Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Reversing contactordevice short name LC2Dcontactor application Motor controlResistive loadutilisation category AC-1AC-3device presentation Preassembled with reversing power busbarpoles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 HzPower circuit <= 300 V DC[Ie] rated operational current 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuitmotor power kW 18.5 kW 380...400 V AC 50 Hz11 kW 220...230 V AC 50 Hz22 kW 415...440 V AC 50 Hz22 kW 500 V AC 50 Hz30 kW 660...690 V AC 50 Hzmotor power HP (UL / CSA) 5 hp 230/240 V AC 60 Hz 1 phase10 hp 230/240 V AC 60 Hz 3 phase30 hp 575/600 V AC 60 Hz 3 phase10 hp 200/208 V AC 60 Hz 3 phase3 hp 115 V AC 60 Hz 1 phase30 hp 460/480 V AC 60 Hz 3 phasecontrol circuit type AC 50/60 Hz[Uc] control circuit voltage 440 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A 140 °F (60 °C) signalling circuit60 A 140 °F (60 °C) power circuitIrms rated making capacity 140 A AC signalling circuit IEC 60947-5-1250 A DC signalling circuit IEC 60947-5-1800 A 440 V power circuit IEC 60947rated breaking capacity 800 A 440 V power circuit IEC 60947[Icw] rated short-time withstand current 72 A 104 °F (40 °C) - 10 min power circuit165 A 104 °F (40 °C) - 1 min power circuit320 A 104 °F (40 °C) - 10 s power circuit720 A 104 °F (40 °C) - 1 s power circuit100 A - 1 s signalling circuit120 A - 500 ms signalling circuit140 A - 100 ms signalling circuitassociated fuse rating 10 A gG signalling circuit IEC 60947-5-180 A gG <= 690 V type 1 power circuit80 A gG <= 690 V type 2 power circuitaverage impedance 1.5 mOhm - Ith 60 A 50 Hz power circuit[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1Power circuit 600 V CSAPower circuit 600 V ULSignalling circuit 690 V IEC 60947-1Signalling circuit 600 V CSASignalling circuit 600 V ULelectrical durability 1.5 Mcycles 40 A AC-3 <= 440 V1.4 Mcycles 60 A AC-1 <= 440 Vpower dissipation per pole 2.4 W AC-35.4 W AC-1safety cover Withinterlocking type Mechanicalmounting support RailPlatestandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications GOSTCCCCSAULconnections - terminals Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable endControl circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable endControl circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable endControl circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable endControl circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable endControl circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable endPower circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)flexible without cable endPower circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)flexible without cable endPower circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)flexible with cable endPower circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)flexible with cable endPower circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)solid without cable endPower circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)solid without cable endtightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mmControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagonal 0.16 in (4 mm)Power circuit 44.25 lbf.in (5 N.m) EverLink BTR screw connectors 0.00…0.04 in² (1…25 mm²) hexagonal 0.16 in (4 mm)operating time 4...19 ms opening12...26 ms closingsafety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1mechanical durability 6 Mcyclesmaximum operating rate 3600 cyc/h 140 °F (60 °C)Complementary coil technology Without built-in suppressor modulecontrol circuit voltage limits Drop-out 0.3...0.6 Uc AC 50/60 Hz 140 °F (60 °C))Operational 0.8...1.1 Uc AC 50 Hz 140 °F (60 °C))Operational 0.85...1.1 Uc AC 60 Hz 140 °F (60 °C))inrush power in VA 140 VA 60 Hz 0.75 68 °F (20 °C))160 VA 50 Hz 0.75 68 °F (20 °C))hold-in power consumption in VA 13 VA 60 Hz 0.3 68 °F (20 °C))15 VA 50 Hz 0.3 68 °F (20 °C))heat dissipation 4…5 W 50/60 Hzauxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1Mirror contact 1 NC IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA signalling circuitminimum switching voltage 17 V signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm signalling circuitEnvironment IP degree of protection IP20 front face IEC 60529protective treatment TH IEC 60068-2-30pollution degree 3ambient air temperature for operation 23…140 °F (-5…60 °C)ambient air temperature for storage -76…176 °F (-60…80 °C)permissible ambient air temperature around the device -40…158 °F (-40…70 °C) at Ucoperating altitude 9842.52 ft (3000 m) withoutfire resistance 1562 °F (850 °C) IEC 60695-2-1flame retardance V1 UL 94mechanical robustness Vibrations contactor open2 Gn, 5...300 HzVibrations contactor closed4 Gn, 5...300 HzShocks contactor open10 Gn for 11 msShocks contactor closed15 Gn for 11 msheight 4.80 in (122 mm)width 4.69 in (119 mm)depth 4.72 in (120 mm)net weight 4.12 lb(US) (1.87 kg)Ordering and shipping details Category 22357 - CTR,TESYS D,OPEN,40-65A ACDiscount Schedule I12GTIN 03389118340848Package weight(Lbs) 2.10 kg (4.62 lb(US))Returnability NoCountry of origin FROffer Sustainability Sustainable offer status Green Premium productCalifornia proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.govREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.Contractual warranty Warranty 18 months -
View more
Documents
Language- All Languages14
- English13
- Chinese4
- French7
- German4
- Italian4
- Portuguese4
- Russian4
- Spanish4
CatalogFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 7/12/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 7.0)DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesSize pdfSize 12.2 MBDate 5/15/19DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesControl Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Size pdfSize 15 MBDate 3/6/18DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Size pdfSize 108.2 MBDate 7/12/19DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Catalogue TeSys 2019 - Chapitre B8 - Contacteurs (Version 4.0)DescriptionPrésentation des gammes de contacteurs TeSys K, D. Gamme de mini contacteurs TeSys SK. Gamme de contacteurs modulaires Tesys GC, contateurs jour/nuit modulaires teSys GY, mini contacteurs modulaires TeSys SKGC, télérupteurs modulaires TeSys GF.Size pdfSize 12.3 MBDate 6/11/19DescriptionPrésentation des gammes de contacteurs TeSys K, D. Gamme de mini contacteurs TeSys SK. Gamme de contacteurs modulaires Tesys GC, contateurs jour/nuit modulaires teSys GY, mini contacteurs modulaires TeSys SKGC, télérupteurs modulaires TeSys GF.CADFormatSizeAdd to My Documents3P EVLK REVERS CONT 40A (Version 1.0)Files in documentSize zipSize 1.2 MBDate 12/18/17Files in documentCertificateFormatSizeAdd to My DocumentsInstruction SheetFormatSizeAdd to My DocumentsLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 (Version 14)DescriptionLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 - Instruction SheetSize pdfSize 7.4 MBDate 9/1/17DescriptionLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 - Instruction SheetChina RoHS declarationFormatSizeAdd to My DocumentsLC2D40AR7_ROHS_CHINA_DECLARATIONDescriptionLC2D40AR7_ROHS_CHINA_DECLARATIONSize pdfSize 195.3 KBDate 12/7/19DescriptionLC2D40AR7_ROHS_CHINA_DECLARATIONDeclaration of conformityFormatSizeAdd to My DocumentsEnd of Life InformationFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsLC2D40AR7_ROHS_DECLARATIONDescriptionLC2D40AR7_ROHS_DECLARATIONSize pdfSize 195.3 KBDate 12/7/19DescriptionLC2D40AR7_ROHS_DECLARATIONProduct Environmental ProfileFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My DocumentsLC2D40AR7_REACH_DECLARATIONDescriptionLC2D40AR7_REACH_DECLARATIONSize pdfSize 195.3 KBDate 12/7/19DescriptionLC2D40AR7_REACH_DECLARATION -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.