Characteristics
Main range of product Harmony Kproduct or component type Cam switch bodycomponent name K1[Ith] conventional free air thermal current 12 Asub-assembly composition Contact blocks + fixing platecam switch function Stepping switchoff position Without Off positionpoles description 1Pswitching positions Right: 0° - 30° - 60° - 90° - 120° - 150° - 180° - 210° - 240°mounting location Frontfixing mode Ø 22 mm holebezel material PlasticComplementary number of steps 9switching angle 30 °[Ui] rated insulation voltage 690 V 3)IEC 60947-1[Ithe] conventional enclosed thermal current 10 Arated operational power in W 10500 W AC-21, 500 - 660 V 3 phase IEC 947-31100 W AC-3, 230 V 3 phase IEC 947-31500 W AC-23A, 230 V 3 phase IEC 947-31500 W AC-3, 400 V 1 phase IEC 947-31500 W AC-3, 400 V 3 phase IEC 947-31500 W AC-3, 500 V 3 phase IEC 947-31500 W AC-3, 690 V 3 phase IEC 947-32200 W AC-23A, 400 V 3 phase IEC 947-32200 W AC-23A, 500 V 3 phase IEC 947-32200 W AC-23A, 690 V 3 phase IEC 947-34800 W AC-21, 230 V 3 phase IEC 947-3600 W AC-3, 230 V 1 phase IEC 947-38300 W AC-21, 400 V 3 phase IEC 947-3[Ie] rated operational current AC 1.8 A 690 V AC-3 3 phase IEC 947-32.8 A 500 V AC-3 3 phase IEC 947-32.8 A 690 V AC-23A 3 phase IEC 947-33.3 A 400 V AC-3 3 phase IEC 947-33.8 A 500 V AC-23A 3 phase IEC 947-34.6 A 230 V AC-3 3 phase IEC 947-34.8 A 400 V AC-23A 3 phase IEC 947-35.6 A 230 V AC-23A 3 phase IEC 947-31 A 500 V AC-15 IEC 947-5-12 A 400 V AC-15 IEC 947-5-13 A 230 V AC-15 IEC 947-5-1electrical durability 1000000 cycles AC-151000000 cycles AC-21500000 cycles AC-23500000 cycles AC-3maximum operating rate 2.5 cyc/mn AC-212.5 cyc/mn AC-232.5 cyc/mn AC-38.333 cyc/mn AC-15short-circuit current 10000 Ashort-circuit protection 16 A cartridge fuse gG[Uimp] rated impulse withstand voltage 4 kV in isolating function6 kV IEC 947-1contact operation Slow-breakpositive opening Withelectrical connection Captive screw clamp terminals flexible 2 x 1.5 mm²Captive screw clamp terminals solid 1 x 2.5 mm²mechanical durability 1000000 cyclesnet weight 0.41 lb(US) (0.185 kg)Environment standards EN/IEC 60947-3 power circuitEN/IEC 60947-5-1 control circuitCENELEC EN 50013product certifications CSA 240 V 1 hp 1 phaseCSA 240 V 3 hp 3 phase 2UL 240 V 1 hp 3 phaseUL 240 V 0.33 hp 1 phase 2protective treatment TCambient air temperature for operation -13…131 °F (-25…55 °C)ambient air temperature for storage -40…158 °F (-40…70 °C)shock resistance 30 gn IEC 68-2-27vibration resistance 5 gn 10…150 Hz)IEC 68-2-6Ordering and shipping details Category 18406-WORLD SERVICE PARTS(OTHER OP INT)Discount Schedule CS2GTIN 03389110443936Package weight(Lbs) 0.41 lb(US) (0.185 kg)Returnability NoOffer Sustainability Sustainable offer status Green Premium productCalifornia proposition 65 WARNING: This product can expose you to chemicals including: Nickel compounds and Di-isodecyl phthalate (DIDP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.govREACh Regulation REACh free of SVHC YesEU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile No need of specific recycling operationsWEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.Contractual warranty Warranty 18 months -
View more
Documents
Language- English5
CADFormatSizeAdd to My DocumentsCam switches,adaptable sub-assemblies, 12 and 20 A,front mounting,by dia 22 mm hole, bodies (contact blocks + fixing plate) (Version 1.0)Files in documentSize zipSize 74.2 KBDate 11/23/07Files in documentCam switches, adaptable sub-assemblies, 12 and 20 A, bodies (contact blocks + fixing plate), mounting by dia 22 mm hole (Version 1.0)Files in documentSize zipSize 102.2 KBDate 11/23/07Files in documentChina RoHS declarationFormatSizeAdd to My Documentsbody for stepping switch - 1 pole - 30° - 12 A - for Ø 22 mmDescriptionbody for stepping switch - 1 pole - 30° - 12 A - for Ø 22 mmSize pdfSize 195.3 KBDate 12/14/19Descriptionbody for stepping switch - 1 pole - 30° - 12 A - for Ø 22 mmEU RoHS DeclarationFormatSizeAdd to My Documentsbody for stepping switch - 1 pole - 30° - 12 A - for Ø 22 mmDescriptionbody for stepping switch - 1 pole - 30° - 12 A - for Ø 22 mmSize pdfSize 195.3 KBDate 12/14/19Descriptionbody for stepping switch - 1 pole - 30° - 12 A - for Ø 22 mmREACh DeclarationFormatSizeAdd to My Documentsbody for stepping switch - 1 pole - 30° - 12 A - for Ø 22 mmDescriptionbody for stepping switch - 1 pole - 30° - 12 A - for Ø 22 mmSize pdfSize 195.3 KBDate 12/14/19Descriptionbody for stepping switch - 1 pole - 30° - 12 A - for Ø 22 mm -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Body with Plastic BaseFront Mounting by Ø 22 mm/0.87 in. Holea289 mm/3.50 in. -
Technical Description
Link Positions (Factory Mounted)Diagram for 2 to 12-step Stepping SwitchesSelect the number of steps according to the product characteristics.
Angular Position of SwitchSwitching ProgramDiagram for 2 to 12-step Stepping SwitchesSelect the number of steps according to the product characteristics.
Convention Used for Switching Program RepresentationContact closed
Contact closed in 2 positions and maintained between the 2 positions
Sealed assembly for auto-maintain control
Overlapping contacts
Spring return position: for a switching angle of 90°, spring return is over 30° after the last position (for a maximum of 3 simultaneous contacts).
Example: