View all
TeSys D, K and SK Control Relays

CA3KN31SD3
CA3KN31SD3
TeSys K control relay - 3 NO + 1 NC - <= 690 V - 72 V DC standard coil
Show more characteristics
CA3KN31SD3 has not been replaced. Please contact your customer care center for more information.
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
-
Characteristics
Main range TeSysproduct name TeSys CAKproduct or component type Control relaydevice short name CA3Kcontactor application Control circuitutilisation category AC-15DC-13pole contact composition 3 NO + 1 NC[Ue] rated operational voltage <= 690 V <= 400 Hzcontrol circuit type DC standard[Uc] control circuit voltage 72 V DCComplementary coil technology Built-in bidirectional peak limiting diode suppressor[Ith] conventional free air thermal current 10 A 122 °F (50 °C)Irms rated making capacity 110 A IEC 60947associated fuse rating 10 A gG IEC 6094710 A gG VDE 0660[Ui] rated insulation voltage 690 V IEC 60947 750 V VDE 0110 group C 690 V BS 5424 600 V CSA C22.2 No 14mounting support RailPlateconnections - terminals screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible with cable end screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible without cable endtightening torque 11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm 11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 0.24 in (6 mm)control circuit voltage limits Operational 0.8...1.15 Uc 122 °F (50 °C))Drop-out 0.1...0.75 Uc 122 °F (50 °C))operating time 10 ms coil de-energisation and NO opening30...40 ms coil energisation and NO closing15 ms coil de-energisation and NC closing25...35 ms coil energisation and NC openingmechanical durability 20 Mcyclesmaximum operating rate 10000 cyc/himmunity to microbreaks 2 msinrush power in W 3 W 68 °F (20 °C))hold-in power consumption in W 3 W 68 °F (20 °C)heat dissipation 3 Wminimum switching voltage 17 Vminimum switching current 5 mAnon overlap distance 0.02 in (0.5 mm)insulation resistance > 10 MOhmheight 2.28 in (58 mm)width 1.77 in (45 mm)depth 2.24 in (57 mm)net weight 0.50 lb(US) (0.225 kg)Environment standards BS 5424IEC 60947NF C 63-140VDE 0660product certifications CSAULIP degree of protection IP2xprotective treatment TC IEC 60068ambient air temperature for operation -13…122 °F (-25…50 °C)ambient air temperature for storage -58…176 °F (-50…80 °C)operating altitude 6561.68 ft (2000 m) withoutflame retardance V1 UL 94Requirement 2 NF F 16-101Requirement 2 NF F 16-102mechanical robustness Vibrations contactor open2 Gn, 5...300 Hz IEC 60068-2-6Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6Shocks contactor open10 Gn for 11 ms IEC 60068-2-27Shocks contactor closed15 Gn for 11 ms IEC 60068-2-27Ordering and shipping details Category 22371-RELAYS, CONTROLDiscount Schedule I12GTIN 03389110518641Package weight(Lbs) 0.50 lb(US) (0.225 kg)Returnability NoContractual warranty Warranty 18 months -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.