View all
TeSys D Contactors

LC2D129D7
LC2D129D7
TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 42 V AC coil
Show more characteristics
LC2D129D7 has not been replaced. Please contact your customer care center for more information.
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
-
Product availabilityNon-Stock - Not normally stocked in distribution facility
-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Reversing contactordevice short name LC2Dcontactor application Resistive loadMotor controlutilisation category AC-1AC-3device presentation Preassembled with reversing power busbarpoles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 HzPower circuit <= 300 V DC[Ie] rated operational current 25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit12 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuitmotor power kW 3 kW 220...230 V AC 50 Hz5.5 kW 380...400 V AC 50 Hz5.5 kW 415...440 V AC 50 Hz7.5 kW 500 V AC 50 Hz7.5 kW 660...690 V AC 50 Hzmotor power HP (UL / CSA) 1 hp 115 V AC 60 Hz 1 phase2 hp 230/240 V AC 60 Hz 1 phase3 hp 200/208 V AC 60 Hz 3 phase3 hp 230/240 V AC 60 Hz 3 phase7.5 hp 460/480 V AC 60 Hz 3 phase10 hp 575/600 V AC 60 Hz 3 phasecontrol circuit type AC 50/60 Hz[Uc] control circuit voltage 42 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A 140 °F (60 °C) signalling circuit25 A 140 °F (60 °C) power circuitIrms rated making capacity 250 A 440 V power circuit IEC 60947140 A AC signalling circuit IEC 60947-5-1250 A DC signalling circuit IEC 60947-5-1rated breaking capacity 250 A 440 V power circuit IEC 60947[Icw] rated short-time withstand current 30 A 104 °F (40 °C) - 10 min power circuit61 A 104 °F (40 °C) - 1 min power circuit105 A 104 °F (40 °C) - 10 s power circuit210 A 104 °F (40 °C) - 1 s power circuit100 A - 1 s signalling circuit120 A - 500 ms signalling circuit140 A - 100 ms signalling circuitassociated fuse rating 10 A gG signalling circuit IEC 60947-5-140 A gG <= 690 V type 1 power circuit25 A gG <= 690 V type 2 power circuitaverage impedance 2.5 mOhm - Ith 25 A 50 Hz power circuit[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1Power circuit 600 V CSAPower circuit 600 V ULSignalling circuit 690 V IEC 60947-1Signalling circuit 600 V CSASignalling circuit 600 V ULelectrical durability 2 Mcycles 12 A AC-3 <= 440 V0.8 Mcycles 25 A AC-1 <= 440 Vpower dissipation per pole 1.56 W AC-10.36 W AC-3safety cover Withinterlocking type Mechanicalmounting support RailPlatestandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications CSARINAGOSTGLULCCCBVDNVLROS (Lloyds register of shipping)connections - terminals Power circuit Faston terminals 2Control circuit Faston terminals 1operating time 12...22 ms closing4...19 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1mechanical durability 15 Mcyclesmaximum operating rate 3600 cyc/h 140 °F (60 °C)Complementary coil technology Without built-in suppressor modulecontrol circuit voltage limits Drop-out 0.3...0.6 Uc AC 50/60 Hz 140 °F (60 °C))Operational 0.8...1.1 Uc AC 50 Hz 140 °F (60 °C))Operational 0.85...1.1 Uc AC 60 Hz 140 °F (60 °C))inrush power in VA 70 VA 60 Hz 0.75 68 °F (20 °C))70 VA 50 Hz 0.75 68 °F (20 °C))hold-in power consumption in VA 7.5 VA 60 Hz 0.3 68 °F (20 °C))7 VA 50 Hz 0.3 68 °F (20 °C))heat dissipation 2…3 W 50/60 Hzauxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1Mirror contact 1 NC IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA signalling circuitminimum switching voltage 17 V signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm signalling circuitEnvironment IP degree of protection IP20 front face IEC 60529protective treatment TH IEC 60068-2-30pollution degree 3ambient air temperature for operation -4…140 °F (-20…60 °C)ambient air temperature for storage -76…176 °F (-60…80 °C)permissible ambient air temperature around the device -40…158 °F (-40…70 °C) at Ucoperating altitude 9842.52 ft (3000 m) withoutfire resistance 1562 °F (850 °C) IEC 60695-2-1flame retardance V1 UL 94mechanical robustness Vibrations contactor open2 Gn, 5...300 HzVibrations contactor closed4 Gn, 5...300 HzShocks contactor open10 Gn for 11 msShocks contactor closed15 Gn for 11 msheight 3.03 in (77 mm)width 3.54 in (90 mm)depth 3.39 in (86 mm)net weight 1.54 lb(US) (0.697 kg)Ordering and shipping details Category 22354 - CTR,TESYS D,OPEN,9-38A ACDiscount Schedule I12GTIN 03389110664706Package weight(Lbs) 0.73 kg (1.61 lb(US))Returnability NoCountry of origin FRContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages4
- English5
- Chinese4
CADFormatSizeAdd to My DocumentsREVERSING CONTACTOR (Version 1.0)Files in documentSize zipSize 1.1 MBDate 12/18/17Files in documentCertificateFormatSizeAdd to My DocumentsInstruction SheetFormatSizeAdd to My DocumentsLC2 D.. 9 to 38 A reversing contactors with screw clamp terminals - Instruction sheet (Version 07)DescriptionRef on IS: W9 0381941 or W90381941Size pdfSize 850.6 KBDate 6/1/16DescriptionRef on IS: W9 0381941 or W90381941 -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.