USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Select your location
View all Zelio Time
Schneider Eletric RE17LMBM Picture

RE17LMBM

Green premium brand logo
Schneider Eletric RE17LMBM Picture
RE17LMBM
Green premium brand logo

time delay relay 10 functions - 1 s..100 h - 24..240 VAC - solid state output

Show more characteristics
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price*
    62.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Zelio Time
    product or component type
    Modular timing relay
    discrete output type
    Solid state
    width
    0.69 in (17.5 mm)
    component name
    RE17L
    time delay type
    D
    A
    B
    H
    Ac
    At
    Ht
    Di
    C
    Bw
    time delay range
    1...10 s
    6...60 s
    6...60 min
    1...10 h
    10...100 h
    1...10 min
    0.1...1 s
    nominal output current
    0.7 A
    Complementary
    control type
    Selector switch front panel
    [Us] rated supply voltage
    24...240 V AC 50/60 Hz
    voltage range
    0.85...1.1 Us
    supply frequency
    50...60 Hz +/- 5 %
    release of input voltage
    8 V
    control signal pulse width
    0.05 s typical
    insulation resistance
    100 MOhm 500 V DC IEC 60664-1
    [Uimp] rated impulse withstand voltage
    5 kV 1.2/50 µs
    power on delay
    100 ms
    connections - terminals
    Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end
    Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
    Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
    tightening torque
    5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1
    dielectric strength
    2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
    housing material
    Self-extinguishing
    repeat accuracy
    +/- 0.5 % IEC 61812-1
    temperature drift
    +/- 0.05 %/°C
    voltage drift
    +/- 0.2 %/V
    setting accuracy of time delay
    +/- 10 % of full scale 25 °C IEC 61812-1
    reset time
    350 ms on de-energisation typical
    on-load factor
    100 %
    power consumption in VA
    0…3 VA 240 V AC
    maximum power consumption in W
    1.5 W 240 V DC
    breaking capacity
    0.5 A AC/DC UL
    0.7 A AC/DC 68 °F (20 °C)
    operating frequency
    10 Hz
    maximum output current
    20 A <= 10 ms
    minimum switching current
    10 mA
    maximum leakage current
    5 mA
    maximum switching voltage
    250 V AC
    maximum voltage drop
    <4 V 3-wire
    <8 V 2-wire
    electrical durability
    100000000 cycles
    marking
    CE
    creepage distance
    4 kV/3 IEC 60664-1
    safety reliability data
    MTTFd = 353.8 years
    B10d = 320000
    mounting position
    Any position in relation to normal vertical mounting plane
    mounting support
    35 mm DIN rail EN/IEC 60715
    net weight
    0.15 lb(US) (0.068 kg)
    time delay type
    A, Ac, At, B, Bw, C, D, Di, H, Ht
    functionality
    Multifunction
    compatibility code
    RE17
    Environment
    immunity to microbreaks
    20 ms
    derating factor
    5 mA/°C
    standards
    2004/108/EC
    EN 61000-6-2
    IEC 61812-1
    EN 61000-6-4
    EN 61000-6-1
    2006/95/EC
    EN 61000-6-3
    product certifications
    GL
    CULus
    CSA
    ambient air temperature for storage
    -22…140 °F (-30…60 °C)
    ambient air temperature for operation
    -4…140 °F (-20…60 °C)
    IP degree of protection
    IP20 IEC 60529 terminal block)
    IP40 IEC 60529 housing)
    IP50 IEC 60529 front panel)
    vibration resistance
    20 m/s² 10…150 Hz)IEC 60068-2-6
    shock resistance
    15 gn 11 ms IEC 60068-2-27
    relative humidity
    93 % without condensation IEC 60068-2-30
    electromagnetic compatibility
    Electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2
    Electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2
    Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3
    Electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4
    Electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4
    1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5
    1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5
    Conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6
    Voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11
    Voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11
    Conducted and radiated emissionsclass B EN 55022
    Ordering and shipping details
    Category
    22370 - RE, RM MISC TIMERS & COUNTERS
    Discount Schedule
    CP2
    GTIN
    00785901285878
    Package weight(Lbs)
    0.07 kg (0.16 lb(US))
    Returnability
    Yes
    Country of origin
    ID
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
  • View more View less

    Documents

    Language
    • English5
    Catalog
    Format
    Size
    Date
    Add to My Documents
    Digest 178 Catalog 23: Relays and Timers (Version 1.0)
    Description
    Section 23 of Digest 178 Catalog includes selection information for general purpose relays, industrial relays, solid state relays, timers, control and measurement relays, power supplies and Zelio™ interface modules.and legacy relays. Replaces Digest 177 section 23; 0100CT1501_SEC-23
    Size pdf
    Size 6 MB
    Date 5/12/19
    Description
    Section 23 of Digest 178 Catalog includes selection information for general purpose relays, industrial relays, solid state relays, timers, control and measurement relays, power supplies and Zelio™ interface modules.and legacy relays. Replaces Digest 177 section 23; 0100CT1501_SEC-23
    Size pdf
    Size 7.8 MB
    Date 1/14/19
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    time delay relay 10 functions - 1 s..100 h - 24..240 VAC - solid state output
    Description
    time delay relay 10 functions - 1 s..100 h - 24..240 VAC - solid state output
    Size pdf
    Size 195.3 KB
    Date 12/16/19
    Description
    time delay relay 10 functions - 1 s..100 h - 24..240 VAC - solid state output
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    time delay relay 10 functions - 1 s..100 h - 24..240 VAC - solid state output
    Description
    time delay relay 10 functions - 1 s..100 h - 24..240 VAC - solid state output
    Size pdf
    Size 195.3 KB
    Date 12/16/19
    Description
    time delay relay 10 functions - 1 s..100 h - 24..240 VAC - solid state output
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    time delay relay 10 functions - 1 s..100 h - 24..240 VAC - solid state output
    Description
    time delay relay 10 functions - 1 s..100 h - 24..240 VAC - solid state output
    Size pdf
    Size 195.3 KB
    Date 12/16/19
    Description
    time delay relay 10 functions - 1 s..100 h - 24..240 VAC - solid state output
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Width 17.5 mm



  • Connections and Schema

    Internal Wiring Diagram



    Wiring Diagram


    (1) Contact Y1:

    • Control for functions B, C, Ac, Bw.

    • Partial stop for functions At, Ht.

    • Function D if Di selected.

    • Not used for functions A and H.


  • Technical Description

    Function A : Power on Delay Relay
    Description

    The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous.

    Function: 1 Output


    Function: 2 Outputs


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function Ac: On-Delay & Off-Delay with Control Signal
    Description

    After energisation of power supply and energization of Y1 causes the timing period T to start.

    At the end of this timing period, the output(s) R close(s).

    When deenergization of Y1, the timing T starts.

    At the end of this timing period T,the output(s) R revert(s) to its/their initial position.

    The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    Function: 2 Outputs



    Function At : Power on Delay Relay (Summation) with Control Signal
    Description

    After power-up, the first opening of control contact C starts the timing. Timing can be interrupted each time control contact closes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output relay closes.

    Function: 1 Output


    T = t1 + t2 +...


    Function B : Interval Relay with Control Signal
    Description

    After power-up, pulsing or maintaining control contact C starts the timing T. The output R closes for the duration of the timing period T then reverts to its initial state.

    Function: 1 Output



    Function Bw : Double Interval Relay with Control Signal
    Description

    On closing and opening of control contact C, the output R closes for the duration of the timing period T.

    Function: 1 Output



    Function C : Off-Delay Relay with Control Signal
    Description

    After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the timing period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.

    Function: 1 Output


    Function: 2 Outputs


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function D: Symmetrical Flashing Relay (Starting Pulse Off)
    Description

    On energisation of power supply, output(s) R starts at its/their initial state for timing duration T then change(s) to output(s) R close(s) for the same timing duration T.This cycle is repeated indefintely until power supply removal.Specially for RE17*, RE22R2AMU, RE22R2MMW, RE22R2MMU, RE22R2MJU,this D function can only be initiated by energizing Y1 permanently.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    Function: 2 Outputs


    Function: 1 Output with Retrigger / Restart Control


    Function: 2 Output with Retrigger / Restart Control



    Function Di : Symmetrical Flasher Relay (Starting Pulse On)
    Description

    Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.

    The second output can be either timed or instantaneous.

    Function: 1 Output


    Function: 2 Outputs


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function H : Interval Relay
    Description

    On energisation of the relay, timing period T starts and the output(s) R close(s). At the end of the timing period T, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.

    Function: 1 Output


    Function: 2 Outputs


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function Ht : Interval Relay (Summation) with Control Signal
    Description

    On energisation, the output R closes for the duration of a timing period T then reverts to its initial state.

    Pulsing or maintaining control contact C will again close the output R.

    Timing T is only active when control contact C is released and so the output R will not revert to its initial state until after a time t1 + t2 +...

    The relay memorises the total, cumulative opening time of control contact C and, once the set time T is reached, the output R reverts to its initial state.

    Function: 1 Output


    T = t1 + t2 +...


    Legend

    Relay de-energised

    Relay energised

    Output open

    Output closed

    C

    Control contact

    G

    Gate

    R

    Relay or solid state output

    R1/R2

    2 timed outputs

    R2 inst.

    The second output is instantaneous if the right position is selected

    T

    Timing period

    Ta -

    Adjustable On-delay

    Tr -

    Adjustable Off-delay

    U

    Supply


Compare products: /