USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Select your location
View all Enerlin'X Com'X
Schneider Eletric EBX210 Picture

EBX210

Schneider Eletric EBX210 Picture
EBX210

ComX 210 - data logger - UL

Show more characteristics
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price*
    1,436.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    PowerLogic
    product name
    ComX
    product or component type
    Energy server
    device short name
    ComX 210
    Complementary
    [Us] rated supply voltage
    Main supply 24 V DC
    maximum power consumption in W
    26 W 24 V
    15 W via PoE
    communication network type
    RS485, Modbus serial 1 RJ45
    RS485, Modbus serial terminal block
    Ethernet, PoE 15W (Power over Ethernet) 1 RJ45
    Ethernet, DHCP 1 RJ45
    number of inputs
    6 digital
    2 analog
    discrete input current
    60 mA 12 V DC
    sensor power supply
    24 V DC 50 mA
    analogue input type
    4...20 mA
    Pt 100
    Pt 1000
    0...10 V
    communication gateway
    Ethernet TCP/IP to Modbus
    memory capacity
    128 MB RAM
    256 MB flash
    mounting mode
    Clip-on
    mounting support
    35 mm DIN rail
    product certifications
    CE
    CUL
    C-Tick
    UL
    standards
    EN 61010-1
    UL 508
    EN 60950
    UL 60950
    depth
    2.72 in (69 mm)
    height
    4.29 in (109 mm)
    width
    5.67 in (144 mm)
    net weight
    15.87 oz (450 g)
    local signalling
    LED:power supply
    LED:status GPRS)
    LED:communication Modbus)
    LED:communication Ethernet)
    LED:communication WiFi)
    LED:I/O
    Environment
    relative humidity
    5…95 % 131 °F (55 °C) without condensation
    IP degree of protection
    IP20 terminal block)
    IP40 front face)
    ambient air temperature for operation
    -13…158 °F (-25…70 °C)
    ambient air temperature for storage
    -40…185 °F (-40…85 °C)
    pollution degree
    3
    operating altitude
    6561.68 ft (2000 m)
    Ordering and shipping details
    Category
    09785 - POWERLOGIC SYSTEM CMPNTS
    Discount Schedule
    PL1
    GTIN
    00785901433309
    Package weight(Lbs)
    0.46 kg (1.02 lb(US))
    Returnability
    Yes
    Country of origin
    DE
    Offer Sustainability
    California proposition 65
    WARNING: This product can expose you to chemicals which are known to the State of California to cause Carcinogen and Reproductive harm.For more information go to www.p65warnings.ca.gov
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • View more View less

    Documents

    Language
    • All Languages15
    • English13
    • Chinese2
    • Dutch2
    • French5
    • German2
    • Italian2
    • Portuguese2
    • Russian2
    • Spanish3
    Catalog
    Format
    Size
    Date
    Add to My Documents
    PowerLogic Catalog - 260 pages Web (NO PRINTED VERSION AVAILABLE) (Version 8.4)
    Description
    Note that no printed catalogs are available but all necessary source files, in 14 sections, are available for download from the Shopping Kiosk.
    Size pdf
    Size 12.9 MB
    Date 9/17/19
    Description
    Note that no printed catalogs are available but all necessary source files, in 14 sections, are available for download from the Shopping Kiosk.
    Enerlin'X Digital Solutions for Smart Systems Catalog (Version 00)
    Description
    This catalog provides information on Enerlin'X including EIFE ethernet add-on module for MasterPact MTZ, smart system design, Enerlin'X components for smart systems, Com'X 210/510, FDM128 ethernet displays, FDM121 system displays, IFE system interface, EIFE embedded ethernet interface, Link150 ethernet gateway, commissioning software, and part number selection tables.
    Size pdf
    Size 11.7 MB
    Date 4/2/19
    Description
    This catalog provides information on Enerlin'X including EIFE ethernet add-on module for MasterPact MTZ, smart system design, Enerlin'X components for smart systems, Com'X 210/510, FDM128 ethernet displays, FDM121 system displays, IFE system interface, EIFE embedded ethernet interface, Link150 ethernet gateway, commissioning software, and part number selection tables.
    Size pdf
    Size 4.8 MB
    Date 2/22/18
    User guide
    Format
    Size
    Date
    Add to My Documents
    Com’X 210 Energy Server User manual (Version 13)
    Description
    Com’X 210 Energy Server User manual
    Size pdf
    Size 3.4 MB
    Date 12/1/19
    Description
    Com’X 210 Energy Server User manual
    Com'X 200/210/510 Commissioning Quick Start Guide (Version 01)
    Description
    This guide provides an overview of the commissioning process for a new Com'X 510. These guidelines can help reduce commissioning time by eliminating unnecessary reboots and adding device configuration at the optimal time.
    Size pdf
    Size 421.9 KB
    Date 1/1/17
    Description
    This guide provides an overview of the commissioning process for a new Com'X 510. These guidelines can help reduce commissioning time by eliminating unnecessary reboots and adding device configuration at the optimal time.
    Serveur d’énergie Com’X 210 Manuel de l’utilisateur (Version 12)
    Description
    Serveur d’énergie Com’X 210 Manuel de l’utilisateur
    Size pdf
    Size 3.5 MB
    Date 12/1/19
    Description
    Serveur d’énergie Com’X 210 Manuel de l’utilisateur
    Size pdf
    Size 3.2 MB
    Date 4/30/19
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD file (on TraceParts) for EBX210: ComX 210 - data logger - UL (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for EBX210: ComX 210 - data logger - UL (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    Instruction Sheet
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 4.8 MB
    Date 2/1/17
    EBXA-USB-WIFI Additional Information (Version 00)
    Description
    EBXA-USB-WIFI Additional Information, 253537634-00
    Size pdf
    Size 1.8 MB
    Date 7/1/15
    Description
    EBXA-USB-WIFI Additional Information, 253537634-00
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    EBX210_ROHS_CHINA_DECLARATION
    Description
    EBX210_ROHS_CHINA_DECLARATION
    Size pdf
    Size 195.3 KB
    Date 12/7/19
    Description
    EBX210_ROHS_CHINA_DECLARATION
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    ECDCom'x&accessories-V1 (Version 1.0)
    Description
    EU Declaration of Conformity for Com'X and accessories
    Size pdf
    Size 646.2 KB
    Date 5/6/16
    Description
    EU Declaration of Conformity for Com'X and accessories
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    EBX210_ROHS_DECLARATION
    Description
    EBX210_ROHS_DECLARATION
    Size pdf
    Size 195.3 KB
    Date 12/7/19
    Description
    EBX210_ROHS_DECLARATION
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    EBX210_REACH_DECLARATION
    Description
    EBX210_REACH_DECLARATION
    Size pdf
    Size 195.3 KB
    Date 12/7/19
    Description
    EBX210_REACH_DECLARATION
    Technical leaflet
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 466.7 KB
    Date 4/2/18
  • View more View less

    Software and Firmware

    Language
    • English2
    Firmware - Released
    Format
    Size
    Date
    Add to My Documents
    Com’X 210 - v6.0.7 (Version 1.0)
    Description
    Com’X v6.0.7 supports the following publication platforms:• Energy Operation• Digital Services Platform (DSP)• Comma Separated Values (CSV)
    Size zip
    Size 47.1 MB
    Date 9/18/19
    Description
    Com’X v6.0.7 supports the following publication platforms:• Energy Operation• Digital Services Platform (DSP)• Comma Separated Values (CSV)
    ComX210v2-1-18_Firmware_EBX210 (Version 1.0)
    Description
    Com’X firmware upgrade to address bug fixes.Updates:Com’X 200/210Known Issues:1. After upgrading to V2.1.18 from a previous version, the Com’X occasionally fails to communicate toconfigured Zigbee devices on its first startup. To correct this, cycle the power to the Com’X orpress “Restart” on the Maintenance > System Settings page. This is not a reoccurring issue.2. After upgrading to V2.1.18 from a previous version, measurements selected for publication arecleared. To continue to publish, the measurement selections must be reselected.Corrections:1. Corrected issue where after an upgrade to V2.1.17, the Local IDs defaulted to 1, causing loss ofcommunications to devices.2. Corrected issue where after an upgrade to V2.1.17, changing Local IDs in the Settings > ModbusGateway > Device IDs page caused the device to be removed or communications lost.Com’X 510Corrections:1. Corrected the issue of excessive time to load the Measurement Table for the CM4000 and CM3000variants, which also reduced the gateway bandwidth.2. Corrected issue where the data series in the 4 Weeks over 4 Weeks energy dashboard reportsinaccurate Date/Time values when the time zone is configured with a positive offset.3. Updated the on-board User Manual to the correct 2.1 version.
    Size zip
    Size 40 MB
    Date 1/29/16
    Description
    Com’X firmware upgrade to address bug fixes.Updates:Com’X 200/210Known Issues:1. After upgrading to V2.1.18 from a previous version, the Com’X occasionally fails to communicate toconfigured Zigbee devices on its first startup. To correct this, cycle the power to the Com’X orpress “Restart” on the Maintenance > System Settings page. This is not a reoccurring issue.2. After upgrading to V2.1.18 from a previous version, measurements selected for publication arecleared. To continue to publish, the measurement selections must be reselected.Corrections:1. Corrected issue where after an upgrade to V2.1.17, the Local IDs defaulted to 1, causing loss ofcommunications to devices.2. Corrected issue where after an upgrade to V2.1.17, changing Local IDs in the Settings > ModbusGateway > Device IDs page caused the device to be removed or communications lost.Com’X 510Corrections:1. Corrected the issue of excessive time to load the Measurement Table for the CM4000 and CM3000variants, which also reduced the gateway bandwidth.2. Corrected issue where the data series in the 4 Weeks over 4 Weeks energy dashboard reportsinaccurate Date/Time values when the time zone is configured with a positive offset.3. Updated the on-board User Manual to the correct 2.1 version.
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /