View all
TeSys D, K and SK Control Relays

CA3KN225ED
CA3KN225ED
TeSys K control relay - 2 NO + 2 NC - <= 690 V - 48 V DC standard coil
Show more characteristics
CA3KN225ED has not been replaced. Please contact your customer care center for more information.
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
-
Characteristics
Main range TeSysproduct name TeSys CAKproduct or component type Control relaydevice short name CA3Kcontactor application Control circuitutilisation category AC-15DC-13pole contact composition 2 NO + 2 NC[Ue] rated operational voltage <= 690 V <= 400 Hzcontrol circuit type DC standard[Uc] control circuit voltage 48 V DCComplementary [Ith] conventional free air thermal current 10 A 122 °F (50 °C)Irms rated making capacity 110 A IEC 60947associated fuse rating 10 A gG IEC 6094710 A gG VDE 0660[Ui] rated insulation voltage 690 V IEC 60947 750 V VDE 0110 group C 690 V BS 5424 600 V CSA C22.2 No 14mounting support PlateRailconnections - terminals solder pins 1.5 x 0.9 mmcontrol circuit voltage limits Operational 0.8...1.15 Uc 122 °F (50 °C))Drop-out 0.1...0.75 Uc 122 °F (50 °C))operating time 10 ms coil de-energisation and NO opening30...40 ms coil energisation and NO closing15 ms coil de-energisation and NC closing25...35 ms coil energisation and NC openingmechanical durability 20 Mcyclesmaximum operating rate 10000 cyc/himmunity to microbreaks 2 msinrush power in W 3 W 68 °F (20 °C))hold-in power consumption in W 3 W 68 °F (20 °C)heat dissipation 3 Wminimum switching voltage 17 Vminimum switching current 5 mAnon overlap distance 0.02 in (0.5 mm)insulation resistance > 10 MOhmheight 2.28 in (58 mm)width 1.77 in (45 mm)depth 2.24 in (57 mm)net weight 0.56 lb(US) (0.255 kg)Environment standards BS 5424IEC 60947NF C 63-140VDE 0660product certifications ULCSAIP degree of protection IP2xprotective treatment TC IEC 60068ambient air temperature for operation -13…122 °F (-25…50 °C)ambient air temperature for storage -58…176 °F (-50…80 °C)operating altitude 6561.68 ft (2000 m) withoutflame retardance V1 UL 94Requirement 2 NF F 16-101Requirement 2 NF F 16-102mechanical robustness Vibrations contactor open2 Gn, 5...300 Hz IEC 60068-2-6Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6Shocks contactor open10 Gn for 11 ms IEC 60068-2-27Shocks contactor closed15 Gn for 11 ms IEC 60068-2-27Ordering and shipping details Category 22371-RELAYS, CONTROLDiscount Schedule I12GTIN 03389110484069Package weight(Lbs) 0.56 lb(US) (0.255 kg)Returnability NoOffer Sustainability California proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.govContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages7
- English5
- French3
CatalogFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 7/12/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter B7 Control relays- TeSys SK, K, D (Version 6.0)DescriptionRelays for control of contactor coils or other devices - 2 to 5 contacts - accessories - TeSys SK, K and D familiesSize pdfSize 3.1 MBDate 5/15/19DescriptionRelays for control of contactor coils or other devices - 2 to 5 contacts - accessories - TeSys SK, K and D familiesCatalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Size pdfSize 108.2 MBDate 7/12/19DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Catalogue TeSys 2019 - Chapitre B7 - Contacteurs auxiliaires (Version 4.0)DescriptionPrésentation des contacteurs auxiliaires, relais, des gammes TeSys SK, SKE, K, DSize pdfSize 3.3 MBDate 6/11/19DescriptionPrésentation des contacteurs auxiliaires, relais, des gammes TeSys SK, SKE, K, DCADFormatSizeAdd to My DocumentsCAD for CA3KN225ED: TeSys K control relay - 2 NO + 2 NC - <= 690 V - 48 V DC standard coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD for CA3KN225ED: TeSys K control relay - 2 NO + 2 NC - <= 690 V - 48 V DC standard coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.End of Life InformationFormatSizeAdd to My DocumentsProduct Environmental ProfileFormatSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.