Nous utilisons les entrèes logiques de telle manière: LI1 = AV LI2 = AR LI3 = + vite LI4 = - vite LI5 = LAB LI6 = JOG ou SP1 L'application est ...

Goals and Symptoms

Nous utilisons les entrèes logiques de telle manière:
LI1 = AV
LI2 = AR
LI3 = + vite
LI4 = - vite
LI5 = LAB
LI6 = JOG ou SP1
L'application est un enrouleur de bobine de câble simple.
Le client appuit sur l'ordre de marche AV ou AR et fait du + ou - vite pour réglage vitesse.
Un compteur est actionné suivant la longueur programmée, et envoi l'information de passage en PV 1 m avant. Ce passage devient le Jog et nous devons actionner le LAB car changement de type de consigne. Cela n'est réalisable que par le passage de LI1 ou 2 par zéro. Le client veut passer en PV avec le JOG sans avoir à actionner le LAB et arrêt machine. En résumé passage d'une vitesse +/- vite en PV programmé sans passage à zéro.

Causes and Fixes

Il suffit d'appliquer l'équivalent de la valeur du JOG sur AI1 et lorsque tu vas basculer de FR2 à FR1 c'est AI1
qui sera pris en compte, pas besoin de passage par 0 sur LI1 ou LI2 ( et tu gagnes une LI ).