USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Select your location
View all Zelio Time
Schneider Eletric RE22R2MMU Picture

RE22R2MMU

Green premium brand logo
Schneider Eletric RE22R2MMU Picture
RE22R2MMU
Green premium brand logo

Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O

Show more characteristics
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
  • Price*
    64.50 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Zelio Time
    product or component type
    Modular timing relay
    discrete output type
    Relay
    device short name
    RE22
    nominal output current
    8 A
    Complementary
    contacts type and composition
    1 C/O timed contact
    1 C/O timed or instantaneous contact
    time delay type
    Ht
    At
    Bw
    C
    Di
    B
    Ac
    H
    A
    D
    time delay range
    10...100 h
    6...60 s
    0.1...1 s
    1...10 h
    1...10 s
    1...10 min
    6...60 min
    control type
    Rotary knob front panel
    [Us] rated supply voltage
    24...240 V AC
    24 V DC
    voltage range
    0.85...1.1 Us
    supply frequency
    50...60 Hz +/- 5 %
    connections - terminals
    Screw terminals, 2 x 1.5 mm² with cable end
    Screw terminals, 2 x 2.5 mm² without cable end
    tightening torque
    5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1
    housing material
    Self-extinguishing
    repeat accuracy
    +/- 0.5 % IEC 61812-1
    temperature drift
    +/- 0.05 %/°C
    voltage drift
    +/- 0.2 %/V
    setting accuracy of time delay
    +/- 10 % of full scale 25 °C IEC 61812-1
    Control signal pulse width
    30 ms
    100 ms under load
    insulation resistance
    100 MOhm 500 V DC IEC 60664-1
    Recovery time
    120 ms on de-energisation
    immunity to microbreaks
    10 ms
    power consumption in VA
    50 VA 240 V AC
    power consumption in W
    0.7 W 24 V DC
    breaking capacity
    2000 VA
    minimum switching current
    10 mA 5 V
    maximum switching current
    8 mA
    maximum switching voltage
    250 V
    electrical durability
    100000 cycles resistive, 8 A 250 V, AC
    mechanical durability
    10000000 cycles
    Rated impulse withstand voltage
    5 kV 1.2…50 µs IEC 60664-1
    5 kV IEC 61812-1
    Power on delay
    100 ms
    safety reliability data
    MTTFd = 182.6 years
    B10d = 170000
    mounting position
    Any position in relation to normal vertical mounting plane
    mounting support
    35 mm DIN rail EN/IEC 60715
    status LED
    Green LED flashing)timing in progress
    Green LED steady)power ON
    Yellow LEDrelay energised
    width
    0.89 in (22.5 mm)
    net weight
    0.20 lb(US) (0.09 kg)
    Environment
    dielectric strength
    2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
    standards
    IEC 61812-1
    EN 61000-6-1
    EN 61000-6-2
    EN 61000-6-3
    EN 61000-6-4
    directives
    2004/108/EC - electromagnetic compatibility
    2006/95/EC - low voltage directive
    product certifications
    CULus
    CSA
    CE
    China RoHS
    CCC
    RCM
    GL
    EAC
    ambient air temperature for operation
    -4…140 °F (-20…60 °C)
    ambient air temperature for storage
    -22…140 °F (-30…60 °C)
    IP degree of protection
    Housing IP40 IEC 60529
    Terminal block IP20 IEC 60529
    Front face IP40 IEC 60529
    vibration resistance
    20 m/s² 10…150 Hz)IEC 60068-2-6
    shock resistance
    15 gn 11 ms IEC 60068-2-27
    relative humidity
    93 %, without condensation IEC 60068-2-30
    electromagnetic compatibility
    Electrostatic discharge immunity test 6 kV contact discharge)level 3 EN/IEC 61000-4-2
    Electrostatic discharge immunity test 8 kV air discharge)level 3 EN/IEC 61000-4-2
    Fast transients immunity test 1 kV capacitive connecting clip)level 3 IEC 61000-4-4
    Fast transients immunity test 2 kV direct contact)level 3 IEC 61000-4-4
    Surge immunity test 1 kV differential mode)level 3 IEC 61000-4-5
    Surge immunity test 2 kV common mode)level 3 IEC 61000-4-5
    Radiated radio-frequency electromagnetic field immunity test 10 V 0.15...80 MHz)level 3 IEC 61000-4-6
    Electromagnetic field immunity test 10 V/m 80 MHz...1 GHz)level 3 IEC 61000-4-3
    Immunity to microbreaks and voltage drops 30 % 500 ms) IEC 61000-4-11
    Immunity to microbreaks and voltage drops 100 % 20 ms) IEC 61000-4-11
    Conducted and radiated emissionsclass B EN 55022
    Ordering and shipping details
    Category
    22376 - RELAYS-MEASUREMENT(RM4)
    Discount Schedule
    CP2
    GTIN
    00785901507352
    Package weight(Lbs)
    0.09 kg (0.2 lb(US))
    Returnability
    No
    Country of origin
    ID
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    California proposition 65
    WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
  • View more View less

    Documents

    Language
    • All Languages13
    • English12
    • Chinese3
    • French4
    • German3
    • Italian3
    • Spanish3
    Catalog
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 7.8 MB
    Date 1/14/19
    Size pdf
    Size 7.4 MB
    Date 2/11/19
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD file (on TraceParts) for RE22R2MMU: Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for RE22R2MMU: Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    Size zip
    Size 1,003.3 KB
    Date 2/18/14
    Files in document
    Certificate
    Format
    Size
    Date
    Add to My Documents
    Zelio Timer RE22 and RENF22R2MMW (Version 1.0)
    Description
    RE22 and RENF22R2MMW CCC Certificate 2014010303687033
    Size pdf
    Size 1.7 MB
    Date 5/23/19
    Description
    RE22 and RENF22R2MMW CCC Certificate 2014010303687033
    UL Listed RE17, RE22, REXL, RE48A, RE88857, RE88865, RE88867, RENF22R2MMW (Version 1.0)
    Files in document
    pdf
    473.4 KB
    pdf
    475.7 KB
    Description
    NRNT_NRNT7_E173076_Timer New NFC Timer RENF22R2MMW
    Size zip
    Size 949 KB
    Date 5/19/15
    Files in document
    pdf
    473.4 KB
    pdf
    475.7 KB
    Description
    NRNT_NRNT7_E173076_Timer New NFC Timer RENF22R2MMW
    Instruction Sheet
    Format
    Size
    Date
    Add to My Documents
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    EU DOC - Zelio Timer RE22 (Version 1.0)
    Description
    Manufacturer DOC-RE22 Juret/Sprint2 series
    Size pdf
    Size 243.3 KB
    Date 4/20/16
    Description
    Manufacturer DOC-RE22 Juret/Sprint2 series
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    RE22R2MMU_ROHS_DECLARATION
    Description
    RE22R2MMU_ROHS_DECLARATION
    Size pdf
    Size 195.3 KB
    Date 11/21/19
    Description
    RE22R2MMU_ROHS_DECLARATION
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    RE22R2MMU_REACH_DECLARATION
    Description
    RE22R2MMU_REACH_DECLARATION
    Size pdf
    Size 195.3 KB
    Date 11/21/19
    Description
    RE22R2MMU_REACH_DECLARATION
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    RE22R2MMU_ROHS_CHINA_DECLARATION
    Description
    RE22R2MMU_ROHS_CHINA_DECLARATION
    Size pdf
    Size 195.3 KB
    Date 11/21/19
    Description
    RE22R2MMU_ROHS_CHINA_DECLARATION
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



  • Connections and Schema

    Internal Wiring Diagram



    Wiring Diagram



  • Technical Description

    Function A : Power on Delay Relay
    Description

    The timing period T begins on energization. After timing, the output(s) relay close(s).


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function Ac : On- and Off-Delay Relay with Control Signal
    Description

    After power-up, closing of the control contact Y1 causes the timing period T to start (timing can be interrupted by operating the Gate control contact G). At the end of this timing period, the relay closes.

    When control contact Y1 re-opens, the timing T starts.At the end of this timing period T

    At the end of this timing period T, the output reverts to its initial position (timing can be interrupted by operating the Gate control contact G).


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function At : Power on Delay Relay (Summation) with Control Signal
    Description

    After power-up, the first opening of control contact Y1 starts the timing. Timing can be interrupted each time control contact closes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output relay closes.


    T = t1+t2+t3


    Function B : Interval Relay with Control Signal
    Description

    After power-up, pulsing or maintaining control contact Y1 starts the timing T. The output relay closes for the duration of the timing period T then reverts to its initial state.



    Function Bw : Double Interval Relay with Control Signal
    Description

    On closing and opening of control contact Y1, the output relay closes for the duration of the timing period T.



    Function C : Off-Delay Relay with Control Signal
    Description

    After power-up and closing of the control contact Y1, the output relay closes. When control contact Y1 re-opens, timing T starts. At the end of the timing period, the output(s) relay revert(s) to its/their initial state.


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function D : Symmetrical Flasher Relay (Starting Pulse Off)
    Description

    Repetitive cycle with two timing periods T of equal duration, with output(s) relay changing state at the end of each timing period T.


    Before power-up Y1 should be permanently connected to A1.

    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function D : Symmetrical Flasher Relay (Starting Pulse On)
    Description

    Repetitive cycle with two timing periods T of equal duration, with output(s) relay changing state at the end of each timing period T.


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function H : Interval Relay
    Description

    On energization of the relay, timing period T starts and the output(s) relay close(s). At the end of the timing period T, the output(s) relay revert(s) to its/their initial state


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)

    Legend

    Relay de-energised

    Relay energised

    Output open

    Output closed

    Y1 :

    Control contact

    R1/R2 :

    2 timed outputs

    R2 inst. :

    The second output is instantaneous if the right position is selected

    T :

    Timing period

    U :

    Supply


    Function Ht : Interval Relay (Summation) with Control Signal
    Description

    On energization, the output relay closes for the duration of a timing period T then reverts to its initial state.

    Pulsing or maintaining control contact Y1 will again close the output relay.

    Timing T is only active when control contact Y1 is released and so the output relay will not revert to its initial state until after a time t1 + t2 + t3

    The relay memories the total, cumulative opening time of control contact Y1 and, once the set time T is reached, the output relay reverts to its initial state.


    T = t1+t2+t3

    Legend

    Relay de-energised

    Relay energised

    Output open

    Output closed

    Y1 :

    Control contact

    R1/R2 :

    2 timed outputs

    R2 inst. :

    The second output is instantaneous if the right position is selected

    T :

    Timing period

    U :

    Supply


Compare products: /