View all
TeSys BV4

BV4T007J

BV4T007J

TeSys BV4 motor circuit protector, inst trip, 7A, 3P, EverLink lugs, hi fault
Show more characteristics
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
-
Product availabilityStock - Normally stocked in distribution facility
-
Characteristics
Main range TeSysproduct name TeSys BV4device short name BV4product or component type Motor Circuit Protectordevice application Motorperformance level High performancepoles description 3Putilisation category Category Atrip unit technology Magneticprotection type Short-circuitLine Rated Current 7 A 104 °F (40 °C)Magnetic setting range 42…98 A 104 °F (40 °C)control type ToggleComplementary [Ue] rated operational voltage 600Y/347 V AC 50/60 Hzmounting mode By clipsBy screwsmounting support 75 mm symmetrical DIN rail35 mm symmetrical DIN railPlatemechanical durability 40000 cycleselectrical durability 40000 cycles AC-3 440 V In/240000 cycles AC-3 440 V Inlocal signalling Presence of auxiliary contacts flag green)number of slots 1 alarm switch fault signalling contact, plug-in1 voltage release electrical remote tripping, plug-in1 auxiliary switch open/close contact, plug-inconnection pitch 1.06 in (27 mm)Electrical Connection 2 EverLink BTR screw connectors 0.00…0.11 in² (1.5…70 mm²) AWG 14...AWG 2/0), solid copper 2 EverLink BTR screw connectors 0.00…0.08 in² (1.5…50 mm²) AWG 6...AWG 1/0), flexible coppertightening torque 44.25 lbf.in (5 N.m) 0.02 in² (10 mm²) AWG 8)79.66 lbf.in (9 N.m) 0.02 in² (16 mm²) AWG 6)wire stripping length 0.79 in (20 mm)height 6.38 in (162 mm)width 3.19 in (81 mm)depth 4.57 in (116 mm)net weight 3.31 lb(US) (1.5 kg)quantity per set 1color Grey RAL 7016)Environment standards CSA C22.2 No 5UL 489product certifications CSAULIP degree of protection IP40 front face IEC 60529IK degree of protection IK07 IEC 62262mechanical robustness Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6Shocks 15 gn 11 ms IEC 60068-2-27Ambient Air Temperature for Operation -13…158 °F (-25…70 °C)ambient air temperature for storage -58…185 °F (-50…85 °C)operating altitude 6561.68 ft (2000 m) without derating> 2000...5000 m with deratingOrdering and shipping details Category 01124 - TESYS BV4 MOTOR CIRCUIT PROTECTORSDiscount Schedule I11GTIN 03606489503666Package weight(Lbs) 1.54 kg (3.4 lb(US))Returnability YesCountry of origin MXOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information.Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. -
View more
Documents
Language- All Languages6
- English6
- Chinese1
- French1
- German1
- Italian1
- Portuguese1
- Russian1
- Spanish1
CatalogFormatSizeAdd to My DocumentsDigest 178 Catalog 18: Contactors and Starters-IEC (Version 1.0)DescriptionSection 18 of Digest 178 provides selection and ordering information for IEC contactors and starters - TeSys K, TeSys D, TeSys F, TeSys U, TeSys GV, and TeSys LS1. Replaces Digest 177 section 18; 0100CT1501_SEC-18Size pdfSize 6.8 MBDate 9/13/19DescriptionSection 18 of Digest 178 provides selection and ordering information for IEC contactors and starters - TeSys K, TeSys D, TeSys F, TeSys U, TeSys GV, and TeSys LS1. Replaces Digest 177 section 18; 0100CT1501_SEC-18TeSys BV4 Motor Circuit Protectors Catalog (Version 1.0)DescriptionThis catalog contains references, characteristics, dimensions, and wiring schematics for TeSys BV4 Motor Circuit Protectors.Size pdfSize 16.2 MBDate 1/29/19DescriptionThis catalog contains references, characteristics, dimensions, and wiring schematics for TeSys BV4 Motor Circuit Protectors.Instruction SheetFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsTeSys BV4 motor circuit protector, inst trip, 7A, 3P, EverLink lugs, hi faultDescriptionTeSys BV4 motor circuit protector, inst trip, 7A, 3P, EverLink lugs, hi faultSize pdfSize 195.3 KBDate 12/15/19DescriptionTeSys BV4 motor circuit protector, inst trip, 7A, 3P, EverLink lugs, hi faultREACh DeclarationFormatSizeAdd to My DocumentsTeSys BV4 motor circuit protector, inst trip, 7A, 3P, EverLink lugs, hi faultDescriptionTeSys BV4 motor circuit protector, inst trip, 7A, 3P, EverLink lugs, hi faultSize pdfSize 195.3 KBDate 12/15/19DescriptionTeSys BV4 motor circuit protector, inst trip, 7A, 3P, EverLink lugs, hi faultChina RoHS declarationFormatSizeAdd to My DocumentsTeSys BV4 motor circuit protector, inst trip, 7A, 3P, EverLink lugs, hi faultDescriptionTeSys BV4 motor circuit protector, inst trip, 7A, 3P, EverLink lugs, hi faultSize pdfSize 195.3 KBDate 12/15/19DescriptionTeSys BV4 motor circuit protector, inst trip, 7A, 3P, EverLink lugs, hi fault -
Technical FAQs