TeSys LRF - electronic thermal overload relay - 90...150 A - class 10
Show more characteristics
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
-
Product availabilityStock - Normally stocked in distribution facility
-
Characteristics
Main range TeSysproduct name TeSys LRFdevice short name LR9Fproduct or component type Electronic thermal overload relayrelay application Motor protectionproduct compatibility LC1F115...LC1F185network type ACthermal overload class Class 10 IEC 60947-4thermal protection adjustment range 90…150 AComplementary network frequency 50/60 Hzsupply voltage limits 17…32 Vmounting support Direct on contactorPlatetripping threshold 1.12 +/- 0.06 In tripping IEC 60947-4-1surge withstand 4 kV IEC 61000-4-5contacts type and composition 1 NO + 1 NC[Ith] conventional free air thermal current 5 A control circuit[Ue] rated operational voltage 1000 V AC 50/60 Hz power circuit VDE 0110 group C[Ui] rated insulation voltage Power circuit 1000 V AC IEC 60947-4[Uimp] rated impulse withstand voltage 8 kV IEC 60947-1phase failure sensitivity Tripping in 4 s +/- 20 % IEC 60947-4-1reset Manual reset on front relaycontrol type Dial white full-load current adjustmentTest button redPush-button red resetPush-button stoplocal signalling Trip indicatortemperature compensation -4…158 °F (-20…70 °C)current consumption <= 5 mA no-loadswitching capacity for alarm 0...150 mAmaximum voltage drop <2.5 V closed stateconnections - terminals Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…2.5 mm²) flexible - with cable endControl circuit screw clamp terminals 1 0.00…0.00 in² (0.75…2.5 mm²) solidControl circuit screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²) flexible - without cable endControl circuit screw clamp terminals 2 0.00…0.00 in² (1…1.5 mm²) flexible - with cable endControl circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible - without cable endControl circuit screw clamp terminals 2 0.00 in² (1 mm²) solidPower circuit lugs-ring terminals M8tightening torque Control circuit 1.2 N.m screw clamp terminalsPower circuit 18 N.m screw clamp terminalsheight 3.78 in (96 mm)width 4.53 in (115 mm)depth 4.86 in (123.5 mm)net weight 1.95 lb(US) (0.885 kg)Environment standards VDE 0660IEC 60255-17IEC 60947-4-1IEC 60255-8EN 60947-4-1product certifications ULCSAprotective treatment THIP degree of protection IP20 IEC 60529IP20 VDE 0106ambient air temperature for operation -4…131 °F (-20…55 °C) IEC 60255-8ambient air temperature for storage -40…185 °F (-40…85 °C)operating altitude <= 6561.68 ft (2000 m) without deratingfire resistance 1562 °F (850 °C) IEC 60695-2-1mechanical robustness Shocks13 Gn for 11 ms IEC 60068-2-7Vibrations 5...300 Hz2 Gn IEC 60068-2-6dielectric strength 6 kV 50 Hz IEC 255-5electromagnetic compatibility Resistance to electrostatic discharge 6 kV in indirect mode IEC 61000-4-2Resistance to electrostatic discharge 8 kV in air IEC 61000-4-2Radiated radio-frequency electromagnetic field immunity test 10 V/m IEC 61000-4-3Fast transients immunity test 2 kV IEC 61000-4-4Ordering and shipping details Category 22334 - CONTACTOR,F-LINE,OVERLOADSDiscount Schedule I12GTIN 00785901566007Package weight(Lbs) 0.87 kg (1.92 lb(US))Returnability YesCountry of origin FROffer Sustainability Sustainable offer status Green Premium productCalifornia proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.govREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information.Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.Contractual warranty Warranty 18 months -
View more
Documents
Language- All Languages13
- English14
- French7
- German7
- Russian7
- Spanish7
CatalogFormatSizeAdd to My DocumentsDigest 178 Catalog 18: Contactors and Starters-IEC (Version 1.0)DescriptionSection 18 of Digest 178 provides selection and ordering information for IEC contactors and starters - TeSys K, TeSys D, TeSys F, TeSys U, TeSys GV, and TeSys LS1. Replaces Digest 177 section 18; 0100CT1501_SEC-18Size pdfSize 6.8 MBDate 9/13/19DescriptionSection 18 of Digest 178 provides selection and ordering information for IEC contactors and starters - TeSys K, TeSys D, TeSys F, TeSys U, TeSys GV, and TeSys LS1. Replaces Digest 177 section 18; 0100CT1501_SEC-18Control Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Size pdfSize 15 MBDate 3/6/18DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Data BulletinFormatSizeAdd to My DocumentsMotor Control Solutions for the North American Market (Version 2.0)DescriptionThis bulletin contains information regarding the application of solutions to meet your motor control and protection needs in the US and Canada.Size pdfSize 1.5 MBDate 2/10/17DescriptionThis bulletin contains information regarding the application of solutions to meet your motor control and protection needs in the US and Canada.CADFormatSizeAdd to My DocumentsIEC Overload Relay, 30-150A, 3 Pole, F-Line (Version 1.2)Files in documentSize zipSize 429.3 KBDate 11/13/02Files in documentTeSys F Compensated and differential overload relays Class 10 for mounting on contactor or independent mounting (Version 1.0)Files in documentSize zipSize 945.8 KBDate 4/2/14Files in documentSize zipSize 329.8 KBDate 1/13/05Instruction SheetFormatSizeAdd to My DocumentsSize pdfSize 2.7 MBDate 5/1/15China RoHS declarationFormatSizeAdd to My DocumentsLR9F5369 : LR9F5369_ROHS_CHINA_DECLARATIONDescriptionLR9F5369_ROHS_CHINA_DECLARATIONSize pdfSize 195.3 KBDate 12/14/19DescriptionLR9F5369_ROHS_CHINA_DECLARATIONEU RoHS DeclarationFormatSizeAdd to My DocumentsLR9F5369 : LR9F5369_ROHS_DECLARATIONDescriptionLR9F5369_ROHS_DECLARATIONSize pdfSize 195.3 KBDate 12/14/19DescriptionLR9F5369_ROHS_DECLARATIONREACh DeclarationFormatSizeAdd to My DocumentsLR9F5369 : LR9F5369_REACH_DECLARATIONDescriptionLR9F5369_REACH_DECLARATIONSize pdfSize 195.3 KBDate 12/14/19DescriptionLR9F5369_REACH_DECLARATION -