View all
TeSys D Contactors

LC1D096B7
LC1D096B7
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil
Show more characteristics
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
-
Product availabilityNon-Stock - Not normally stocked in distribution facility
-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Motor controlResistive loadutilisation category AC-4AC-1AC-3poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 HzPower circuit <= 300 V DC[Ie] rated operational current 9 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuitmotor power kW 2.2 kW 220...230 V AC 50/60 Hz AC-3)4 kW 380...400 V AC 50/60 Hz AC-3)4 kW 415...440 V AC 50/60 Hz AC-3)5.5 kW 500 V AC 50/60 Hz AC-3)5.5 kW 660...690 V AC 50/60 Hz AC-3)2.2 kW 400 V AC 50/60 Hz AC-4)motor power HP (UL / CSA) 1 hp 230/240 V AC 50/60 Hz 1 phase2 hp 200/208 V AC 50/60 Hz 3 phase2 hp 230/240 V AC 50/60 Hz 3 phase5 hp 460/480 V AC 50/60 Hz 3 phase7.5 hp 575/600 V AC 50/60 Hz 3 phase0.33 hp 115 V AC 50/60 Hz 1 phasecontrol circuit type AC 50/60 Hz[Uc] control circuit voltage 24 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV IEC 60947overvoltage category III[Ith] conventional free air thermal current 25 A 140 °F (60 °C) power circuit10 A 140 °F (60 °C) signalling circuitIrms rated making capacity 250 A 440 V power circuit IEC 60947140 A AC signalling circuit IEC 60947-5-1250 A DC signalling circuit IEC 60947-5-1rated breaking capacity 250 A 440 V power circuit IEC 60947[Icw] rated short-time withstand current 105 A 104 °F (40 °C) - 10 s power circuit210 A 104 °F (40 °C) - 1 s power circuit30 A 104 °F (40 °C) - 10 min power circuit61 A 104 °F (40 °C) - 1 min power circuit100 A - 1 s signalling circuit120 A - 500 ms signalling circuit140 A - 100 ms signalling circuitassociated fuse rating 10 A gG signalling circuit IEC 60947-5-125 A gG <= 690 V type 1 power circuit20 A gG <= 690 V type 2 power circuitaverage impedance 2.5 mOhm - Ith 25 A 50 Hz power circuit[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1Power circuit 600 V CSAPower circuit 600 V ULSignalling circuit 690 V IEC 60947-1Signalling circuit 600 V CSASignalling circuit 600 V ULelectrical durability 0.6 Mcycles 25 A AC-1 <= 440 V2 Mcycles 9 A AC-3 <= 440 Vpower dissipation per pole 1.56 W AC-10.2 W AC-3safety cover Withmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications CCCCSARINABVGLGOSTULLROS (Lloyds register of shipping)DNVconnections - terminals Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.31 in (8 mm))tightening torque Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 8 mm M3.5Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5operating time 12...22 ms closing4...19 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1mechanical durability 15 Mcyclesmaximum operating rate 3600 cyc/h 140 °F (60 °C)Complementary coil technology Without built-in suppressor modulecontrol circuit voltage limits Drop-out 0.3...0.6 Uc AC 50/60 Hz 140 °F (60 °C))Operational 0.8...1.1 Uc AC 50 Hz 140 °F (60 °C))Operational 0.85...1.1 Uc AC 60 Hz 140 °F (60 °C))inrush power in VA 70 VA 60 Hz 0.75 68 °F (20 °C))70 VA 50 Hz 0.75 68 °F (20 °C))hold-in power consumption in VA 7.5 VA 60 Hz 0.3 68 °F (20 °C))7 VA 50 Hz 0.3 68 °F (20 °C))heat dissipation 2…3 W 50/60 Hzauxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1Mirror contact 1 NC IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA signalling circuitminimum switching voltage 17 V signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm signalling circuitEnvironment IP degree of protection IP20 front face IEC 60529protective treatment TH IEC 60068-2-30pollution degree 3ambient air temperature for operation 23…140 °F (-5…60 °C)ambient air temperature for storage -76…176 °F (-60…80 °C)permissible ambient air temperature around the device -40…158 °F (-40…70 °C) at Ucoperating altitude 9842.52 ft (3000 m) withoutfire resistance 1562 °F (850 °C) IEC 60695-2-1flame retardance V1 UL 94mechanical robustness Vibrations contactor open2 Gn, 5...300 HzVibrations contactor closed4 Gn, 5...300 HzShocks contactor open10 Gn for 11 msShocks contactor closed15 Gn for 11 msheight 3.03 in (77 mm)width 1.77 in (45 mm)depth 3.39 in (86 mm)net weight 0.71 lb(US) (0.32 kg)Ordering and shipping details Category 22354 - CTR,TESYS D,OPEN,9-38A ACDiscount Schedule I12GTIN 00785901272489Package weight(Lbs) 0.33 kg (0.73 lb(US))Returnability NoCountry of origin IDOffer Sustainability Sustainable offer status Green Premium productREACh Regulation REACh free of SVHC YesEU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.Contractual warranty Warranty 18 months -
View more
Documents
Language- All Languages7
- English8
- Chinese4
Data BulletinFormatSizeAdd to My DocumentsMotor Control Solutions for the North American Market (Version 2.0)DescriptionThis bulletin contains information regarding the application of solutions to meet your motor control and protection needs in the US and Canada.Size pdfSize 1.5 MBDate 2/10/17DescriptionThis bulletin contains information regarding the application of solutions to meet your motor control and protection needs in the US and Canada.CADFormatSizeAdd to My DocumentsCAD for LC1D096B7: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD for LC1D096B7: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CertificateFormatSizeAdd to My DocumentsInstruction SheetFormatSizeAdd to My DocumentsSize pdfSize 934.1 KBDate 3/1/17China RoHS declarationFormatSizeAdd to My DocumentsTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coilDescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coilSize pdfSize 195.3 KBDate 12/15/19DescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coilEU RoHS DeclarationFormatSizeAdd to My DocumentsTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coilDescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coilSize pdfSize 195.3 KBDate 12/15/19DescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coilREACh DeclarationFormatSizeAdd to My DocumentsTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coilDescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coilSize pdfSize 195.3 KBDate 12/15/19DescriptionTeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.