View all
TeSys D Contactors

LC2D12JL
LC2D12JL
TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 12 V DC coil
Show more characteristics
LC2D12JL has not been replaced. Please contact your customer care center for more information.
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
-
Product availabilityNon-Stock - Not normally stocked in distribution facility
-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Reversing contactordevice short name LC2Dcontactor application Resistive loadMotor controlutilisation category AC-1AC-3device presentation Preassembled with reversing power busbarpoles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 HzPower circuit <= 300 V DC[Ie] rated operational current 25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit12 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuitmotor power kW 3 kW 220...230 V AC 50 Hz5.5 kW 380...400 V AC 50 Hz5.5 kW 415...440 V AC 50 Hz7.5 kW 500 V AC 50 Hz7.5 kW 660...690 V AC 50 Hzmotor power HP (UL / CSA) 1 hp 115 V AC 60 Hz 1 phase2 hp 230/240 V AC 60 Hz 1 phase3 hp 200/208 V AC 60 Hz 3 phase3 hp 230/240 V AC 60 Hz 3 phase7.5 hp 460/480 V AC 60 Hz 3 phase10 hp 575/600 V AC 60 Hz 3 phasecontrol circuit type DC low consumption[Uc] control circuit voltage 12 V DCauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A 140 °F (60 °C) signalling circuit25 A 140 °F (60 °C) power circuitIrms rated making capacity 250 A 440 V power circuit IEC 60947140 A AC signalling circuit IEC 60947-5-1250 A DC signalling circuit IEC 60947-5-1rated breaking capacity 250 A 440 V power circuit IEC 60947[Icw] rated short-time withstand current 30 A 104 °F (40 °C) - 10 min power circuit61 A 104 °F (40 °C) - 1 min power circuit105 A 104 °F (40 °C) - 10 s power circuit210 A 104 °F (40 °C) - 1 s power circuit100 A - 1 s signalling circuit120 A - 500 ms signalling circuit140 A - 100 ms signalling circuitassociated fuse rating 10 A gG signalling circuit IEC 60947-5-140 A gG <= 690 V type 1 power circuit25 A gG <= 690 V type 2 power circuitaverage impedance 2.5 mOhm - Ith 25 A 50 Hz power circuit[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1Power circuit 600 V CSAPower circuit 600 V ULSignalling circuit 690 V IEC 60947-1Signalling circuit 600 V CSASignalling circuit 600 V ULelectrical durability 2 Mcycles 12 A AC-3 <= 440 V0.8 Mcycles 25 A AC-1 <= 440 Vpower dissipation per pole 1.56 W AC-10.36 W AC-3safety cover Withinterlocking type Mechanicalmounting support RailPlatestandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications CSALROS (Lloyds register of shipping)GOSTULRINAGLCCCDNVBVconnections - terminals Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable endPower circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable endPower circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable endPower circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable endPower circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable endPower circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable endControl circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable endControl circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable endControl circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable endControl circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable endControl circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable endControl circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable endtightening torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mmPower circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mmControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2operating time 65.45...88.55 ms closing20...30 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1mechanical durability 30 Mcyclesmaximum operating rate 3600 cyc/h 140 °F (60 °C)Complementary coil technology Built-in bidirectional peak limiting diode suppressorcontrol circuit voltage limits Drop-out 0.1...0.3 Uc DC 140 °F (60 °C))Operational 0.8...1.25 Uc DC 140 °F (60 °C))time constant 40 msinrush power in W 2.4 W 68 °F (20 °C))hold-in power consumption in W 2.4 W 68 °F (20 °C)auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1Mirror contact 1 NC IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA signalling circuitminimum switching voltage 17 V signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm signalling circuitEnvironment IP degree of protection IP20 front face IEC 60529protective treatment TH IEC 60068-2-30pollution degree 3ambient air temperature for operation -4…140 °F (-20…60 °C)ambient air temperature for storage -76…176 °F (-60…80 °C)permissible ambient air temperature around the device -40…158 °F (-40…70 °C) at Ucoperating altitude 9842.52 ft (3000 m) withoutfire resistance 1562 °F (850 °C) IEC 60695-2-1flame retardance V1 UL 94mechanical robustness Vibrations contactor open2 Gn, 5...300 HzVibrations contactor closed4 Gn, 5...300 HzShocks contactor open10 Gn for 11 msShocks contactor closed15 Gn for 11 msheight 3.03 in (77 mm)width 3.54 in (90 mm)depth 3.74 in (95 mm)net weight 2.26 lb(US) (1.027 kg)Ordering and shipping details Category 22354 - CTR,TESYS D,OPEN,9-38A ACDiscount Schedule I12GTIN 03389110541557Package weight(Lbs) 1.16 kg (2.56 lb(US))Returnability NoCountry of origin MXOffer Sustainability Sustainable offer status Green Premium productREACh Regulation REACh free of SVHC YesEU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.Contractual warranty Warranty 18 months -
View more
Documents
Language- All Languages15
- English14
- Chinese4
- French6
CatalogFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 7/12/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 7.0)DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesSize pdfSize 12.2 MBDate 5/15/19DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesControl Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Size pdfSize 15 MBDate 3/6/18DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Size pdfSize 108.2 MBDate 7/12/19DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Catalogue TeSys 2019 - Chapitre B8 - Contacteurs (Version 4.0)DescriptionPrésentation des gammes de contacteurs TeSys K, D. Gamme de mini contacteurs TeSys SK. Gamme de contacteurs modulaires Tesys GC, contateurs jour/nuit modulaires teSys GY, mini contacteurs modulaires TeSys SKGC, télérupteurs modulaires TeSys GF.Size pdfSize 12.3 MBDate 6/11/19DescriptionPrésentation des gammes de contacteurs TeSys K, D. Gamme de mini contacteurs TeSys SK. Gamme de contacteurs modulaires Tesys GC, contateurs jour/nuit modulaires teSys GY, mini contacteurs modulaires TeSys SKGC, télérupteurs modulaires TeSys GF.CADFormatSizeAdd to My DocumentsREVERSING CONTACTOR (Version 1.0)Files in documentSize zipSize 1.1 MBDate 12/18/17Files in documentCertificateFormatSizeAdd to My DocumentsInstruction SheetFormatSizeAdd to My DocumentsLC2 D.. 9 to 38 A reversing contactors with screw clamp terminals - Instruction sheet (Version 07)DescriptionRef on IS: W9 0381941 or W90381941Size pdfSize 850.6 KBDate 6/1/16DescriptionRef on IS: W9 0381941 or W90381941China RoHS declarationFormatSizeAdd to My DocumentsTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 12 V DC coilDescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 12 V DC coilSize pdfSize 195.3 KBDate 12/10/19DescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 12 V DC coilDeclaration of conformityFormatSizeAdd to My DocumentsSize pdfSize 303.8 KBDate 6/28/19End of Life InformationFormatSizeAdd to My DocumentsTeSys D Contactors AC 09 to 18A (Version 2.0)DescriptionTeSys D Contactors AC 09 to 18ASize pdfSize 157.9 KBDate 4/28/16DescriptionTeSys D Contactors AC 09 to 18AEU RoHS DeclarationFormatSizeAdd to My DocumentsTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 12 V DC coilDescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 12 V DC coilSize pdfSize 195.3 KBDate 12/10/19DescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 12 V DC coilProduct Environmental ProfileFormatSizeAdd to My Documents3P CONT 9A AC3 4KW 1NO 1NC 230VAC COIL (Version 3.0)Description3P CONT 9A AC3 4KW 1NO 1NC 230VAC COILSize pdfSize 132 KBDate 4/28/16Description3P CONT 9A AC3 4KW 1NO 1NC 230VAC COILREACh DeclarationFormatSizeAdd to My DocumentsTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 12 V DC coilDescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 12 V DC coilSize pdfSize 195.3 KBDate 12/10/19DescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 12 V DC coil -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.