USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Select your location
View all PowerLogic PM8000 series
Schneider Eletric METSEPM8213 Picture

METSEPM8213

Schneider Eletric METSEPM8213 Picture
METSEPM8213

PowerLogic PM8000 - PM8213 LV DC - DIN rail mount meter - intermediate metering

Show more characteristics
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
  • Price*
    5,768.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    PowerLogic
    product name
    PowerLogic PM8000
    device short name
    PM8213
    product or component type
    Power meter
    Complementary
    power quality analysis
    EN 50160 2010 compliance report
    IEEE 519 2014 compliance report
    IEC 61000-4-30 class S power quality measurement
    up to the 63rd harmonic
    harmonic distortion
    waveform capture
    voltage sag and swell detection
    programmablity (logic and math functions)
    IEC 62586 power quality monitoring
    device application
    WAGES metering
    Power monitoring
    type of measurement
    Current
    Voltage
    Frequency
    Active and reactive power total
    Apparent power total
    Power factor total
    Active and reactive power per phase, rms
    Apparent power per phase, rms
    Power factor per phase, rms
    supply voltage
    20...60 V DC +/- 10 %
    network frequency
    60 Hz
    50 Hz
    Line Rated Current
    1 A
    10 A
    5 A
    poles description
    3P
    1P + N
    3P + N
    power consumption in W
    17 W
    display type
    Without display
    sampling rate
    256 samples/cycle
    measurement current
    50…10000 mA
    analogue input type
    voltage 5 MOhm)
    current 0.3 MOhm)
    measurement voltage
    57…400 V AC 42...69 Hz between phase and neutral
    100…690 V AC 42...69 Hz between phases
    frequency measurement range
    42…69 Hz
    number of inputs
    3 digital 30 V AC
    3 digital 60 V DC
    measurement accuracy
    Current +/- 0.1 %
    Voltage +/- 0.1 %
    Active energy +/- 0.2 %
    accuracy class
    Class 0.2S active energy IEC 62053-22
    Class 0.2 active energy ANSI C12.20
    Class 0.2 active power IEC 61557-12
    Class 0.5S reactive energy IEC 62053-24
    Class 0.5 power factor IEC 61557-12
    Class 0.2 voltage IEC 61557-12
    Class 0.2 current IEC 61557-12
    number of outputs
    1 pulse
    information displayed
    Voltage
    Current
    Frequency
    Power
    Energy consumption
    Harmonic distortion
    communication port protocol
    Modbus RTU 115 kbauds - 2-wire
    ION 115 kbauds - 2-wire
    DNP3
    IEC 61850
    Modbus TCP/IP
    Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s
    RSTP 801.1d 2004
    communication port support
    Ethernet
    Screw terminal block RS485
    communication network type
    IPv6 (internet protocol)
    data recording
    Event logs
    Min/max of instantaneous values
    Time stamping
    GPS synchronisation
    Alarm logs
    Data logs
    Trending/forecasting
    Sag and swell logs
    Waveform logs
    Sequence of event recording
    Harmonics logs
    memory capacity
    512 MB
    web services
    Customizable home page
    File upload/download via FTP
    File upload/download via SFTP
    Web server
    Alarm notification by e-mail
    Viewing of captured waveform (FTP)
    Viewing of captured waveform (web)
    HTTPS server
    communication service
    DHCP
    SNMP
    SMTP e-mail notification
    RSTP support
    NTP time synchronization
    PTP time synchronization
    cybersecurity
    Robust security logs
    Syslog protocol support
    Password protection
    Port hardening
    Enable/disable communication ports
    mounting mode
    Clip-on
    mounting support
    DIN rail
    installation category
    III
    Safety Construction
    III, 400…690 V IEC 61010-1:ed. 3
    III, 400…690 V EN 61010-1:ed. 3
    III, 347…600 V UL 61010-1:ed. 3
    III, 347…600 V CSA C22.2 No 61010-1:ed. 3
    standards
    IEC 62053-24
    IEC 62052-11
    IEC 61557-12
    IEC 62053-22
    IEEE 1588
    IEC 62586-2
    IEC 61326-1
    product certifications
    CE
    CULus
    N998
    China RoHS
    width
    3.56 in (90.5 mm)
    depth
    3.57 in (90.8 mm)
    height
    3.56 in (90.5 mm)
    net weight
    18.62 oz (528 g)
    Environment
    electromagnetic compatibility
    Electrostatic discharge IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3
    Electrical fast transient/burst immunity test IEC 61000-4-4
    Surge immunity test IEC 61000-4-5
    Conducted RF disturbances IEC 61000-4-6
    Magnetic field at power frequency IEC 61000-4-8
    Voltage dips and interruptions immunity test IEC 61000-4-11
    Immunity to impulse waves IEC 61000-4-12
    Conducted and radiated emissions EN 55022
    Conducted and radiated emissions EN 55011
    Conducted and radiated emissions FCC Part 15
    Conducted and radiated emissions ICES-003
    Conducted RF disturbances 2...150 Hz) CLC/TR 50579
    Surge withstand IEEE C37.90.1
    IP degree of protection
    IP30 IEC 60529
    relative humidity
    5…95 %
    ambient air temperature for operation
    -13…158 °F (-25…70 °C)
    ambient air temperature for storage
    -40…185 °F (-40…85 °C)
    operating altitude
    9842.52 ft (3000 m)
    Ordering and shipping details
    Category
    09797 - POWERLOGIC PM8000 HARDWARE
    Discount Schedule
    PL1
    Package weight(Lbs)
    3.63 kg (8 lb(US))
    Returnability
    No
    Offer Sustainability
    California proposition 65
    WARNING: This product can expose you to chemicals including: Dichloromethane (Methylene chloride) and Bisphenol A (BPA) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • View more View less

    Documents

    Language
    • All Languages12
    • English11
    • Chinese2
    • French3
    • German2
    • Italian2
    • Portuguese2
    • Russian2
    • Spanish2
    User guide
    Format
    Size
    Date
    Add to My Documents
    PM8000 series user manual (Version 06)
    Description
    The document explains the configuration and operation of the PM8000 series meters.
    Size pdf
    Size 5 MB
    Date 11/1/19
    Description
    The document explains the configuration and operation of the PM8000 series meters.
    Upgrade meter firmware to v2.2.1 (Version 03)
    Description
    This document describes the process to upgrade PowerLogic™ ION9000, PM8000 or ION7400 series meters to the latest firmware version. It also contains information about upgrading analog I/O option module firmware.
    Size pdf
    Size 947.6 KB
    Date 11/1/19
    Description
    This document describes the process to upgrade PowerLogic™ ION9000, PM8000 or ION7400 series meters to the latest firmware version. It also contains information about upgrading analog I/O option module firmware.
    What’s new for Power and Energy Monitoring Systems — November 2019 (Version 00)
    Description
    This update provides a summary of technological advances in the Power and Energy Monitoring System offers, and the technical documentation accompanying their release.
    Size pdf
    Size 95.2 KB
    Date 11/1/19
    Description
    This update provides a summary of technological advances in the Power and Energy Monitoring System offers, and the technical documentation accompanying their release.
    Upgrade PM89RD96 display firmware to v4.0.15 (Version 03)
    Description
    This document describes the process to upgrade RD96 display firmware to the latest version for use with PowerLogic™ ION9000, PM8000 or ION7400 series meters.
    Size pdf
    Size 167.3 KB
    Date 11/1/19
    Description
    This document describes the process to upgrade RD96 display firmware to the latest version for use with PowerLogic™ ION9000, PM8000 or ION7400 series meters.
    IEC 61000-4-30 compliance and ION meters (Version 13)
    Description
    This technical note outlines the compliance of applicable PowerLogic meters with the International Electrotechnical Commission’s IEC 61000-4-30 (or “4-30”) standard, and is intended for personnelwith knowledge of power quality and power quality standards.
    Size pdf
    Size 112.4 KB
    Date 9/1/19
    Description
    This technical note outlines the compliance of applicable PowerLogic meters with the International Electrotechnical Commission’s IEC 61000-4-30 (or “4-30”) standard, and is intended for personnelwith knowledge of power quality and power quality standards.
    What’s new in PM8000 series meter firmware v2.1.0 (Version 00)
    Description
    Whats New in PM8000 v2.1.0 firmware. The following new features are included: Enhanced firmware upgrades, PTP time synchronization, Secure webserver (HTTPS), other
    Size pdf
    Size 92.4 KB
    Date 2/1/19
    Description
    Whats New in PM8000 v2.1.0 firmware. The following new features are included: Enhanced firmware upgrades, PTP time synchronization, Secure webserver (HTTPS), other
    ION Reference -EN (Version 10)
    Description
    Overview of ION architecture and details of all ION modules
    Size pdf
    Size 9.5 MB
    Date 10/26/18
    Description
    Overview of ION architecture and details of all ION modules
    Série PowerLogic PM8000 Manuel de l'utilisateur (Version 03)
    Description
    Série PowerLogic PM8000 Manuel de l'utilisateur
    Size pdf
    Size 5.3 MB
    Date 2/8/18
    Description
    Série PowerLogic PM8000 Manuel de l'utilisateur
    Instruction Sheet
    Format
    Size
    Date
    Add to My Documents
    PowerLogic Analog I/O option module (Version 00)
    Description
    Installation instructions
    Size pdf
    Size 5.3 MB
    Date 3/1/19
    Description
    Installation instructions
    PowerLogic PM8213/8243 installation guide - EN-ES-FR-DE-IT-PT- (Version 03)
    Description
    The installation guide for PowerLogic PM8243 power and energy DIN-mount meter describes mounting, wiring, connecting and verifying operation of the meter.
    Size pdf
    Size 3.1 MB
    Date 2/8/18
    Description
    The installation guide for PowerLogic PM8243 power and energy DIN-mount meter describes mounting, wiring, connecting and verifying operation of the meter.
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    METSEPM8213 : PowerLogic PM8000 - PM8213 LV DC - DIN rail mount meter - intermediate metering
    Description
    PowerLogic PM8000 - PM8213 LV DC - DIN rail mount meter - intermediate metering
    Size pdf
    Size 195.3 KB
    Date 12/16/19
    Description
    PowerLogic PM8000 - PM8213 LV DC - DIN rail mount meter - intermediate metering
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    METSEPM8213 : PowerLogic PM8000 - PM8213 LV DC - DIN rail mount meter - intermediate metering
    Description
    PowerLogic PM8000 - PM8213 LV DC - DIN rail mount meter - intermediate metering
    Size pdf
    Size 195.3 KB
    Date 12/16/19
    Description
    PowerLogic PM8000 - PM8213 LV DC - DIN rail mount meter - intermediate metering
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /