Schneider Electric USA Website

Welcome to our website.

Select your location

View all   Zelio Control
Schneider Eletric RM35S0MW Picture

RM35S0MW

Green premium brand logo
Schneider Eletric RM35S0MW Picture
RM35S0MW
Green premium brand logo

speed control relay RM35-S - 24..240 V AC/DC

Show more characteristics
  • Product availability
    Stock - Normally stocked in distribution facility
  • 217.00 USD
    Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    Zelio Control
    product or component type
    Modular measurement and control relays
    relay type
    Speed control relays
    relay name
    RM35S
    relay monitored parameters
    Overspeed
    Underspeed
    time delay range
    0.6...60 s adjustable on energisation 0...10 % of the full scale value)
    switching capacity in VA
    1250 VA
    minimum switching current
    10 mA 5 V DC
    [Us] rated supply voltage
    24...240 V AC/DC
    maximum power consumption in VA
    5 VA AC
    measurement range
    0.05...0.5 s
    0.5...5 min
    1...10 min
    1...10 s
    0.5...5 s
    0.1...1 s
    0.1...1 min
    utilisation category
    AC-12 IEC 60947-5-1
    AC-13 IEC 60947-5-1
    AC-14 IEC 60947-5-1
    AC-15 IEC 60947-5-1
    DC-12 IEC 60947-5-1
    DC-13 IEC 60947-5-1
    DC-14 IEC 60947-5-1
    Complementary
    rest time in memory mode
    50 ms contact S2 in memory mode on time delay
    1 s supply Un in memory mode on time delay
    maximum switching voltage
    250 V AC/DC
    supply voltage limits
    20.4…264 V AC/DC
    maximum power consumption in W
    3 W DC
    width
    1.38 in (35 mm)
    output contacts
    1 C/O
    contacts material
    Cadmium free
    nominal output current
    5 A
    delay at power up
    0.05 s
    hysteresis
    5 % threshold
    measurement accuracy
    +/- 10 % of the full scale value
    repeat accuracy
    +/- 0.5 % input and measurement circuit
    +/- 0.5 % time delay
    measurement error
    +/- 0.1 %/°C with temperature variation
    < +/- 1 % over the whole range with voltage variation
    input frequency
    0.0017…20 Hz
    response time
    15 ms max on crossing the threshold)
    polarity
    Reversible polarity on DC supply
    threshold setting
    10...100 %
    supply voltage for sensor
    11.5...12.5 V
    maximum supply current for sensors
    40 mA < 24 V AC 77 °F (25 °C)
    40 mA < 24 V DC 77 °F (25 °C)
    50 mA 24...240 V AC
    50 mA 24...240 V DC
    impulse duration
    >= 5 ms high state
    >= 5 ms low state
    input compatibility
    3-wire sensor (E1) PNP or NPN, 12 V, 50 mA
    NAMUR sensor (E2), 12 V, 1.5 kOhm
    Voltage input (E1), 0...30 V, 9.5 kOhm >= 4.5 V <= 1 V
    Volt-free contact input (E1), 12 V, 9.5 kOhm
    marking
    CE : EMC 89/336/EEC
    CE : 73/23/EEC
    overvoltage category
    III IEC 60664-1
    insulation resistance
    > 500 MOhm 500 V DC between supply and relay output IEC 60255-5
    > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1
    > 1 MOhm 500 V DC between supply and measurement IEC 60255-5
    > 500 MOhm 500 V DC between supply and relay output IEC 60664-1
    > 500 MOhm 500 V DC between measurement and relay output IEC 60255-5
    > 1 MOhm 500 V DC between supply and measurement IEC 60664-1
    [Ui] rated insulation voltage
    250 V IEC 60664-1
    operating voltage tolerance
    - 15 % + 10 % Un
    supply frequency
    50/60 Hz +/- 10 %
    operating position
    Any position without derating
    connections - terminals
    Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end
    Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
    Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end
    Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
    tightening torque
    5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1
    housing material
    Self-extinguishing plastic
    status LED
    1 LED Green power ON
    1 LED Yellow inhibit
    1 LED Yellow relay (R)
    mounting support
    35 mm symmetrical DIN rail EN/IEC 60715
    electrical durability
    100000 cycles
    mechanical durability
    30000000 cycles
    operating rate
    <= 360 operations/hour full load
    Environment
    immunity to microbreaks
    50 ms
    electromagnetic compatibility
    Emission standard for industrial environments EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3
    Immunity for industrial environments NF EN/IEC 61000-6-2
    standards
    NF EN 60255-6
    IEC 60255-6
    product certifications
    C-tick
    GOST
    UL
    GL
    CSA
    ambient air temperature for storage
    -40…158 °F (-40…70 °C)
    ambient air temperature for operation
    -4…122 °F (-20…50 °C)
    relative humidity
    95 % 131 °F (55 °C) IEC 60068-2-30
    vibration resistance
    0.35 mm 5…57.6 Hz)IEC 60068-2-6/IEC 60255-21-1
    1 gn 57.6…150 Hz)IEC 60068-2-6/IEC 60255-21-1
    shock resistance
    15 gn 11 ms IEC 60255-21-1
    IP degree of protection
    IP20 IEC 60529 terminals)
    IP30 IEC 60529 casing)
    pollution degree
    3 IEC 60664-1
    dielectric test voltage
    2 kV AC 50 Hz
    non-dissipating shock wave
    4 kV
    Ordering and shipping details
    Category
    22380 - RELAYS-MEASUREMENT (RM17-RM35)
    Discount Schedule
    CP2
    GTIN
    00785901677567
    Returnability
    Yes
    Country of origin
    ID
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    California proposition 65
    WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages19
    • English18
    • French5
    • German4
    • Italian4
    • Spanish4
    Catalog
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 8.1 MB
    Date 6/24/19
    prp.document.label.format pdf
    Size 6 MB
    Date 5/12/19
    prp.document.label.format pdf
    Size 7.1 MB
    Date 6/24/19
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 3 MB
    Date 5/23/19
    UL Listed RM17, RM22, RM35, RM8487 (Version 1.0)
    Files in document
    pdf
    475.7 KB
    pdf
    473.4 KB
    prp.document.label.format zip
    Size 949 KB
    Date 5/19/15
    Files in document
    pdf
    475.7 KB
    pdf
    473.4 KB
    prp.document.label.format htm
    Size 213 B
    Date 5/18/15
    Instruction Sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 522.9 KB
    Date 4/1/19
    prp.document.label.format pdf
    Size 369.4 KB
    Date 1/1/08
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    RM35S0MW : RM35S0MW_ROHS_CHINA_DECLARATION
    Description
    RM35S0MW_ROHS_CHINA_DECLARATION
    prp.document.label.format pdf
    Size 195.3 KB
    Date 6/1/20
    Description
    RM35S0MW_ROHS_CHINA_DECLARATION
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 5.4 MB
    Date 5/1/19
    prp.document.label.format pdf
    Size 89.6 KB
    Date 2/1/16
    prp.document.label.format pdf
    Size 582.8 KB
    Date 11/1/11
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    RM35S0MW : RM35S0MW_ROHS_DECLARATION
    Description
    RM35S0MW_ROHS_DECLARATION
    prp.document.label.format pdf
    Size 195.3 KB
    Date 6/1/20
    Description
    RM35S0MW_ROHS_DECLARATION
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 5.4 MB
    Date 5/1/19
    prp.document.label.format pdf
    Size 3.3 MB
    Date 1/1/16
    prp.document.label.format pdf
    Size 2.2 MB
    Date 11/1/11
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    RM35S0MW : RM35S0MW_REACH_DECLARATION
    Description
    RM35S0MW_REACH_DECLARATION
    prp.document.label.format pdf
    Size 195.3 KB
    Date 6/1/20
    Description
    RM35S0MW_REACH_DECLARATION
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Speed Control Relays
    Dimensions and Mounting



  • Connections and Schema

    Speed Control Relays
    Wiring Diagrams

    Contact input


    (2)
    A quick-blow fuse or circuit-breaker.
    S2
    Inhibit - Reset

    Namur proximity sensor input


    (2)
    A quick-blow fuse or circuit-breaker.
    S2
    Inhibit - Reset

    NPN/PNP sensor input


    (2)
    A quick-blow fuse or circuit-breaker.
    S2
    Inhibit - Reset

    0-30 V voltage input


    (2)
    A quick-blow fuse or circuit-breaker.
    S2
    Inhibit - Reset


  • Technical Description

    Function Diagrams
    Underspeed Control

    Without memory ("No Memory" mode)


    With memory ("Memory" mode)


    With inhibition by S2 (“Inhib./S2” mode)


    Overspeed Control

    Without memory ("No Memory" mode)


    With memory ("Memory" mode)


    Legend

    Ti Starting inhibition time delay

    Un Supply voltage

    V Monitored speed

    H Hysteresis

    Vs Overspeed threshold

    S2 Inhibition external contact

    In LED indicating the inhibition status

    (1) Power break to reset the output relay

    (2) S2 contact closure to make the output relay return to normal state

    11-12/11-14 Output relay connections

    Relay status: black color = energized.

    NOTE: In "Memory" mode, the relay opens after the time delay and stays in that position when crossing of the threshold is detected. The power supply voltage must be switched off to reset the product.

    With inhibition by S2 (“Inhib./S2” mode)