View all
TeSys D Contactors

LC2D50A3ND
LC2D50A3ND
TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 60 V DC coil
Show more characteristics
LC2D50A3ND has not been replaced. Please contact your customer care center for more information.
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
-
Product availabilityNon-Stock - Not normally stocked in distribution facility
-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Reversing contactordevice short name LC2Dcontactor application Motor controlResistive loadutilisation category AC-1AC-3device presentation Preassembled with reversing power busbarpoles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 HzPower circuit <= 300 V DC[Ie] rated operational current 50 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit80 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuitmotor power kW 15 kW 220...230 V AC 50 Hz22 kW 380...400 V AC 50 Hz30 kW 500 V AC 50 Hz33 kW 660...690 V AC 50 Hz25 kW 415 V AC 50 Hz30 kW 440 V AC 50 Hzmotor power HP (UL / CSA) 3 hp 115 V AC 60 Hz 1 phase7.5 hp 230/240 V AC 60 Hz 1 phase15 hp 200/208 V AC 60 Hz 3 phase15 hp 230/240 V AC 60 Hz 3 phase40 hp 460/480 V AC 60 Hz 3 phase40 hp 575/600 V AC 60 Hz 3 phasecontrol circuit type DC standard[Uc] control circuit voltage 60 V DCauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A 140 °F (60 °C) signalling circuit80 A 140 °F (60 °C) power circuitIrms rated making capacity 140 A AC signalling circuit IEC 60947-5-1250 A DC signalling circuit IEC 60947-5-1900 A 440 V power circuit IEC 60947rated breaking capacity 900 A 440 V power circuit IEC 60947[Icw] rated short-time withstand current 400 A 104 °F (40 °C) - 10 s power circuit810 A 104 °F (40 °C) - 1 s power circuit84 A 104 °F (40 °C) - 10 min power circuit208 A 104 °F (40 °C) - 1 min power circuit100 A - 1 s signalling circuit120 A - 500 ms signalling circuit140 A - 100 ms signalling circuitassociated fuse rating 10 A gG signalling circuit IEC 60947-5-1100 A gG <= 690 V type 1 power circuit100 A gG <= 690 V type 2 power circuitaverage impedance 1.5 mOhm - Ith 80 A 50 Hz power circuit[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1Power circuit 600 V CSAPower circuit 600 V ULSignalling circuit 690 V IEC 60947-1Signalling circuit 600 V CSASignalling circuit 600 V ULelectrical durability 1.45 Mcycles 50 A AC-3 <= 440 V0.5 Mcycles 80 A AC-1 <= 440 Vpower dissipation per pole 3.7 W AC-39.6 W AC-1safety cover Withinterlocking type Mechanicalmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications CSAGOSTCCCULconnections - terminals Control circuit spring terminals 1 0.00 in² (2.5 mm²)flexible without cable endControl circuit spring terminals 2 0.00 in² (2.5 mm²)flexible without cable endPower circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)flexible without cable endPower circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)flexible without cable endPower circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)flexible with cable endPower circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)flexible with cable endPower circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)solid without cable endPower circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)solid without cable endtightening torque Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagonal 0.16 in (4 mm)Power circuit 44.25 lbf.in (5 N.m) EverLink BTR screw connectors 0.00…0.04 in² (2.5…25 mm²) hexagonal 0.16 in (4 mm)operating time 16...24 ms opening42.5...57.5 ms closingsafety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1mechanical durability 10 Mcyclesmaximum operating rate 3600 cyc/h 140 °F (60 °C)Complementary coil technology Built-in bidirectional peak limiting diode suppressorcontrol circuit voltage limits Drop-out 0.1...0.3 Uc DC 140 °F (60 °C))Operational 0.75...1.25 Uc DC 140 °F (60 °C))time constant 34 msinrush power in W 19 W 68 °F (20 °C))hold-in power consumption in W 7.4 W 68 °F (20 °C)auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1Mirror contact 1 NC IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA signalling circuitminimum switching voltage 17 V signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm signalling circuitEnvironment IP degree of protection IP20 front face IEC 60529protective treatment TH IEC 60068-2-30pollution degree 3ambient air temperature for operation 23…140 °F (-5…60 °C)ambient air temperature for storage -76…176 °F (-60…80 °C)permissible ambient air temperature around the device -40…158 °F (-40…70 °C) at Ucoperating altitude 9842.52 ft (3000 m) withoutfire resistance 1562 °F (850 °C) IEC 60695-2-1flame retardance V1 UL 94mechanical robustness Vibrations contactor open2 Gn, 5...300 HzVibrations contactor closed4 Gn, 5...300 HzShocks contactor open10 Gn for 11 msShocks contactor closed15 Gn for 11 msheight 4.80 in (122 mm)width 4.69 in (119 mm)depth 4.72 in (120 mm)net weight 4.48 lb(US) (2.03 kg)Ordering and shipping details Category 22358 - CTR,TESYS D,OPEN,40-65A DCDiscount Schedule I12GTIN 03389118340251Package weight(Lbs) 2.10 kg (4.62 lb(US))Returnability NoCountry of origin FRContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages7
- English6
- Chinese3
- French5
- German3
- Italian3
- Portuguese3
- Russian3
- Spanish3
CatalogFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 7/12/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 7.0)DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesSize pdfSize 12.2 MBDate 5/15/19DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesControl Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Size pdfSize 15 MBDate 3/6/18DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Size pdfSize 108.2 MBDate 7/12/19DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Catalogue TeSys 2019 - Chapitre B8 - Contacteurs (Version 4.0)DescriptionPrésentation des gammes de contacteurs TeSys K, D. Gamme de mini contacteurs TeSys SK. Gamme de contacteurs modulaires Tesys GC, contateurs jour/nuit modulaires teSys GY, mini contacteurs modulaires TeSys SKGC, télérupteurs modulaires TeSys GF.Size pdfSize 12.3 MBDate 6/11/19DescriptionPrésentation des gammes de contacteurs TeSys K, D. Gamme de mini contacteurs TeSys SK. Gamme de contacteurs modulaires Tesys GC, contateurs jour/nuit modulaires teSys GY, mini contacteurs modulaires TeSys SKGC, télérupteurs modulaires TeSys GF.CADFormatSizeAdd to My Documents3P EVLK REVERS CONT 40A (Version 1.0)Files in documentSize zipSize 1.2 MBDate 12/18/17Files in documentInstruction SheetFormatSizeAdd to My DocumentsLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 (Version 14)DescriptionLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 - Instruction SheetSize pdfSize 7.4 MBDate 9/1/17DescriptionLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 - Instruction Sheet -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.