View all
PowerLogic EM3500 series

METSEEM3561A

METSEEM3561A

PowerLogic EM3500 DIN rail meter - BACnet without logging - flexible transducer
Show more characteristics
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
-
Product availabilityNon-Stock - Not normally stocked in distribution facility
-
Characteristics
Main range PowerLogicrange of product PowerLogic EM3500device short name EM3561Aproduct or component type Energy metermetering type Current I1, I2, I3, IavgPeak demand power PM, QM, SMDemand power P, Q, SVoltage U21, U32, U13, V1, V2, V3Complementary poles description 3P + Ntype of measurement Active and reactive power totalActive and reactive power per phaseApparent power totalApparent power per phasePower factor totalPower factor per phasePeak demand powerCurrentVoltageFrequencydevice application Sub billingPartial meteraccuracy class Class 0.5S power IEC 62053-22Class 0.5S energy IEC 62053-22Class 0.5S power ANSI C12.20Class 0.5S energy ANSI C12.20measurement accuracy Power +/- 0.5 %Energy +/- 0.5 %input type Rogowski coil 50...5000 Arated voltage 90…347 Vnetwork frequency 60 Hz50 Hztechnology type Electronicdisplay type Backlit LCDmeasurement current 20…5000 Adisplay digits 5information displayed Status and alertCommunication with systemInput/output statusErrorTx activityRx activityInstant power per usagetamperproof of settings Protected by access codecommunication port protocol BACnet MS/TP 9600 bauds...115200 bauds (automatic detection) - 2-wirecommunication port support Screw terminal block RS485communication service Total cumulated energyTotal cumulated active energydata recording Energy consumption logsDemand intervals Fixed or rolling blockExternal synchronisation to communicationlocal signalling Red LED threshold reachedGreen flashing LED output signalnumber of accumulator inputs 2 pulse[Ue] rated operational voltage 90...347 V AC 50/60 Hz between phase and neutral UL156...600 V AC 50/60 Hz between phases UL90...300 V AC 50/60 Hz between phase and neutral CE125...300 V DCpower consumption in VA 5 VA 347 V AC between phase and neutral)5 VA 600 V AC between phases)power consumption in W 3 W 300 Vride-through time 100 ms 120 V ACmounting mode By screwsClip-onmounting support DIN railstandards CSA C22.2 No 14-05IEC 61010-1UL 508product certifications CE IEC 61010CULus UL 508Environment relative humidity 0…95 %ambient air temperature for operation -22…158 °F (-30…70 °C)ambient air temperature for storage -40…185 °F (-40…85 °C)color Dark grey9 mm pitches 12width 4.21 in (107 mm)height 3.58 in (91 mm)depth 2.32 in (59 mm)Ordering and shipping details Category 09798 - POWERLOGIC EM3500 SERIESDiscount Schedule PL1Package weight(Lbs) 0.54 kg (1.2 lb(US))Returnability YesOffer Sustainability California proposition 65 WARNING: This product can expose you to chemicals which are known to the State of California to cause Carcinogen and Reproductive harm.For more information go to www.p65warnings.ca.govEU RoHS Directive Not compliantChina RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information.WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. -
View more
Documents
Language- English3
China RoHS declarationFormatSizeAdd to My DocumentsPowerLogic EM3500 DIN rail meter - BACnet without logging - flexible transducerDescriptionPowerLogic EM3500 DIN rail meter - BACnet without logging - flexible transducerSize pdfSize 195.3 KBDate 12/6/19DescriptionPowerLogic EM3500 DIN rail meter - BACnet without logging - flexible transducerEU RoHS DeclarationFormatSizeAdd to My DocumentsPowerLogic EM3500 DIN rail meter - BACnet without logging - flexible transducerDescriptionPowerLogic EM3500 DIN rail meter - BACnet without logging - flexible transducerSize pdfSize 195.3 KBDate 12/6/19DescriptionPowerLogic EM3500 DIN rail meter - BACnet without logging - flexible transducerTechnical leafletFormatSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.