-
Characteristics
Overview Model Name APC Smart-UPS RT 10,000VA RM 208VIncludes CD with software , Rack Mounting support rails , Smart UPS signalling RS-232 cable , User Manual , Web/SNMP Management CardStandard Lead Time Usually in StockProduct Distribution Anguilla , Antigua And Barbuda , Argentina , Aruba , Bahamas , Barbados , Belize , Bermuda , Bolivia , Brazil , Canada , Chile , Colombia , Costa Rica , Cuba , Dominica , Dominican Republic , Ecuador , El Salvador , Falkland Islands (Malvinas) , Grenada , Guadeloupe , Guatemala , Guyana , French Guiana , Haiti , Honduras , Jamaica , Madagascar , Martinique , Mauritius , Mayotte , Mexico , Netherlands Antilles , Nicaragua , Panama , Paraguay , Peru , Puerto Rico , Reunion , SAINT KITTS AND NEVIS , SAINT LUCIA , SAINT VINCENT AND THE GRENADINES , Trinidad And Tobago , Turks And Caicos Islands , United States , Uruguay , Venezuela , VIRGIN ISLANDS (UNITED STATES)Output Output Power Capacity 8000 Watts / 10.0 kVAMax Configurable Power (Watts) 8000 Watts / 10.0 kVANominal Output Voltage 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageOutput Voltage Distortion Less than 3%Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1Other Output Voltages 240VCrest Factor 3 : 1Double Conversion OnlineWaveform Type Sine waveOutput Connections (1) Hard Wire 3-wire (2PH + G) (Battery Backup) , (2) NEMA L6-20R (Battery Backup) , (2) NEMA L6-30R (Battery Backup)Bypass Internal Bypass (Automatic and Manual)Input Nominal Input Voltage 208VInput Frequency 50/60 Hz +/- 5 Hz (auto sensing)Input Connections Hard Wire 3-wire (2PH + G)Input voltage range for main operations 160 - 280 VOther Input Voltages 240Batteries & Runtime Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproofIncluded Battery Modules 4Typical recharge time 2.2 hour(s)Replacement Battery RBC44RBC Quantity 2Communications & Management Interface Port(s) DB-9 RS-232 , RJ-45 10/100 Base-T , Smart-SlotPre-Installed SmartSlot™ Cards AP9619Control panel LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass IndicatorsAudible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarmEmergency Power Off (EPO) YesSurge Protection and Filtering Filtering Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449Physical Maximum Height 10.35 inches (263.0 mm)Maximum Width 17.0 inches (432.0 mm)Maximum Depth 28.98 inches (736.0 mm)Rack Height 6 UNet Weight 244.0 lbs (110.91 kg)Shipping Weight 284.0 lbs (129.09 kg)Shipping Height 21.75 inches (552.0 mm)Shipping Width 23.5 inches (597.0 mm)Shipping Depth 39.0 inches (991.0 mm)Color BlackUnits per Pallet 1.0Environmental Operating Environment 32 - 104 °F (0 - 40 °C)Operating Relative Humidity 0 - 95 %Operating Elevation 0-10000 feet (0-3000 meters)Storage Temperature 5 - 113 °F (-15 - 45 °C)Storage Relative Humidity 0 - 95 %Storage Elevation 0-50000 feet (0-15000 meters)Audible noise at 1 meter from surface of unit 55.000 dBOnline Thermal Dissipation 2216.000 BTU/hrConformance Approvals CSA , FCC Part 15 Class A , UL 1778Standard warranty 2 years repair or replace -
View more
Documents
Language- All Languages6
- English3
- French1
- Spanish2
User guideFormatSizeAdd to My DocumentsSURT 8000/10000 VA Tower/Rack-Mount 6U 200-240 Vac (Version 8)DescriptionUser manual for SURT 8000/10000 VA Tower/Rack-Mount 6U 200-240 VacSize pdfSize 657.6 KBDate 1/6/16DescriptionUser manual for SURT 8000/10000 VA Tower/Rack-Mount 6U 200-240 VacSURT 8000/10000 VA à montage en tour/rack 6U 200-240 VCA (Version 8)DescriptionManuel dutilisation de londuleur Smart-UPS SURT 8000/10000 VA en tour/rack 6U 200-240 VCASize pdfSize 1.1 MBDate 1/6/16DescriptionManuel dutilisation de londuleur Smart-UPS SURT 8000/10000 VA en tour/rack 6U 200-240 VCAGuía de seguridad de Smart-UPS RT/cableados/superiores a 1,5 kVA (Version 1.1)DescriptionGuía de seguridad de Smart-UPS RT/cableados/superiores a 1,5 kVASize pdfSize 126 KBDate 2/1/17DescriptionGuía de seguridad de Smart-UPS RT/cableados/superiores a 1,5 kVASURT de 8000/10 000 VA, montaje en torre/rack 6U y 200-240 V AC (Version 8)DescriptionManual del usuario para SURT de 8000/10 000 VA, montaje en torre/rack 6U y 200-240 V ACSize pdfSize 1.1 MBDate 1/6/16DescriptionManual del usuario para SURT de 8000/10 000 VA, montaje en torre/rack 6U y 200-240 V ACCADFormatSizeAdd to My DocumentsSBP16KP - Service Bypass Panel 200/208/240V; 100A; MBB; Hardwire input/output (Version 0)Files in documentDescriptionService Bypass PanelSize zipSize 774.7 KBDate 8/16/12Files in documentDescriptionService Bypass PanelCertificateFormatSizeAdd to My DocumentsUL Listed (Version 0)DescriptionUL Listed and complies to UL 1778Size zipSize 13.2 KBDate 7/26/04DescriptionUL Listed and complies to UL 1778 -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.