USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Select your location
View all Zelio Time
Schneider Eletric RE17RHMU Picture

RE17RHMU

Green premium brand logo
Schneider Eletric RE17RHMU Picture
RE17RHMU
Green premium brand logo

on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC

Show more characteristics
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price*
    42.90 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Zelio Time
    product or component type
    Modular timing relay
    discrete output type
    Relay
    width
    0.69 in (17.5 mm)
    device short name
    RE17R
    time delay type
    H
    Ht
    time delay range
    10...100 h
    0.1...1 s
    6...60 min
    1...10 s
    1...10 min
    6...60 s
    1...10 h
    nominal output current
    8 A
    Complementary
    contacts type and composition
    1 C/O
    contacts material
    Cadmium free
    height
    3.54 in (90 mm)
    depth
    2.83 in (72 mm)
    control type
    Selector switch front panel
    [Us] rated supply voltage
    24...240 V AC 50/60 Hz
    24 V DC
    voltage range
    0.85...1.1 Us
    supply frequency
    50...60 Hz +/- 5 %
    release of input voltage
    10 V
    connections - terminals
    Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end
    Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
    Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
    tightening torque
    5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1
    housing material
    Self-extinguishing
    repeat accuracy
    +/- 0.5 % IEC 61812-1
    temperature drift
    +/- 0.05 %/°C
    voltage drift
    +/- 0.2 %/V
    setting accuracy of time delay
    +/- 10 % of full scale 25 °C IEC 61812-1
    control signal pulse width
    100 ms with load in parallel typical
    30 ms typical
    insulation resistance
    100 MOhm 500 V DC IEC 60664-1
    reset time
    120 ms on de-energisation typical
    on-load factor
    100 %
    power consumption in VA
    0…32 VA 240 V AC
    maximum power consumption in W
    0.6 W 24 V DC
    minimum switching current
    10 mA 5 V DC
    maximum switching current
    8 A AC/DC
    maximum switching voltage
    250 V AC
    breaking capacity
    2000 VA
    operating frequency
    10 Hz
    electrical durability
    100000 cycles resistive 8 A 250 V AC
    mechanical durability
    10000000 cycles
    dielectric strength
    2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
    [Uimp] rated impulse withstand voltage
    5 kV 1.2/50 µs
    power on delay
    100 ms
    marking
    CE
    creepage distance
    4 kV/3 IEC 60664-1
    safety reliability data
    B10d = 270000
    MTTFd = 296.8 years
    mounting position
    Any position in relation to normal vertical mounting plane
    mounting support
    35 mm DIN rail EN/IEC 60715
    local signalling
    LED indicator on steady: relay energised, no timing in progress
    LED indicator 80 % ON and 20 % OFF flashing: timing in progress
    LED indicator 5 % ON and 95 % OFF pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L)
    net weight
    0.15 lb(US) (0.07 kg)
    time delay type
    H, Ht
    functionality
    On-delay timing
    compatibility code
    RE17
    Environment
    immunity to microbreaks
    20 ms
    standards
    EN 61000-6-4
    EN 61000-6-1
    2006/95/EC
    EN 61000-6-3
    IEC 61812-1
    2004/108/EC
    EN 61000-6-2
    product certifications
    CULus
    CSA
    GL
    ambient air temperature for storage
    -22…140 °F (-30…60 °C)
    ambient air temperature for operation
    -4…140 °F (-20…60 °C)
    IP degree of protection
    IP20 IEC 60529 terminal block)
    IP40 IEC 60529 housing)
    IP50 IEC 60529 front panel)
    vibration resistance
    20 m/s² 10…150 Hz)IEC 60068-2-6
    shock resistance
    15 gn 11 ms IEC 60068-2-27
    relative humidity
    93 % without condensation IEC 60068-2-30
    electromagnetic compatibility
    Electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2
    Electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2
    Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3
    Electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4
    Electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4
    1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5
    1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5
    Conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6
    Voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11
    Voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11
    Conducted and radiated emissionsclass B EN 55022
    Ordering and shipping details
    Category
    22370 - RE, RM MISC TIMERS & COUNTERS
    Discount Schedule
    CP2
    GTIN
    00785901301127
    Package weight(Lbs)
    0.08 kg (0.17 lb(US))
    Returnability
    Yes
    Country of origin
    ID
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    California proposition 65
    WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
  • View more View less

    Documents

    Language
    • All Languages12
    • English11
    • Chinese1
    • French2
    • German1
    • Italian1
    • Spanish1
    Catalog
    Format
    Size
    Date
    Add to My Documents
    Digest 178 Catalog 23: Relays and Timers (Version 1.0)
    Description
    Section 23 of Digest 178 Catalog includes selection information for general purpose relays, industrial relays, solid state relays, timers, control and measurement relays, power supplies and Zelio™ interface modules.and legacy relays. Replaces Digest 177 section 23; 0100CT1501_SEC-23
    Size pdf
    Size 6 MB
    Date 5/12/19
    Description
    Section 23 of Digest 178 Catalog includes selection information for general purpose relays, industrial relays, solid state relays, timers, control and measurement relays, power supplies and Zelio™ interface modules.and legacy relays. Replaces Digest 177 section 23; 0100CT1501_SEC-23
    Size pdf
    Size 7.8 MB
    Date 1/14/19
    Size pdf
    Size 7.4 MB
    Date 2/11/19
    Certificate
    Format
    Size
    Date
    Add to My Documents
    CCC Certificate Timer RE10 RE17 iRT (Version 1.0)
    Description
    CCC Certificate 2013010303640463
    Size pdf
    Size 1.7 MB
    Date 5/5/19
    Description
    CCC Certificate 2013010303640463
    UL Listed RE17, RE22, REXL, RE48A, RE88857, RE88865, RE88867, RENF22R2MMW (Version 1.0)
    Files in document
    pdf
    473.4 KB
    pdf
    475.7 KB
    Description
    NRNT_NRNT7_E173076_Timer New NFC Timer RENF22R2MMW
    Size zip
    Size 949 KB
    Date 5/19/15
    Files in document
    pdf
    473.4 KB
    pdf
    475.7 KB
    Description
    NRNT_NRNT7_E173076_Timer New NFC Timer RENF22R2MMW
    Instruction Sheet
    Format
    Size
    Date
    Add to My Documents
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 242.8 KB
    Date 4/20/16
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 1.4 MB
    Date 9/1/16
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC
    Description
    on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC
    Size pdf
    Size 195.3 KB
    Date 11/20/19
    Description
    on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 414.1 KB
    Date 9/1/16
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC
    Description
    on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC
    Size pdf
    Size 195.3 KB
    Date 11/20/19
    Description
    on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC
    Description
    on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC
    Size pdf
    Size 195.3 KB
    Date 11/20/19
    Description
    on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Width 17.5 mm



  • Connections and Schema

    Internal Wiring Diagram



    Wiring Diagram



  • Technical Description

    Function H : Interval Relay
    Description

    On energisation of the relay, timing period T starts and the output(s) R close(s). At the end of the timing period T, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.

    Function: 1 Output


    Function: 2 Outputs


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function Ht : Interval Relay (Summation) with Control Signal
    Description

    On energisation, the output R closes for the duration of a timing period T then reverts to its initial state.

    Pulsing or maintaining control contact C will again close the output R.

    Timing T is only active when control contact C is released and so the output R will not revert to its initial state until after a time t1 + t2 +...

    The relay memorises the total, cumulative opening time of control contact C and, once the set time T is reached, the output R reverts to its initial state.

    Function: 1 Output


    T = t1 + t2 +...


    Legend

    Relay de-energised

    Relay energised

    Output open

    Output closed

    C

    Control contact

    G

    Gate

    R

    Relay or solid state output

    R1/R2

    2 timed outputs

    R2 inst.

    The second output is instantaneous if the right position is selected

    T

    Timing period

    Ta -

    Adjustable On-delay

    Tr -

    Adjustable Off-delay

    U

    Supply


Compare products: /