, R2, R3 5 mA 24 V DCmaximum switching current Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V ACRelay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DCRelay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V ACRelay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DCisolation Between power and control terminalsVariable speed drive application selection Building - HVAC Compressor centrifugalFood and beverage processing Other applicationMining mineral and metal FanMining mineral and metal PumpOil and gas FanWater and waste water Other applicationBuilding - HVAC Screw compressorFood and beverage processing PumpFood and beverage processing FanFood and beverage processing AtomizationOil and gas Electro submersible pump (ESP)Oil and gas Water injection pumpOil and gas Jet fuel pumpOil and gas Compressor for refineryWater and waste water Centrifuge pumpWater and waste water Positive displacement pumpWater and waste water Electro submersible pump (ESP)Water and waste water Screw pumpWater and waste water Lobe compressorWater and waste water Screw compressorWater and waste water Compressor centrifugalWater and waste water FanWater and waste water ConveyorWater and waste water MixerMotor power range AC-3 2.2…3 kW 200…240 V 3 phaseEnvironment insulation resistance > 1 MOhm 500 V DC for 1 minute to earthnoise level 54.5 dB 86/188/EECpower dissipation in W Natural convection 34 W 200 V 4 kHzForced convection 104 W 200 V 4 kHzvolume of cooling air 10038.72 Gal/hr(US) (38 m3/h)operating position Vertical +/- 10 degreemaximum THDI <48 % full load IEC 61000-3-12electromagnetic compatibility Electrostatic discharge immunity test level 3 IEC 61000-4-2Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3Electrical fast transient/burst immunity test level 4 IEC 61000-4-41.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5Conducted radio-frequency immunity test level 3 IEC 61000-4-6pollution degree 2 EN/IEC 61800-5-1vibration resistance 1.5 mm peak to peak 2…13 Hz)IEC 60068-2-61 gn 13…200 Hz)IEC 60068-2-6shock resistance 15 gn 11 ms IEC 60068-2-27relative humidity 5…95 % without condensation IEC 60068-2-3ambient air temperature for operation 5…122 °F (-15…50 °C) without)122…140 °F (50…60 °C) with derating factor)ambient air temperature for storage -40…158 °F (-40…70 °C)operating altitude <= 3280.84 ft (1000 m) without1000...4800 m with current derating 1 % per 100 menvironmental characteristic Chemical pollution resistance class 3C3 EN/IEC 60721-3-3Dust pollution resistance class 3S3 EN/IEC 60721-3-3standards UL 508C EN/IEC 61800-3Environment 1 category C2 EN/IEC 61800-3Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1product certifications DNV-GLTÜVATEX zone 2/22ATEX INERISCSAREACHULmarking CEOrdering and shipping details Category 22205 - ATV630 FRAMES 1 & 2Discount Schedule CP4EGTIN 00785901966968Package weight(Lbs) 6.02 kg (13.28 lb(US))Returnability YesCountry of origin IDOffer Sustainability Sustainable offer status Green Premium productCalifornia proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.govREACh Regulation EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. -
View more
Documents
Language- All Languages38
- English38
- Chinese9
- French9
- Spanish9
CatalogFormatSizeAdd to My DocumentsSize pdfSize 12.7 MBDate 12/9/19Digest 178 Catalog 26: AC Drives and Soft Starters (Version 1.0)DescriptionDigest 178 Catalog Section 26: Selection information for open AC drives, AC soft starters, enclosed soft starters and general information for AC drives support, training, and documentation. Replaces Digest 177 section 26; 0100CT1501_SEC-26Size pdfSize 2.8 MBDate 5/12/19DescriptionDigest 178 Catalog Section 26: Selection information for open AC drives, AC soft starters, enclosed soft starters and general information for AC drives support, training, and documentation. Replaces Digest 177 section 26; 0100CT1501_SEC-26User guideFormatSizeAdd to My DocumentsATV600 Embedded Safety function manual (Version 08)DescriptionATV630, ATV650, ATV660, ATV680Altivar Process ModularSize pdfSize 970.6 KBDate 8/1/19DescriptionATV630, ATV650, ATV660, ATV680Altivar Process ModularATV600 - Communication parameters addresses V2.5 (Version 2.5)Descriptionfieldbus addresses to use with each Fieldbus manualsSize xlsxSize 258.6 KBDate 5/16/19Descriptionfieldbus addresses to use with each Fieldbus manuals3) ATV600 Programming manual (V2.5) (Version 08)DescriptionATV630, ATV650, ATV660, ATV680Size pdfSize 9.5 MBDate 5/14/19DescriptionATV630, ATV650, ATV660, ATV6802) ATV630-650 Installation manual (Version 09)DescriptionATV630, ATV650Size pdfSize 6 MBDate 3/19/19DescriptionATV630, ATV6501) ATV630/ATV650 Getting started Annex: SCCR (Version 11)DescriptionShort-Circuit Current Ratings (SCCR) and Branch Circuit ProtectionAltivar ProcessSize pdfSize 193.4 KBDate 3/1/19DescriptionShort-Circuit Current Ratings (SCCR) and Branch Circuit ProtectionAltivar Process1) ATV630/ATV650 Getting Started User Guide (Version 03)DescriptionGetting Started with Altivar Process ATV600 ATV630/ATV650Size pdfSize 1.8 MBDate 11/30/17DescriptionGetting Started with Altivar Process ATV600 ATV630/ATV650ATV600 EthernetIP/Modbus TCP Manual: VW3A3720, VW3A3721 (Version 03)DescriptionVW3A3720 = For ATV600 firmware V1.5 and upper VW3A3721 = For ATV600 firmware V1.6 and upperSize pdfSize 2.4 MBDate 10/31/17DescriptionVW3A3720 = For ATV600 firmware V1.5 and upper VW3A3721 = For ATV600 firmware V1.6 and upperATV600 & ATV900 ATEX manual (Version 03)DescriptionATV630, 650, 660 & 680, ATV930, 950, 960 & 980 Altivar Process ModularSize pdfSize 1.5 MBDate 4/28/17DescriptionATV630, 650, 660 & 680, ATV930, 950, 960 & 980 Altivar Process Modular3) ATV600 guide de programmation (Version 05)DescriptionATV630, ATV650, ATV660, ATV680Size pdfSize 7.8 MBDate 5/31/18DescriptionATV630, ATV650, ATV660, ATV6803) ATV600 Manual de programación (Version 05)DescriptionATV630, ATV650, ATV660, ATV680Size pdfSize 9.6 MBDate 5/31/18DescriptionATV630, ATV650, ATV660, ATV680CADFormatSizeAdd to My DocumentsCAD file (on TraceParts) for ATV630U30M3: variable speed drive ATV630 - 3kW - 200...240V - IP21/UL type 1 (Version 2.0)DescriptionYou will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.CAD file (on TraceParts) for ATV630U30M3: variable speed drive ATV630 - 3kW - 200...240V - IP21/UL type 1 (Version 2.0)DescriptionYou will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.CAD for ATV630U30M3: variable speed drive ATV630 - 3kW - 200...240V - IP21/UL type 1 (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD for ATV630U30M3: variable speed drive ATV630 - 3kW - 200...240V - IP21/UL type 1 (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CertificateFormatSizeAdd to My DocumentsInstruction SheetFormatSizeAdd to My DocumentsSize pdfSize 2.5 MBDate 4/24/19ATV IS EMC_plate : VW3A47801 to 05 (Version 00)DescriptionATV600, ATV900 : Frame sizes 1 to 5 ATV340 : Frame sizes 4 & 5Size pdfSize 9.2 MBDate 9/25/18DescriptionATV600, ATV900 : Frame sizes 1 to 5 ATV340 : Frame sizes 4 & 5Instruction Sheet - Size7 Flange Mounting Kit - VW3A9510...515 (Version 04)DescriptionVW3A9510, VW3A9511, VW3A9512, VW3A9513, VW3A9514, VW3A9515Size pdfSize 2.1 MBDate 2/1/19DescriptionVW3A9510, VW3A9511, VW3A9512, VW3A9513, VW3A9514, VW3A9515Size pdfSize 5.1 MBDate 1/31/17Size pdfSize 13.5 MBDate 1/2/17Application solutionsFormatSizeAdd to My DocumentsSize pdfSize 938.5 KBDate 6/18/18Application Note: ATV600 Multi-Drives with Booster Control Optimized (Version 1.0)DescriptionApplication Note: How to configure a Multi-Drives Booster Control OptimizedSize pdfSize 2 MBDate 1/12/17DescriptionApplication Note: How to configure a Multi-Drives Booster Control OptimizedApplication Note: ATV600 Multi-Drives Standard Level Control (Version 1.0)DescriptionApplication Note: how to configure a Multi-Drives Standard Level ControlSize pdfSize 2 MBDate 1/12/17DescriptionApplication Note: how to configure a Multi-Drives Standard Level ControlApplication Note: ATV600 Multi-Masters Booster Control with Pressure Feedback & Service Continuity, (Version 1.0)Descriptionhow to configure a Multi Masters Booster Control with Service Continuity. Booster Control is used to maintain a constant pressure at the outlet by varying the speed of the pumps. Altivar Process ATV600 drives allow these pumps to have an optimized consumption of the power and at the same time provide optimized monitoring features.Size pdfSize 2.2 MBDate 1/12/17Descriptionhow to configure a Multi Masters Booster Control with Service Continuity. Booster Control is used to maintain a constant pressure at the outlet by varying the speed of the pumps. Altivar Process ATV600 drives allow these pumps to have an optimized consumption of the power and at the same time provide optimized monitoring features.China RoHS declarationFormatSizeAdd to My DocumentsATV630U30M3_ROHS_CHINA_DECLARATIONDescriptionATV630U30M3_ROHS_CHINA_DECLARATIONSize pdfSize 195.3 KBDate 12/15/19DescriptionATV630U30M3_ROHS_CHINA_DECLARATIONEU RoHS DeclarationFormatSizeAdd to My DocumentsATV630U30M3_ROHS_DECLARATIONDescriptionATV630U30M3_ROHS_DECLARATIONSize pdfSize 195.3 KBDate 12/15/19DescriptionATV630U30M3_ROHS_DECLARATIONProduct Environmental ProfileFormatSizeAdd to My DocumentsInstruction Sheet: China RoHS - Hazardous Substances Table (Version 01)DescriptionThis table is made according to SJ/T 11364. O: indicates that the concentration of hazardous substance in all of the homogeneous materials for this part is below the limit as stipulated in GB/T 26572. X: indicates that concentration of hazardous substance in at least one of the homogeneous materials used for this part is above the limit as stipulated in GB/T 26572Size pdfSize 1.1 MBDate 5/30/16DescriptionThis table is made according to SJ/T 11364. O: indicates that the concentration of hazardous substance in all of the homogeneous materials for this part is below the limit as stipulated in GB/T 26572. X: indicates that concentration of hazardous substance in at least one of the homogeneous materials used for this part is above the limit as stipulated in GB/T 26572REACh DeclarationFormatSizeAdd to My DocumentsATV630U30M3_REACH_DECLARATIONDescriptionATV630U30M3_REACH_DECLARATIONSize pdfSize 195.3 KBDate 12/15/19DescriptionATV630U30M3_REACH_DECLARATION -
View more
Software and Firmware
Language- All Languages10
- English12
- Bulgarian3
- Chinese3
- Czech3
- Danish3
- Dutch3
- Finnish3
- French3
- German3
- Greek3
- Hungarian3
- Italian3
- Korean3
- Norwegian3
- Polish3
- Portuguese3
- Russian3
- Slovak3
- Spanish3
- Swedish3
- Turkish3
Software - ReleasedFormatSizeAdd to My DocumentsSize zipSize 4.8 MBDate 10/1/19Files in documentDTM filesFormatSizeAdd to My DocumentsAltivar Process ATV6xx DTM Library (Version 2.5.1)Files in documentDescriptionThe DTM libraries are installed individually, independently of the FDT container.The DTMs can be used in Schneider Electric environments:- SoMove- Unity (Device-dependant)- SoMachine (Device-dependant) For other Languages, you can download a dedicated EXE file on https://www.se.com/ww/en/product-range/2714-somoveALWAYS INSTALL FIRST THE ENGLISH EXESize zipSize 85.2 MBDate 5/16/19Files in documentDescriptionThe DTM libraries are installed individually, independently of the FDT container.The DTMs can be used in Schneider Electric environments:- SoMove- Unity (Device-dependant)- SoMachine (Device-dependant) For other Languages, you can download a dedicated EXE file on https://www.se.com/ww/en/product-range/2714-somoveALWAYS INSTALL FIRST THE ENGLISH EXEEDS FilesFormatSizeAdd to My DocumentsPOWERLINK XDD VW3A3619 (Version 1.2.1)Descriptionon ATV32, ATV320, ATV340, ATV600, ATV900Size zipSize 106.6 KBDate 12/6/18Descriptionon ATV32, ATV320, ATV340, ATV600, ATV900Ethernet_EDS_VW3A3720-21_IE13 (Version 1.8)Description22 feb 2018Size zipSize 4 KBDate 5/18/18Description22 feb 2018 -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
DimensionsDrives with IP21 Top CoverRight and Front Views
Drives Without IP21 Top CoverLeft and Rear Views
-
Mounting and Clearance
ClearancesX1
X2
X3
≥ 100 mm (3.94 in.)
≥ 100 mm (3.94 in.)
≥ 10 mm (0.39 in.)
Mounting TypesMounting Type A: Individual IP21a ≥100 mm (3.94 in.)Mounting Type B: Side by Side IP20Mounting Type C: Individual IP20a ≥0 -
Connections and Schema
Three-Phase Power Supply with Upstream Breaking via Line ContactorConnection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1
(1)Line choke if used(2)Use relay R1 set to operating state Fault to switch Off the product once an error is detected.A1 :DriveKM1 :Line ContactorQ2, Q3 :Circuit breakersS1, S2 :PushbuttonsT1 :Transformer for control partThree-Phase Power Supply with Downstream Breaking via ContactorConnection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1
(1)Line choke if used(2)Use relay R1 set to operating state Fault to switch Off the product once an error is detected.A1 :DriveKM1 :ContactorControl Block Wiring Diagram(1)Safe Torque Off(2)Analog Output(3)Digital Input(4)Reference potentiometer(5)Analog InputR1A, R1B, R1C :Fault relayR2A, R2C :Sequence relayR3A, R3C :Sequence relaySensor ConnectionIt is possible to connect either 1 or 3 sensors on terminals AI2 or AI3.
Sink / Source Switch ConfigurationThe switch is used to adapt the operation of the logic inputs to the technology of the programmable controller outputs.
Set the switch to Source (factory setting) if using PLC outputs with PNP transistors.
Set the switch to Ext if using PLC outputs with NPN transistors.
Switch Set to SRC (Source) Position Using the Output Power Supply for the Digital InputsSwitch Set to SRC (Source) Position and Use of an External Power Supply for the DIsSwitch Set to SK (Sink) Position Using the Output Power Supply for the Digital InputsSwitch Set to EXT Position Using an External Power Supply for the DIs -
Performance Curves
Derating Curves40 °C (104 °F) - Mounting type A, B and C50 °C (122 °F) - Mounting type A, B and C60 °C (140 °F) - Mounting type B and CIn :Nominal Drive CurrentSF :Switching Frequency