View all
TeSys T Motor Management System

LTMR08EBD
LTMR08EBD
motor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IP
Show more characteristics
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
-
Product availabilityStock - Normally stocked in distribution facility
-
Characteristics
Main range TeSysproduct name TeSys Tdevice short name LTMRproduct or component type Motor controllerdevice application Equipment monitoring and controlmeasurement current 0.4…8 A[Us] rated supply voltage 24 V DCcurrent consumption 56...127 mAsupply voltage limits 20.4…26.24 V DCcommunication port protocol Modbus TCP/EtherNet/IPbus type Ethernet IEEE 802.3 0...159 10...100 Mbit/s, RJ45 2 shielded twisted pairsComplementary [Ui] rated insulation voltage 690 V EN/IEC 60947-1690 V CSA C22.2 No 14690 V UL 508[Uimp] rated impulse withstand voltage 6 kV current or voltage measurement circuit EN/IEC 60947-4-10.8 kV communication circuit EN/IEC 60947-4-10.8 kV supply, inputs and outputs EN/IEC 60947-4-1short-circuit withstand 100 kA EN/IEC 60947-4-1associated fuse rating 4 A gG output0.5 A gG control circuitprotection type Phase failureLocked rotorEarth-leakage protectionThermal protectionOverloadPhase unbalanceReverse polarity protectionPower factor variationOverload (long time)Thermal overload protectionLoad fluctuationnetwork and machine diagnosis type Event recordingRemaining operating time before overload trippingTrip context informationWaiting time after overload trippingRunning hours counter/operating timeTrip history informationFault recordingStarting current and timePhase fault and earth fault trip countersMotor control command recordinglogic input number 6input current 7 mAcurrent state 0 guaranteed Logic input < 5 V <= 15 mA 5 mscurrent state 1 guaranteed Logic input < 15 V 2...15 mA 15 msmaximum output switching frequency 2 Hzload current 5 A 250 V AC logic output5 A 30 V DC logic outputpermissible power 480 VA AC-15), Ie = 2 A, 500000 cycles output)30 W DC-13), Ie = 1.25 A, 500000 cycles output)maximum operating rate 1800 cyc/hcontacts type and composition 1 NO + 1 NC fault signal3 NOmetering type Average current IavgTemperatureEarth-fault currentPhase current I1, I2, I3 RMSImbalance currentmeasurement accuracy 5...15 % earth fault current internal measurement for current > 0.1 A)1 % voltage 100...830 V)3 % power factor cos φ > 0.6)5 % earth fault current external measurement < 5 % or 0.01 A)+/- 30 min/year internal clock0,02 temperature1 % current5 % active and reactive powerovervoltage category IIIconnection pitch 0.20 in (5.08 mm)connections - terminals Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable endControl circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable endControl circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable endControl circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable endControl circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable endControl circuit connector 2 0.00…0.00 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable endControl circuit connector 2 0.00…0.00 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable endControl circuit connector 2 0.00…0.00 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable endtightening torque Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)pollution degree 3electromagnetic compatibility Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2)Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3)Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4)Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4)Voltage dips and interruptions immunity test 70 %, 500 ms)EN/IEC 61000-4-11)Conducted RF disturbances 10 V)EN/IEC 61000-4-6)Surges 0.5 kV)EN/IEC 61000-4-5)Surges 1 kV)EN/IEC 61000-4-5)Surges 1 kV)EN/IEC 61000-4-5)Surges 1 kV)EN/IEC 61000-4-5)Surges 2 kV)EN/IEC 61000-4-5)Surges 2 kV)EN/IEC 61000-4-5)Surges 4 kV)EN/IEC 61000-4-5)width 3.58 in (91 mm)height 2.40 in (61 mm)depth 4.82 in (122.5 mm)net weight 1.17 lb(US) (0.53 kg)web services Web servercompatibility code LTMREnvironment standards IACS E10UL 508CSA C22.2 No 14EN 60947-4-1IEC 60947-4-1product certifications CCCABSC-TickNOMCSARMRoSRINAULBVKERIDNVGLEACLROS (Lloyds register of shipping)ATEXprotective treatment 12 x 24 hour cycles EN/IEC 60068-2-3048 h EN/IEC 60070-2-11TH EN/IEC 60068fire resistance 1202 °F (650 °C) EN/IEC 60695-2-121760 °F (960 °C) UL 94ambient air temperature for operation -4…140 °F (-20…60 °C)ambient air temperature for storage -40…176 °F (-40…80 °C)operating altitude <= 6561.68 ft (2000 m) without deratingmechanical robustness Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27IP degree of protection IP20Ordering and shipping details Category 22338 - SOLID STATE OVERLOAD RELAYSDiscount Schedule I12GTIN 00785901552598Package weight(Lbs) 0.56 kg (1.24 lb(US))Returnability YesCountry of origin CNOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information.Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.Contractual warranty Warranty 18 months -
View more
Documents
Language- All Languages32
- English24
- Chinese6
- French16
- German6
- Italian6
- Portuguese6
- Russian6
- Spanish9
CatalogFormatSizeAdd to My DocumentsDigest 178 Catalog 16: NEMA and Definite Purpose Contactors and Starters (Version 1.0)DescriptionSection 16 of Digest 178 Catalog includes selection and ordering information for NEMA and definite purpose contactors and starters. Replaces Digest 177 section 16; 0100CT1501_SEC-16Size pdfSize 6.5 MBDate 9/25/19DescriptionSection 16 of Digest 178 Catalog includes selection and ordering information for NEMA and definite purpose contactors and starters. Replaces Digest 177 section 16; 0100CT1501_SEC-16Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 7/12/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter B12 Motor management systems TeSys LUTM, T (Version 6.0)DescriptionMotor overload protection, alarms, communication functions : TeSys LUTMMotor overload protection, alarm, measurement functions : TeSys TSize pdfSize 3.4 MBDate 5/15/19DescriptionMotor overload protection, alarms, communication functions : TeSys LUTMMotor overload protection, alarm, measurement functions : TeSys TCatalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Size pdfSize 108.2 MBDate 7/12/19DescriptionLe catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.Catalogue TeSys 2019 - Chapitre B12 - Controleurs de moteurs (Version 4.0)DescriptionPrésentation des contrôleurs pour la surveillance des moteurs: surveillance dintensité, de tension, avec génération dalarme, communication sur bus selon modèleSize pdfSize 4.4 MBDate 6/11/19DescriptionPrésentation des contrôleurs pour la surveillance des moteurs: surveillance dintensité, de tension, avec génération dalarme, communication sur bus selon modèleUser guideFormatSizeAdd to My DocumentsTeSys Programmer Firmware Update Utility for LTMR & LTMCU (Version 1.0)DescriptionThis User Manual describes how to upgrade / downgrade TeSys T product range (LTMR and LTMCU) firmware using the TeSys Programmer v2.1.0.0Size pdfSize 1.8 MBDate 11/30/18DescriptionThis User Manual describes how to upgrade / downgrade TeSys T product range (LTMR and LTMCU) firmware using the TeSys Programmer v2.1.0.0Size pdfSize 2.3 MBDate 7/1/18Size pdfSize 21.7 MBDate 9/1/14TeSys DFB Offer for V2 Unity Pro - User manual (Version 1.0)DescriptionTeSys DFB Offer for V2 Unity Pro - User manualSize pdfSize 991.2 KBDate 9/15/09DescriptionTeSys DFB Offer for V2 Unity Pro - User manualSize pdfSize 23.6 MBDate 8/1/13Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation (Version 1.1)DescriptionOffre TeSys DFB V2 pour Unity Pro - Manuel d'utilisationSize pdfSize 1 MBDate 10/7/09DescriptionOffre TeSys DFB V2 pour Unity Pro - Manuel d'utilisationTeSys T DTM para el contenedor de FDT & Editor de lógica personalizada - Ayuda en línea (Version 01)Size pdfSize 21.9 MBDate 8/1/13Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation (Version 1.0)DescriptionOffre TeSys DFB V2 pour Unity Pro - Manuel d'utilisationSize pdfSize 1,021.1 KBDate 9/15/09DescriptionOffre TeSys DFB V2 pour Unity Pro - Manuel d'utilisationData BulletinFormatSizeAdd to My DocumentsMotor Control Solutions for the North American Market (Version 2.0)DescriptionThis bulletin contains information regarding the application of solutions to meet your motor control and protection needs in the US and Canada.Size pdfSize 1.5 MBDate 2/10/17DescriptionThis bulletin contains information regarding the application of solutions to meet your motor control and protection needs in the US and Canada.CADFormatSizeAdd to My DocumentsCAD file (on TraceParts) for LTMR08EBD: motor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IP (Version 2.0)Size pdfSize 230.1 KBDate 4/11/19Size zipSize 1.4 MBDate 4/24/18Files in documentSize dwgSize 755.1 KBDate 4/24/18Motor management system TeSys T, Ethernet motor management, Ethernet relay (Version 1.0)Files in documentSize zipSize 862.5 KBDate 4/2/14Files in documentCertificateFormatSizeAdd to My DocumentsSize pdfSize 205 KBDate 11/12/14Size pdfSize 1.9 MBDate 12/4/09Instruction SheetFormatSizeAdd to My DocumentsSize pdfSize 4.2 MBDate 7/31/18China RoHS declarationFormatSizeAdd to My Documentsmotor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IPDescriptionmotor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IPSize pdfSize 195.3 KBDate 12/7/19Descriptionmotor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IPDeclaration of conformityFormatSizeAdd to My DocumentsEnd of Life InformationFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My Documentsmotor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IPDescriptionmotor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IPSize pdfSize 195.3 KBDate 12/7/19Descriptionmotor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IPProduct Environmental ProfileFormatSizeAdd to My DocumentsMotor management system (Version 2.0)DescriptionNoneSize pdfSize 287.1 KBDate 3/31/16DescriptionNoneREACh DeclarationFormatSizeAdd to My Documentsmotor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IPDescriptionmotor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IPSize pdfSize 195.3 KBDate 12/7/19Descriptionmotor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IP -
View more
Software and Firmware
Language- English1
EDS FilesFormatSizeAdd to My DocumentsEDS file for TeSys T EIP (Version 1.0)DescriptionDetails of data exchanged by TeSys T EIP. Zip fileSize zipSize 104.7 KBDate 6/5/15DescriptionDetails of data exchanged by TeSys T EIP. Zip file -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.