  • Main
    range
    TeSys
    product name
    TeSys Integral 63
    product or component type
    Contactor breaker
    device short name
    LD1LD
    Complementary
    utilisation category
    AC-43
    poles description
    3P
    [Ue] rated operational voltage
    690 V AC 50/60 Hz
    [Ie] rated operational current
    63 A AC AC-43
    [Ith] conventional free air thermal current
    63 A 104 °F (40 °C)
    motor power kW
    15 kW 220...240 V AC 50/60 Hz
    30 kW 400 V AC 50/60 Hz
    33 kW 415 V AC 50/60 Hz
    37 kW 500 V AC 50/60 Hz
    55 kW 660 V AC 50/60 Hz
    33 kW 440 V AC 50/60 Hz
    [Uc] control circuit voltage
    120 V AC 60 Hz
    control type
    Knob black front
    Irms rated making capacity
    756 A IEC 60947-4
    946 A IEC 60947-4
    [Ipk] rated peak withstand current
    105 kA IEC 60947-2
    breaking capacity
    Icu 10 kA 600...690 V 0.5) IEC 60947-2
    Icu 30 kA 480...525 V 0.25) IEC 60947-6-2
    Icu 50 kA <= 440 V 0.25) IEC 60947-2
    [Ics] rated service breaking capacity
    10 kA 600...690 V IEC 60947-2
    35 kA 480...525 V IEC 60947-2
    50 kA <= 440 V IEC 60947-2
    maximum breaking time
    4 ms
    thermal stress limit
    300000 A².s
    [Uimp] rated impulse withstand voltage
    8 kV IEC 60947-4
    control circuit voltage limits
    0.25...0.7 Uc drop-out 131 °F (55 °C)
    0.85...1.1 Uc operation 131 °F (55 °C)
    [Ui] rated insulation voltage
    690 V IEC 60947-1
    inrush power in VA
    450 VA 60 Hz 68 °F (20 °C))
    hold-in power consumption in VA
    25 VA 68 °F (20 °C))
    heat dissipation
    5 W 32 A per pole, hot state power circuit
    7 W 50 A per pole, hot state power circuit
    9 W 63 A per pole, hot state power circuit
    4.4 W 25 A per pole, hot state power circuit
    5.8 W 40 A per pole, hot state power circuit
    11 W at 60 Hz control circuit
    operating time
    12...35 ms AC closing 68 °F (20 °C) control circuit
    7...20 ms AC opening 68 °F (20 °C) control circuit
    electrical durability
    1 Mcycles AC-3 3 kA 415 V - after 1 cycle O-CO-r-CO at Isc
    0.9 Mcycles AC-3 10 kA 415 V - after 1 cycle O-CO-r-CO at Isc
    0.6 Mcycles AC-3 25 kA 415 V - after 1 cycle O-CO-r-CO at Isc
    0.5 Mcycles AC-3 35 kA 415 V - after 1 cycle O-CO-r-CO at Isc
    0.2 Mcycles AC-3 50 kA 415 V - after 1 cycle O-CO-r-CO at Isc
    mechanical durability
    1.2 Mcycles
    connections - terminals
    Power circuit screw clamp terminals 1 0.01…0.08 in² (6…50 mm²) flexible - without cable end
    Power circuit screw clamp terminals 2 0.01…0.04 in² (6…25 mm²) flexible - without cable end
    Power circuit screw clamp terminals 1 0.01…0.04 in² (6…25 mm²) flexible - with cable end
    Power circuit screw clamp terminals 2 0.01…0.04 in² (6…25 mm²) flexible - with cable end
    Power circuit screw clamp terminals 1 0.01…0.08 in² (6…50 mm²) solid
    tightening torque
    Power circuit 53.10 lbf.in (6 N.m) screw clamp terminals
    width
    3.54 in (90 mm)
    height
    9.57 in (243 mm)
    depth
    7.56 in (192 mm)
    net weight
    8.16 lb(US) (3.7 kg)
    Environment
    standards
    VDE 0171
    VDE 0113
    VDE 0110
    NEN
    IEC 60364
    IEC 60947-2
    IEC 60204-2
    BS 4752
    BS 4941
    NF C 79-100
    NBN
    NF C 63-130
    NF C 63-650
    IEC 60158-1
    NF C 63-110
    NF C 63-120
    IEC 60947-4
    VDE 0660
    BS 5424
    VDE 0100
    VDE 471
    IEC 60204-1
    NF C 20-040
    IEC 60947-1
    VDE 0170
    product certifications
    BV
    DEMKO
    ASEFA
    SETI
    SCC
    ASE
    USSR
    NKK
    UL
    NEMKO
    OVE
    GL
    ASTA
    CSA
    DNV
    RINA
    LROS (Lloyds register of shipping)
    protective treatment
    TH
    ambient air temperature for operation
    -4…140 °F (-20…60 °C)
    ambient air temperature for storage
    -40…176 °F (-40…80 °C)
    mechanical robustness
    Vibrations de-energised3 Gn, 1...300 Hz
    Vibrations energised3 Gn, 1...300 Hz
    Shocks de-energised8 Gn for 11 ms
    Shocks energised8 Gn for 11 ms
    IP degree of protection
    IP20 B IEC 60144
    IP20 B IEC 60529
    operating altitude
    9842.52 ft (3000 m) without derating
    Ordering and shipping details
    Category
    22382-STRS,INTEGRAL 32&63,OPEN
    Discount Schedule
    I11
    GTIN
    00785901225928
    Package weight(Lbs)
    9.03 lb(US) (4.098 kg)
    Returnability
    No
    Country of origin
    FR
    Offer Sustainability
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information.
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages8
    • English8
    • French5
    • German4
    • Italian4
    • Portuguese4
    • Spanish4
    Catalog
    Format
    Size
    Date
    Add to My Documents
    TeSys catalogue - 2019 - 2020 - chapter A5 - All in one motor starters - Integral 63 (Version 5.0)
    Description
    TeSys - chapter A5 - All in one motor starters - Integral 63
    Size pdf
    Size 3.6 MB
    Date 5/15/19
    Description
    TeSys - chapter A5 - All in one motor starters - Integral 63
    Catalogue TeSys - 2019 - Chapitre A5 - Démarreurs tout-en-un Integral 63 (Version 3.0)
    Description
    Présentation des démarreurs-moteurs tout en un Intégral 63 : contacteurs/disjoncteurs, contacteurs/disjoncteurs/inverseurs, sans ou avec module de protection réglable.
    Size pdf
    Size 3.8 MB
    Date 6/11/19
    Description
    Présentation des démarreurs-moteurs tout en un Intégral 63 : contacteurs/disjoncteurs, contacteurs/disjoncteurs/inverseurs, sans ou avec module de protection réglable.
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD file (on TraceParts) for LD1LD030FC: TeSys Integral - contactor breaker - 63 A AC-43 - 120 V AC coil (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for LD1LD030FC: TeSys Integral - contactor breaker - 63 A AC-43 - 120 V AC coil (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    Size zip
    Size 362 KB
    Date 9/24/18
    Files in document
    Instruction Sheet
    Format
    Size
    Date
    Add to My Documents
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    LD1LD030FC : LD1LD030FC_ROHS_CHINA_DECLARATION
    Description
    LD1LD030FC_ROHS_CHINA_DECLARATION
    Size pdf
    Size 195.3 KB
    Date 12/13/19
    Description
    LD1LD030FC_ROHS_CHINA_DECLARATION
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    LD1LD030FC : LD1LD030FC_ROHS_DECLARATION
    Description
    LD1LD030FC_ROHS_DECLARATION
    Size pdf
    Size 195.3 KB
    Date 12/13/19
    Description
    LD1LD030FC_ROHS_DECLARATION
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    LD1LD030FC : LD1LD030FC_REACH_DECLARATION
    Description
    LD1LD030FC_REACH_DECLARATION
    Size pdf
    Size 195.3 KB
    Date 12/13/19
    Description
    LD1LD030FC_REACH_DECLARATION
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.