USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Select your location
View all Twido - Programmable Controller
Schneider Eletric TWDLCAA24DRF Picture

TWDLCAA24DRF

Schneider Eletric TWDLCAA24DRF Picture
TWDLCAA24DRF

extendable PLC base Twido - 100..240 V AC supply - 14 I 24 V DC - 10 O relay

Show more characteristics
Commercial status
Discontinued on 31 December 2016
End-of-service on 31 December 2018
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
  • Price*
    536.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Twido
    product or component type
    Compact base controller
    discrete I/O number
    24
    discrete input number
    14
    discrete input voltage
    24 V
    discrete input voltage type
    DC
    discrete output number
    10 relay
    [Us] rated supply voltage
    100...240 V AC
    maximum number of I/O expansion module
    4
    use of slot
    Memory cartridge or realtime clock cartridge
    data backed up
    Internal RAM lithium, 30 days 10 h 10 year(s)
    integrated connection type
    Power supply
    Non isolated serial link mini DIN, Modbus/character mode master/slave RTU/ASCII RS485) half duplex, 38.4 kbit/s
    Serial link interface adaptor RS232C/RS485)
    complementary function
    Event processing
    PID
    Complementary
    discrete input logic
    Sink or source
    input voltage limits
    20.4...28.8 V
    discrete input current
    11 mA I0.0 to I0.1
    7 mA I0.2 to I0.13
    input impedance
    2100 Ohm I0.0 to I0.1
    3400 Ohm I0.2 to I0.13
    filter time
    150 µs + programmed filter time for I0.6 to I0.13 at state 0
    35 µs + programmed filter time for I0.0 to I0.5 at state 1
    40 µs + programmed filter time for I0.6 to I0.13 at state 1
    45 µs + programmed filter time for I0.0 to I0.5 at state 0
    insulation between channel and internal logic
    1500 Vrms for 1 minute
    insulation resistance between channel
    None
    minimum load
    0.1 mA
    contact resistance
    30000 µOhm
    load current
    2 A 240 V AC inductive 30 cyc/mn relay output
    2 A 240 V AC resistive 30 cyc/mn relay output
    2 A 30 V DC inductive 30 cyc/mn relay output
    2 A 30 V DC resistive 30 cyc/mn relay output
    mechanical durability
    20000000 cycles relay output
    electrical durability
    100000 cycles relay output
    current consumption
    36 mA 5 V DC at state 1
    5 mA 5 V DC at state 0
    55 mA 24 V DC at state 1
    I/O connection
    Non-removable screw terminal block
    maximum input/output number
    120 spring terminal block with I/O expansion module
    152 HE-10 connector with I/O expansion module
    88 removable screw terminal block with I/O expansion module
    network frequency
    50/60 Hz
    supply voltage limits
    85…264 V
    network frequency limits
    47…63 Hz
    power supply output current
    0.25 A 24 V DC sensors
    input current
    450 mA
    inrush current
    40 A
    protection type
    Power protection internal fuse
    power consumption in VA
    33 VA 100 V
    40 VA 264 V
    insulation resistance
    > 10 MOhm at 500 V, between I/O and earth terminals
    > 10 MOhm at 500 V, between supply and earth terminals
    program memory
    3000 instructions
    exact time for 1 Kinstruction
    1 ms
    system overhead
    0.5 ms
    memory description
    Internal RAM, 128 counters, no floating, no trigonometrical
    Internal RAM, 128 timers, no floating, no trigonometrical
    Internal RAM, 256 internal bits, no floating, no trigonometrical
    Internal RAM, 3000 internal words, no floating, no trigonometrical
    Internal RAM, double words, no floating, no trigonometrical
    free slots
    1
    realtime clock
    Without
    counting input number
    1 20000 Hz 32 bits
    3 5000 Hz 16 bits
    analogue adjustment points
    1 point adjustable from 0 to 511 points
    1 point adjustable from 0...1023
    status LED
    PWR 1 LED green)
    RUN 1 LED green)
    I/O status 1 LED per channel green)
    Module error (ERR) 1 LED red)
    User pilot light (STAT) 1 LED
    depth
    2.76 in (70 mm)
    height
    3.74 in (95 mm)
    width
    3.54 in (90 mm)
    terminals description PLC n°1
    (6)IN_DIS#6
    COM_NEG#0-13
    (-)PW_OUT_NEG
    (4)IN_DIS#4
    ALT
    (0)IN_DIS#0
    (13)IN_DIS#13
    (5)IN_DIS#5
    (8)IN_DIS#8
    (10)IN_DIS#10
    (11)IN_DIS#11
    TB_TOP
    (+)PW_OUT_POS
    (9)IN_DIS#9
    (3)IN_DIS#3
    (7)IN_DIS#7
    (12)IN_DIS#12
    (1)IN_DIS#1
    (2)IN_DIS#2
    terminals description PLC n°2
    (11)IN_DIS#10
    (9)IN_DIS#9
    (2)IN_DIS#2
    (1)IN_DIS#1
    (7)IN_DIS#7
    (3)IN_DIS#3
    (8)IN_DIS#8
    (+)PW_OUT_POS
    ALT_1
    COM_POS#0-13
    (12)IN_DIS#12
    (-)PW_OUT_NEG
    (4)IN_DIS#4
    (13)IN_DIS#13
    TB_TOP
    (6)IN_DIS#6
    (10)IN_DIS#10
    (0)IN_DIS#0
    (5)IN_DIS#5
    terminals description PLC n°3
    (COM0)COM#0-3
    (9)OUT_DIS#9
    (7)OUT_DIS#7
    (3)OUT_DIS#3
    (1)OUT_DIS#1
    (GND)GROUND
    (6)OUT_DIS#6
    (-)PW_NEG
    (COM2)COM#8
    TB_BOTTOM
    (COM1)COM#4-7
    (8)OUT_DIS#8
    (COM3)COM#9
    (5)OUT_DIS#5
    (4)OUT_DIS#4
    (2)OUT_DIS#2
    (0)OUT_DIS#0
    (+)PW_POS
    net weight
    0.67 lb(US) (0.305 kg)
    Environment
    immunity to microbreaks
    10 ms
    dielectric strength
    1500 V for 1 minute, between I/O and earth terminals
    1500 V for 1 minute, between supply and earth terminals
    product certifications
    UL
    CSA
    marking
    CE
    ambient air temperature for operation
    32…131 °F (0…55 °C)
    ambient air temperature for storage
    -13…158 °F (-25…70 °C)
    relative humidity
    30…95 % without condensation
    IP degree of protection
    IP20
    operating altitude
    0...6561.68 ft (0...2000 m)
    storage altitude
    0.00…9842.52 ft (0…3000 m)
    vibration resistance
    0.075 mm 10…57 Hz 35 mm symmetrical DIN rail
    1 gn 57…150 Hz 35 mm symmetrical DIN rail
    1.6 mm 2…25 Hz plate or panel with fixing kit
    4 gn 25…100 Hz plate or panel with fixing kit
    shock resistance
    15 gn 11 ms
    Ordering and shipping details
    Category
    22531 - PLCS, TWIDO, TWD
    Discount Schedule
    PC12
    GTIN
    00785901292470
    Package weight(Lbs)
    0.44 kg (0.96 lb(US))
    Returnability
    No
    Country of origin
    TW
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages36
    • English20
    • Chinese7
    • French18
    • German8
    • Italian8
    • Spanish17
    User guide
    Format
    Size
    Date
    Add to My Documents
    TwidoSuite V2.3 - Programming guide (Version 05)
    Description
    This is the Software Reference manual for Twido programmable controllers and consists of the following major parts: - Description of the Twido programming software and an introduction to the fundamentals needed to program Twido controllers. - Description of communications, managing analog I/O, installing the AS-Interface bus interface module, the CANopen fieldbus master module and other special functions. - Description of the software languages used to create Twido programs. - Description of instructions and functions of Twido controllers.
    Size pdf
    Size 7.4 MB
    Date 6/1/11
    Description
    This is the Software Reference manual for Twido programmable controllers and consists of the following major parts: - Description of the Twido programming software and an introduction to the fundamentals needed to program Twido controllers. - Description of communications, managing analog I/O, installing the AS-Interface bus interface module, the CANopen fieldbus master module and other special functions. - Description of the software languages used to create Twido programs. - Description of instructions and functions of Twido controllers.
    TwidoSuite V2.3, programming software - Getting started (Version 06)
    Description
    This document provides basic information and instructions for getting the TwidoSuite programming software set up and operating.
    Size pdf
    Size 1.7 MB
    Date 6/1/11
    Description
    This document provides basic information and instructions for getting the TwidoSuite programming software set up and operating.
    Twido Hardware Guide, Modular and Compact Bases (Version 05)
    Description
    This is the Hardware Guide for Twido programmable controllers for compact|modular bases.
    Size pdf
    Size 2.6 MB
    Date 6/1/11
    Description
    This is the Hardware Guide for Twido programmable controllers for compact|modular bases.
    Size pdf
    Size 2.9 MB
    Date 7/1/07
    Description
    None
    Size pdf
    Size 231.5 KB
    Date 3/1/05
    Description
    None
    Size pdf
    Size 8.8 MB
    Date 3/1/05
    Description
    None
    Size pdf
    Size 6 MB
    Date 3/1/05
    Description
    None
    Size pdf
    Size 5.1 MB
    Date 3/1/05
    Description
    None
    TwidoSuite V2.3 - Guide de programmation (Version 05)
    Description
    Le manuel de référence du logiciel des automates programmables Twido est composé des sections suivantes :- Description du logiciel de programmation Twido et introduction aux notions fondamentales requises pour programmer les automates Twido.- Description des communications, de la gestion des E/S analogiques, de l’installation du module d’interface de bus AS-Interface et du module maître de bus de terrain CANopen, et d’autres fonctions spéciales.- Description des langages logiciels utilisés pour créer des programmes Twido.- Description des instructions et des fonctions des automates Twido.
    Size pdf
    Size 5.9 MB
    Date 5/31/11
    Description
    Le manuel de référence du logiciel des automates programmables Twido est composé des sections suivantes :- Description du logiciel de programmation Twido et introduction aux notions fondamentales requises pour programmer les automates Twido.- Description des communications, de la gestion des E/S analogiques, de l’installation du module d’interface de bus AS-Interface et du module maître de bus de terrain CANopen, et d’autres fonctions spéciales.- Description des langages logiciels utilisés pour créer des programmes Twido.- Description des instructions et des fonctions des automates Twido.
    TwidoSuite V2.3, logiciel de programmation - Mise en route (Version 06)
    Description
    Ce document fournit des informations et des instructions caractéristiques sur la configuration et le fonctionnement du logiciel de programmation TwidoSuite.
    Size pdf
    Size 1.8 MB
    Date 5/31/11
    Description
    Ce document fournit des informations et des instructions caractéristiques sur la configuration et le fonctionnement du logiciel de programmation TwidoSuite.
    Twido Guide matériel, bases compactes et modulaires (Version 05)
    Description
    Ce document constitue le guide de référence du matériel des automates programmables Twido compacts et modulaires.
    Size pdf
    Size 2.7 MB
    Date 5/31/11
    Description
    Ce document constitue le guide de référence du matériel des automates programmables Twido compacts et modulaires.
    Size pdf
    Size 3 MB
    Date 7/1/07
    Size pdf
    Size 234.6 KB
    Date 2/28/05
    Size pdf
    Size 6.1 MB
    Date 2/28/05
    Size pdf
    Size 5.3 MB
    Date 2/28/05
    Size pdf
    Size 8.9 MB
    Date 2/28/05
    Twido Guía de hardware, Bases compactas y modulares (Version 05)
    Description
    Ésta es la Guía de hardware de los autómatas programables Twido para bases modulares y compactas.
    Size pdf
    Size 2.7 MB
    Date 5/31/11
    Description
    Ésta es la Guía de hardware de los autómatas programables Twido para bases modulares y compactas.
    TwidoSuite V2.3, software de programación - Guía rápida (Version 06)
    Description
    Ce document fournit des informations et des instructions caractéristiques sur la configuration et le fonctionnement du logiciel de programmation TwidoSuite.
    Size pdf
    Size 1.7 MB
    Date 5/31/11
    Description
    Ce document fournit des informations et des instructions caractéristiques sur la configuration et le fonctionnement du logiciel de programmation TwidoSuite.
    TwidoSuite V2.3 - Guía de programación (Version 05)
    Description
    Éste es el manual de referencia del software de los autómatas programables Twido. Está compuesto por las siguientes partes:- Descripción del software de programación Twido e introducción a los fundamentos necesarios para programar autómatas Twido.- Descripción de las comunicaciones, la gestión de las E/S analógicas, la instalación del módulo de interfaz del bus AS-Interface, el módulo Fieldbus Master CANopen y otras funciones especiales.- Descripción de los lenguajes de software utilizados para crear programas Twido.- Descripción de las instrucciones y de las funciones de los autómatas Twido.
    Size pdf
    Size 7.1 MB
    Date 5/31/11
    Description
    Éste es el manual de referencia del software de los autómatas programables Twido. Está compuesto por las siguientes partes:- Descripción del software de programación Twido e introducción a los fundamentos necesarios para programar autómatas Twido.- Descripción de las comunicaciones, la gestión de las E/S analógicas, la instalación del módulo de interfaz del bus AS-Interface, el módulo Fieldbus Master CANopen y otras funciones especiales.- Descripción de los lenguajes de software utilizados para crear programas Twido.- Descripción de las instrucciones y de las funciones de los autómatas Twido.
    Size pdf
    Size 4.4 MB
    Date 7/1/07
    Size pdf
    Size 6.1 MB
    Date 3/1/05
    Size pdf
    Size 5.3 MB
    Date 2/28/05
    Size pdf
    Size 8.9 MB
    Date 2/28/05
    Size pdf
    Size 235.5 KB
    Date 2/28/05
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD file (on TraceParts) for TWDLCAA24DRF: extendable PLC base Twido - 100..240 V AC supply - 14 I 24 V DC - 10 O relay (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for TWDLCAA24DRF: extendable PLC base Twido - 100..240 V AC supply - 14 I 24 V DC - 10 O relay (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    Size zip
    Size 1.9 MB
    Date 10/25/10
    Files in document
    Instruction Sheet
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 1 MB
    Date 4/1/13
    Size pdf
    Size 84 KB
    Date 9/1/06
    Size pdf
    Size 1.1 MB
    Date 10/1/04
    Description
    None
    Size pdf
    Size 230.3 KB
    Date 4/1/04
    Description
    None
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    Marine certificate
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 150.6 KB
    Date 5/19/16
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /