Schneider Electric USA Website

Welcome to our website.

Select your location

View all PowerLogic EM4200 Series Enercept
Schneider Eletric METSEEM4236 Picture

METSEEM4236

Schneider Eletric METSEEM4236 Picture
METSEEM4236

Enercept Meter, class 0.2S, Modbus/BACnet RS-485, user choice, ANSI wire code

Show more characteristics
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
  • 576.00 USD
    Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
The maximum number of products that can be compared is 4

  • Main
    range
    PowerLogic
    product name
    PowerLogic EM4200
    device short name
    Enercept
    product or component type
    Energy meter
    type of cable
    ANSI cable
    device application
    Power monitoring
    Complementary
    metering type
    Active, reactive, apparent energy (signed, four quadrant)
    Apparent power S, S1, S2, S3
    Demand power P, Q, S
    Active power P, P1, P2, P3
    Reactive power Q, Q1, Q2, Q3
    Power factor
    Average current Iavg
    Peak demand power PM, QM, SM
    Frequency
    Voltage U21, U32, U13, V1, V2, V3
    measurement current
    50…5000 A
    measurement voltage
    90 V AC 45...65 Hz minimum per phase
    480 V AC 45...65 Hz between phases
    300 V AC 45...65 Hz between phase and neutral
    frequency measurement range
    45…65 Hz
    network frequency
    50 Hz
    60 Hz
    display type
    Without display
    control type
    ADDRESS 1…99 rotary
    CT AMPS 5…5000 rotary
    local signalling
    Status LED green and red)
    Line fault 3 LED green, orange and red)
    Dial pointer indication LED yellow)
    RX/TX 2 LED green, orange and red)
    Signal
    current 0.333 V 33 kOhm)
    voltage single phase 2.5 MOhm)
    voltage phase to phase 5 MOhm)
    number of inputs
    0
    number of outputs
    0
    communication port protocol
    Modbus RTU 9600 bauds...115200 bauds (automatic detection)
    BACnet MS/TP 9600 bauds...115200 bauds (automatic detection)
    communication of data
    Remote control orders
    Total energy
    Net energy
    Demand intervals
    External synchronisation to communication
    Fixed or rolling block
    connections - terminals
    Input/output plug-in connector bottom) 0.00…0.00 in² (0.2…1.5 mm²)
    Current transformer plug-in connector bottom) 0.00…0.00 in² (0.2…1.5 mm²)
    Communication plug-in connector bottom) 0.00…0.00 in² (0.2…1.5 mm²)
    wire stripping length
    0.24 in (6 mm)
    mounting mode
    By screws
    Clip-on
    By hook
    mounting support
    Enclosure
    DIN rail
    standards
    EN 61010-1
    UL 61010-1
    product certifications
    CE EN 61010-1
    CULus UL 61010-1
    BTL
    ANSI
    width
    1.84 in (46.63 mm)
    depth
    1.41 in (35.81 mm)
    height
    6.00 in (152.36 mm)
    product weight
    8.82 lb(US) (4 kg)
    Environment
    measurement category
    Category III 277 V
    Category III 300 V
    electromagnetic compatibility
    Conducted and radiated emissions FCC part 15 class A
    Conducted and radiated emissions EN 61000-6-4
    Conducted and radiated emissions EN 61326 + A1
    Immunity to conducted disturbances EN 61000-6-2
    Immunity to conducted disturbances EN 61326-1
    Immunity to radiated fields EN 61000-6-2
    Immunity to radiated fields EN 61326-1
    IP degree of protection
    IP20 IEC 60529
    relative humidity
    0…95 %
    pollution degree
    2
    ambient air temperature for operation
    -22…158 °F (-30…70 °C)
    ambient air temperature for storage
    -40…185 °F (-40…85 °C)
    operating altitude
    < 9842.52 ft (3000 m)
    Ordering and shipping details
    Category
    09791 - POWERLOGIC ENERCEPT POWER METER
    Discount Schedule
    PL1
    GTIN
    00785901189084
    Package weight(Lbs)
    2.27 kg (5 lb(US))
    Returnability
    No
    Offer Sustainability
    California proposition 65
    WARNING: This product can expose you to chemicals which are known to the State of California to cause Carcinogen and Reproductive harm.For more information go to www.p65warnings.ca.gov
    EU RoHS Directive
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information.
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • View more View less

    Documents

    Language
    • English4
    CAD
    Format
    Size
    Date
    Add to My Documents
    EM4200_CAD (Version 1.0)
    Files in document
    igs
    32.2 MB
    pdf
    123.3 KB
    dxf
    2.6 MB
    Size zip
    Size 34.9 MB
    Date 12/21/15
    Files in document
    igs
    32.2 MB
    pdf
    123.3 KB
    dxf
    2.6 MB
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    METSEEM4236 : Enercept Meter, class 0.2S, Modbus/BACnet RS-485, user choice, ANSI wire code
    Description
    Enercept Meter, class 0.2S, Modbus/BACnet RS-485, user choice, ANSI wire code
    Size pdf
    Size 195.3 KB
    Date 1/23/20
    Description
    Enercept Meter, class 0.2S, Modbus/BACnet RS-485, user choice, ANSI wire code
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    METSEEM4236 : Enercept Meter, class 0.2S, Modbus/BACnet RS-485, user choice, ANSI wire code
    Description
    Enercept Meter, class 0.2S, Modbus/BACnet RS-485, user choice, ANSI wire code
    Size pdf
    Size 195.3 KB
    Date 1/23/20
    Description
    Enercept Meter, class 0.2S, Modbus/BACnet RS-485, user choice, ANSI wire code
    Technical leaflet
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 457.9 KB
    Date 4/27/19
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /