USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Select your location
View all Zelio Control
Schneider Eletric RM4JA32F Picture
Discontinued

RM4JA32F

Schneider Eletric RM4JA32F Picture
Discontinued
RM4JA32F

current measurement relay RM4-J - range 0.3..15 A - 110..130 V AC

Show more characteristics
Commercial status
Discontinued on 31 December 2016
End-of-service on 31 December 2016
RM4JA32F  has not been replaced. Please contact your customer care center for more information.
  • Price*
    378.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Zelio Control
    product or component type
    Industrial measurement and control relays
    relay type
    Current measurement relay
    relay name
    RM4J
    relay monitored parameters
    Overcurrent or undercurrent detection
    time delay
    Adjustable 0.05...30 s
    maximum power consumption in VA
    3.3 VA AC
    measurement range
    1...5 A current AC
    1...5 A current DC
    3...15 A current AC
    3...15 A current DC
    300...1500 mA current AC
    300...1500 mA current DC
    contacts type and composition
    2 C/O
    Complementary
    maximum switching voltage
    440 V AC
    [Us] rated supply voltage
    110...130 V AC 50/60 Hz +/- 5 %
    operating voltage tolerance
    0.85...1.1 Uc
    output contacts
    2 C/O
    maximum measuring cycle
    80 ms
    internal input resistance
    0.02 Ohm
    0.06 Ohm
    0.006 Ohm
    permissible continuous overload
    2 A
    20 A
    7 A
    permissible non repetitive overload
    10 A <= 3 s
    100 A
    15 A
    setting accuracy of the switching threshold
    +/-5 %
    switching threshold drift
    <= 0.06 % per degree centigrade depending permissible ambient air temperature
    <= 0.5 % within the supply voltage range (0.85...1.1 Un)
    setting accuracy of time delay
    10 P
    time delay drift
    <= 0.07 % per degree centigrade depending on temperature
    <= 0.5 % within the supply voltage range (0.85...1.1 Un)
    hysteresis
    5…30 % adjustable current threshold setting
    marking
    CE : EMC 89/336/EEC
    CE : LVD 73/23/EEC
    overvoltage category
    III IEC 60664-1
    [Ui] rated insulation voltage
    500 V IEC
    supply disconnection value
    > 0.1 Uc
    operating position
    Any position without
    connections - terminals
    Screw terminals, 2 x 1.5 mm²flexible with cable end
    Screw terminals, 2 x 2.5 mm²flexible without cable end
    tightening torque
    5.31…9.74 lbf.in (0.6…1.1 N.m)
    mechanical durability
    30000000 cycles
    [Ith] conventional free air thermal current
    8 A
    [Ie] rated operational current
    2 A 24 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991
    2 A 24 V DC-13 158 °F (70 °C) VDE 0660
    3 A 115 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991
    3 A 115 V AC-15 158 °F (70 °C) VDE 0660
    3 A 24 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991
    3 A 24 V AC-15 158 °F (70 °C) VDE 0660
    3 A 250 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991
    3 A 250 V AC-15 158 °F (70 °C) VDE 0660
    0.1 A 250 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991
    0.1 A 250 V DC-13 158 °F (70 °C) VDE 0660
    0.3 A 115 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991
    0.3 A 115 V DC-13 158 °F (70 °C) VDE 0660
    switching capacity in mA
    10 mA 12 V
    switching voltage
    250 V AC
    contacts material
    90/10 silver nickel contacts
    number of cables
    2
    width
    1.77 in (45 mm)
    height
    3.07 in (78 mm)
    depth
    3.15 in (80 mm)
    terminals description ISO n°1
    (15-16-18)OC
    (C-B1-B2-B3)CO
    (A1-A2)CO
    (25-26-28)OC
    output relay state
    Tripped if A measured > A set
    Tripped if V measured > V set
    9 mm pitches
    5
    net weight
    0.45 lb(US) (0.204 kg)
    Environment
    electromagnetic compatibility
    Electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2
    Electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2
    standards
    EN/IEC 60255-6
    product certifications
    GL
    CSA
    UL
    ambient air temperature for storage
    -40…185 °F (-40…85 °C)
    ambient air temperature for operation
    -4…149 °F (-20…65 °C)
    environmental characteristic
    3K3
    relative humidity
    15…85 % IEC 60721-3-3
    shock resistance
    15 gn 11 ms IEC 60255-21-1
    IP degree of protection
    IP20 IEC 60529 terminals)
    IP50 IEC 60529 casing)
    pollution degree
    3 IEC 60664-1
    dielectric test voltage
    2.5 kV
    non-dissipating shock wave
    4.8 kV
    resistance to electrostatic discharge
    6 kV contact IEC 61000-4-2 level 3
    8 kV air IEC 61000-4-2 level 3
    resistance to electromagnetic fields
    9.14 V/m (10 V/m) IEC 61000-4-3 level 3
    resistance to fast transients
    2 kV IEC 61000-4-4 level 3
    protection against electric shocks
    2 kV level 3 IEC 61000-4-5
    disturbance radiated/conducted
    CISPR 22 - class A
    CISPR 11 group 1 - class A
    Ordering and shipping details
    Category
    22376-RELAYS-MEASUREMENT(RM4)
    Discount Schedule
    CP2
    GTIN
    00785901481560
    Package weight(Lbs)
    0.52 lb(US) (0.235 kg)
    Returnability
    No
    Country of origin
    ID
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages5
    • English5
    • French2
    • German2
    • Italian2
    • Portuguese2
    • Spanish2
    Instruction Sheet
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 1.3 MB
    Date 2/1/06
    Description
    None
    Size pdf
    Size 456.3 KB
    Date 11/1/04
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Current Measurement Relays
    Dimensions



  • Mounting and Clearance

    Current Measurement Relays
    Rail mounting


    Screw fixing



  • Connections and Schema

    Current Measurement Relays
    RM4JA01 Wiring Diagram


    A1-A2
    Supply voltage
    B1, B2, B3, C
    Currents to be measured (see table below)

    Connection and current values to be measured

    B1-C

    3…30 mA

    B2-C

    10…100 mA

    B3-C

    0.1…1 A

    RM4JA31 Wiring Diagram


    A1-A2
    Supply voltage
    B1, B2, B3, C
    Currents to be measured (see table below)

    Connection and current values to be measured

    B1-C

    3…30 mA

    B2-C

    10…100 mA

    B3-C

    0.1…1 A

    RM4JA32 Wiring Diagram


    A1-A2
    Supply voltage
    B1, B2, B3, C
    Currents to be measured (see table below)

    Connection and current values to be measured

    B1-C

    0.3…1.5 A

    B2-C

    1…5 A

    B3-C

    3…15 A


    Application Schemes
    Example: Detection of Blockage on a Crusher (Overcurrent Function)

    Current measured ≤15 A


    Current measured > 15 A



  • Performance Curves

    Electrical Durability and Load Limit Curves
    AC Load

    Curve 1: Electrical durability of contacts on resistive load in millions of operating cycles


    X
    Current broken in A
    Y
    Millions of operating cycles

    Curve 2: Reduction factor k for inductive loads (applies to values taken from durability Curve 1)


    X
    Power factor on breaking (cos φ)
    Y
    Reduction factor K

    DC Load

    Load limit curve


    X
    Current in A
    Y
    Voltage in V
    1
    L/R = 20 ms
    2
    L/R with load protection diode
    3
    Resistive load



  • Technical Description

    Function Diagram
    Overcurrent Detection

    Function “>”


    Legend

    t Time delay

    U A1-A2 Supply voltage

    IS1 Setting current threshold

    IS2 Current measured

    15-18, 15-16; 25-28, 25-26 Output relays connections

    Relay status: black color = energized.


    Function Diagram
    Undercurrent Detection

    Function “<”


    Legend

    t Time delay

    U A1-A2 Supply voltage

    IS1 Setting current threshold

    IS2 Current measured

    15-18, 15-16; 25-28, 25-26 Output relays connections

    Relay status: black color = energized.