View all
TeSys D Contactors

LC1D09P7
LC1D09P7
TeSys D IEC contactor, 9 A, 3 P, 5 HP at 480 VAC, nonreversing, 230 VAC 50/60 Hz coil
Show more characteristics
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
-
Product availabilityStock - Normally stocked in distribution facility
-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Resistive loadMotor controlutilisation category AC-4AC-1AC-3poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 HzPower circuit <= 300 V DC[Ie] rated operational current 9 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuitmotor power kW 2.2 kW 220...230 V AC 50/60 Hz AC-3)4 kW 380...400 V AC 50/60 Hz AC-3)4 kW 415...440 V AC 50/60 Hz AC-3)5.5 kW 500 V AC 50/60 Hz AC-3)5.5 kW 660...690 V AC 50/60 Hz AC-3)2.2 kW 400 V AC 50/60 Hz AC-4)motor power HP (UL / CSA) 1 hp 230/240 V AC 50/60 Hz 1 phase2 hp 200/208 V AC 50/60 Hz 3 phase2 hp 230/240 V AC 50/60 Hz 3 phase5 hp 460/480 V AC 50/60 Hz 3 phase7.5 hp 575/600 V AC 50/60 Hz 3 phase0.33 hp 115 V AC 50/60 Hz 1 phasecontrol circuit type AC 50/60 Hz[Uc] control circuit voltage 230 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV IEC 60947overvoltage category III[Ith] conventional free air thermal current 25 A 140 °F (60 °C) power circuit10 A 140 °F (60 °C) signalling circuitIrms rated making capacity 250 A 440 V power circuit IEC 60947140 A AC signalling circuit IEC 60947-5-1250 A DC signalling circuit IEC 60947-5-1rated breaking capacity 250 A 440 V power circuit IEC 60947[Icw] rated short-time withstand current 105 A 104 °F (40 °C) - 10 s power circuit210 A 104 °F (40 °C) - 1 s power circuit30 A 104 °F (40 °C) - 10 min power circuit61 A 104 °F (40 °C) - 1 min power circuit100 A - 1 s signalling circuit120 A - 500 ms signalling circuit140 A - 100 ms signalling circuitassociated fuse rating 10 A gG signalling circuit IEC 60947-5-125 A gG <= 690 V type 1 power circuit20 A gG <= 690 V type 2 power circuitaverage impedance 2.5 mOhm - Ith 25 A 50 Hz power circuit[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1Power circuit 600 V CSAPower circuit 600 V ULSignalling circuit 690 V IEC 60947-1Signalling circuit 600 V CSASignalling circuit 600 V ULelectrical durability 0.6 Mcycles 25 A AC-1 <= 440 V2 Mcycles 9 A AC-3 <= 440 Vpower dissipation per pole 1.56 W AC-10.2 W AC-3safety cover Withmounting support RailPlatestandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications GOSTBVLROS (Lloyds register of shipping)DNVCSARINACCCULGLconnections - terminals Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable endPower circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable endPower circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable endPower circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable endPower circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable endPower circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable endControl circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable endControl circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable endControl circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable endControl circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable endControl circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable endControl circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable endtightening torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mmPower circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mmControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2operating time 12...22 ms closing4...19 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1mechanical durability 15 Mcyclesmaximum operating rate 3600 cyc/h 140 °F (60 °C)Complementary coil technology Without built-in suppressor modulecontrol circuit voltage limits Drop-out 0.3...0.6 Uc AC 50/60 Hz 140 °F (60 °C))Operational 0.8...1.1 Uc AC 50 Hz 140 °F (60 °C))Operational 0.85...1.1 Uc AC 60 Hz 140 °F (60 °C))inrush power in VA 70 VA 60 Hz 0.75 68 °F (20 °C))70 VA 50 Hz 0.75 68 °F (20 °C))hold-in power consumption in VA 7.5 VA 60 Hz 0.3 68 °F (20 °C))7 VA 50 Hz 0.3 68 °F (20 °C))heat dissipation 2…3 W 50/60 Hzauxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1Mirror contact 1 NC IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA signalling circuitminimum switching voltage 17 V signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm signalling circuitEnvironment IP degree of protection IP20 front face IEC 60529protective treatment TH IEC 60068-2-30pollution degree 3ambient air temperature for operation 23…140 °F (-5…60 °C)ambient air temperature for storage -76…176 °F (-60…80 °C)permissible ambient air temperature around the device -40…158 °F (-40…70 °C) at Ucoperating altitude 9842.52 ft (3000 m) withoutfire resistance 1562 °F (850 °C) IEC 60695-2-1flame retardance V1 UL 94mechanical robustness Vibrations contactor open2 Gn, 5...300 HzVibrations contactor closed4 Gn, 5...300 HzShocks contactor open10 Gn for 11 msShocks contactor closed15 Gn for 11 msheight 3.03 in (77 mm)width 1.77 in (45 mm)depth 3.39 in (86 mm)net weight 0.71 lb(US) (0.32 kg)Ordering and shipping details Category 22354 - CTR,TESYS D,OPEN,9-38A ACDiscount Schedule I12GTIN 00785901564324Package weight(Lbs) 0.36 kg (0.8 lb(US))Returnability YesCountry of origin IDOffer Sustainability Sustainable offer status Green Premium productREACh Regulation REACh free of SVHC YesEU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.Contractual warranty Warranty 18 months -
View more
Documents
Language- All Languages20
- English18
- Chinese4
- French7
CatalogFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 7/12/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter A2 - open, pre-cabled motor starters (Version 6.1)DescriptionFuses- contactors assemblies and circuit breaker-contactors assemblies. Pre-cabled.Size pdfSize 4.1 MBDate 5/15/19DescriptionFuses- contactors assemblies and circuit breaker-contactors assemblies. Pre-cabled.TeSys catalogue - 2019 - 2020 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 7.0)DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesSize pdfSize 12.2 MBDate 5/15/19DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesControl Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Size pdfSize 15 MBDate 3/6/18DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Size pdfSize 108.2 MBDate 7/12/19DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Catalogue TeSys - 2019 - Chapitre A2 - Démarreurs-moteurs nus pré-cablés (Version 4.0)DescriptionEnsembles de démarrage moteur montés sur platine et câblés ou simplement assemblés. Ils comprennent un disjoncteur moteur + contacteur ou fusibles + contacteur. Commande 1, 2 sens de rotation ou démarrage étoile-triangle.Size pdfSize 5.7 MBDate 6/11/19DescriptionEnsembles de démarrage moteur montés sur platine et câblés ou simplement assemblés. Ils comprennent un disjoncteur moteur + contacteur ou fusibles + contacteur. Commande 1, 2 sens de rotation ou démarrage étoile-triangle.Catalogue TeSys 2019 - Chapitre B8 - Contacteurs (Version 4.0)DescriptionPrésentation des gammes de contacteurs TeSys K, D. Gamme de mini contacteurs TeSys SK. Gamme de contacteurs modulaires Tesys GC, contateurs jour/nuit modulaires teSys GY, mini contacteurs modulaires TeSys SKGC, télérupteurs modulaires TeSys GF.Size pdfSize 12.3 MBDate 6/11/19DescriptionPrésentation des gammes de contacteurs TeSys K, D. Gamme de mini contacteurs TeSys SK. Gamme de contacteurs modulaires Tesys GC, contateurs jour/nuit modulaires teSys GY, mini contacteurs modulaires TeSys SKGC, télérupteurs modulaires TeSys GF.Data BulletinFormatSizeAdd to My DocumentsMotor Control Solutions for the North American Market (Version 2.0)DescriptionThis bulletin contains information regarding the application of solutions to meet your motor control and protection needs in the US and Canada.Size pdfSize 1.5 MBDate 2/10/17DescriptionThis bulletin contains information regarding the application of solutions to meet your motor control and protection needs in the US and Canada.CADFormatSizeAdd to My DocumentsSize zipSize 30.3 MBDate 10/3/18Files in documentIEC Contactor, 9-18a, 3 Pole, D-Line (TESYS) (Version 1.2)Files in documentSize zipSize 2.1 MBDate 4/27/09Files in documentCAD for LC1D09P7: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 230 V AC coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD for LC1D09P7: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 230 V AC coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CertificateFormatSizeAdd to My DocumentsInstruction SheetFormatSizeAdd to My DocumentsLC1D 9 to 38 A AC/DC contactors with screw clamp terminals - Instruction Sheet (Version 09)Descriptionw9137830401a55 w91378304 w9137830401 w9137830401a55 w9137830401a55-10 W913783040211A09 W913783040211 W9137830402Size pdfSize 932.9 KBDate 3/1/17Descriptionw9137830401a55 w91378304 w9137830401 w9137830401a55 w9137830401a55-10 W913783040211A09 W913783040211 W9137830402China RoHS declarationFormatSizeAdd to My DocumentsTeSys D IEC contactor, 9 A, 3 P, 5 HP at 480 VAC, nonreversing, 230 VAC 50/60 Hz coilDescriptionTeSys D IEC contactor, 9 A, 3 P, 5 HP at 480 VAC, nonreversing, 230 VAC 50/60 Hz coilSize pdfSize 195.3 KBDate 12/6/19DescriptionTeSys D IEC contactor, 9 A, 3 P, 5 HP at 480 VAC, nonreversing, 230 VAC 50/60 Hz coilDeclaration of conformityFormatSizeAdd to My DocumentsSize pdfSize 303.8 KBDate 6/28/19End of Life InformationFormatSizeAdd to My DocumentsTeSys D Contactors AC 09 to 18A (Version 2.0)DescriptionTeSys D Contactors AC 09 to 18ASize pdfSize 157.9 KBDate 4/28/16DescriptionTeSys D Contactors AC 09 to 18AEU RoHS DeclarationFormatSizeAdd to My DocumentsTeSys D IEC contactor, 9 A, 3 P, 5 HP at 480 VAC, nonreversing, 230 VAC 50/60 Hz coilDescriptionTeSys D IEC contactor, 9 A, 3 P, 5 HP at 480 VAC, nonreversing, 230 VAC 50/60 Hz coilSize pdfSize 195.3 KBDate 12/6/19DescriptionTeSys D IEC contactor, 9 A, 3 P, 5 HP at 480 VAC, nonreversing, 230 VAC 50/60 Hz coilProduct Environmental ProfileFormatSizeAdd to My Documents3P CONT 9A AC3 4KW 1NO 1NC 230VAC COIL (Version 3.0)Description3P CONT 9A AC3 4KW 1NO 1NC 230VAC COILSize pdfSize 132 KBDate 4/28/16Description3P CONT 9A AC3 4KW 1NO 1NC 230VAC COILREACh DeclarationFormatSizeAdd to My DocumentsTeSys D IEC contactor, 9 A, 3 P, 5 HP at 480 VAC, nonreversing, 230 VAC 50/60 Hz coilDescriptionTeSys D IEC contactor, 9 A, 3 P, 5 HP at 480 VAC, nonreversing, 230 VAC 50/60 Hz coilSize pdfSize 195.3 KBDate 12/6/19DescriptionTeSys D IEC contactor, 9 A, 3 P, 5 HP at 480 VAC, nonreversing, 230 VAC 50/60 Hz coil -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Approximate Dimensions