Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   Zelio Control
RMNF22TB30 Product picture Schneider Electric

RMNF22TB30

Green premium brand logo
RMNF22TB30 Product picture Schneider Electric
RMNF22TB30
Green premium brand logo

NFC 3-phase monitoring relay, 8 A, 2CO, multifunction, 208…480 V AC

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    Zelio Control
    product or component type
    3-phase control relay
    relay type
    Control relay
    network number of phases
    3 phases
    relay name
    RMNF22
    relay monitored parameters
    Phase sequence
    Phase failure detection
    Overvoltage detection
    Undervoltage detection
    Overfrequency and underfrequency
    Asymmetry
    Supported OS
    Android
    software version
    V4.4 and above
    App for product
    Zelio NFC (downloadable from Google Play store)
    product compatibility
    NFC enabled mobile device
    time delay type
    On-delay 0.1 s...60 min
    Off-delay 0.1 s...60 min
    switching capacity in VA
    2000 VA
    Complementary
    NFC operating frequency
    13.56 MHz
    Maximum RF power transmitted
    0.0002 mW
    reset time
    1500 ms at maximum voltage
    maximum switching voltage
    250 V AC
    minimum switching current
    100 mA at 6 V
    maximum switching current
    8 A AC
    [Us] rated supply voltage
    208...480 V AC line to line
    120...277 V AC line to neutral
    supply voltage limits
    166.4…576 V AC line to line
    96…332.4 V AC line to neutral
    power consumption in VA
    4 VA at 480 V AC 60 Hz
    on-load factor
    100 %
    supply voltage frequency
    50...60 Hz +/- 10 %
    output contacts
    2 C/O
    setting accuracy of the switching threshold
    +/- (1.5 % + 1 V)
    setting accuracy of time delay
    +/- 3 % for 10 s...60 min time delay range
    +/- 300 ms for 0...10 s time delay range
    hysteresis
    3 % of fixed for phase failure detection
    alarm threshold
    166...576 V adjustable overvoltage and undervoltage detection (line to line)
    96...332 V adjustable overvoltage and undervoltage detection (line to neutral)
    5...150 V adjustable asymmetry
    45...66 Hz adjustable overfrequency or underfrequency