View all
Sepam series 40
-
Characteristics
Main range of product Sepam series 20Sepam series 40Sepam series 60Sepam series 80device short name DSM303user machine interface type Remote advancedComplementary UMI indication Sepam parameter settingVersion of Sepam and remote modulesMetering and diagnosis dataProtection settingAlarms and operating messagesStatus of logic imputsUMI control Alarm acknowledgementOutput testingSepam resetlocal signalling 2 LEDs for Sepam operating status (front face)9 LEDs for indication of parameters (front face)height 117 mmwidth 152 mmdepth 40 mmnet weight 0.3 kgmechanical robustness Earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3Earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3Jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2Shocks de-energized (level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2Shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2Vibrations de-energized (level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1Vibrations in operation (level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1Vibrations in operation (level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6Environment IP degree of protection IP52 conforming to IEC 60529electromagnetic compatibility Fast transient bursts: (immunity tests-conducted disturbances), A and B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4Fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4Immunity to conducted RF disturbances: (immunity tests-conducted disturbances), III, 10 V, conforming to IEC 60255-22-6Immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (1-3 s), conforming to IEC 61000-4-8Immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz...2 GHz, conforming to IEC 61000-4-3Surges: (immunity tests-conducted disturbances), III, 2 kV CM, 1 kV DM, conforming to IEC 61000-4-51 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 60255-22-11 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 2.5 kV DM, conforming to ANSI C37.90.1100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 61000-4-12Conducted disturbance emission: (emission tests), conforming to IEC 60255-25Conducted disturbance emission: (emission tests), A, conforming to EN 55022Disturbing field emission: (emission tests), conforming to IEC 60255-25Disturbing field emission: (emission tests), A, conforming to EN 55022Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2Fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1Immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz...1 GHz, conforming to IEC 60255-22-3Immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz...1 GHz, conforming to ANSI C37.90.2Voltage interruptions: (immunity tests-conducted disturbances), 100 % during 100 ms, conforming to IEC 60255-11climatic withstand Continuous exposure to damp heat (in operation) : Cab: 10 days, 93 % RH, 40 °C conforming to IEC 60068-2-78Continuous exposure to damp heat (in storage) : Cab: 56 days, 93 % RH, 40 °C conforming to IEC 60068-2-78Continuous exposure to damp heat (in storage) : Db: 6 days, 95 % RH, 55 °C conforming to IEC 60068-2-30Exposure to cold (in storage) : Ab: - 25 °C conforming to IEC 60068-2-1Exposure to dry heat (in operation) : Bd: 70 °C conforming to IEC 60068-2-2Exposure to dry heat (in storage) : Bb: 70 °C conforming to IEC 60068-2-2Salt mist (in operation) : Kb/2: 6 days conforming to IEC 60068-2-52Temperature variation with specified variation rate (in storage) : Nb: - 25 °C to 70 °C, 5 °C/min conforming to IEC 60068-2-14Influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60Exposure to cold: Ad: - 25 °C conforming to IEC 60068-2-1Offer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your informationEnvironmental Disclosure Circularity Profile -
View more
Documents
Language- All Languages8
- English6
- French2
CatalogueFormatSizeAdd to My DocumentsCatalogue Sepam serie 20, 40, 60, 80 - Cover (Version 6.0)DescriptionEdition 2018Size pdfSize 31 MBDate 3/4/18DescriptionEdition 2018User guideFormatSizeAdd to My DocumentsSepam series 20, user's manual (Version 9)DescriptionUser's manual of the Sepam series 20 protection relaysSize pdfSize 8.6 MBDate 2/1/17DescriptionUser's manual of the Sepam series 20 protection relaysSepam série 80, manuel d'exploitation (Version 10)DescriptionManuel d'exploitation des relais de protection Sepam série 80Size pdfSize 11.4 MBDate 9/1/17DescriptionManuel d'exploitation des relais de protection Sepam série 80Sepam série 20, manuel d'utilisation (Version 9)DescriptionManuel d'utilisation des relais de protection Sepam série 20Size pdfSize 10.7 MBDate 2/1/17DescriptionManuel d'utilisation des relais de protection Sepam série 20China RoHS declarationFormatSizeAdd to My Documentsremote advanced UMI module DSM303 Sepam series 20, 40, 60, 80Descriptionremote advanced UMI module DSM303 Sepam series 20, 40, 60, 80Size pdfSize 195.3 KBDate 12/16/19Descriptionremote advanced UMI module DSM303 Sepam series 20, 40, 60, 80EU RoHS DeclarationFormatSizeAdd to My Documentsremote advanced UMI module DSM303 Sepam series 20, 40, 60, 80Descriptionremote advanced UMI module DSM303 Sepam series 20, 40, 60, 80Size pdfSize 195.3 KBDate 12/16/19Descriptionremote advanced UMI module DSM303 Sepam series 20, 40, 60, 80Product Environmental ProfileFormatSizeAdd to My DocumentsPEP Sepam series 80 [2003-2004 format] (Version 1.0)DescriptionNoneSize pdfSize 96.7 KBDate 10/7/05DescriptionNoneREACh DeclarationFormatSizeAdd to My Documentsremote advanced UMI module DSM303 Sepam series 20, 40, 60, 80Descriptionremote advanced UMI module DSM303 Sepam series 20, 40, 60, 80Size pdfSize 195.3 KBDate 12/16/19Descriptionremote advanced UMI module DSM303 Sepam series 20, 40, 60, 80 -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.