Welcome to the Schneider Electric corporate Website

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   Sepam Series 80 NPP
Schneider Electric 59643 Image

59643

Schneider Electric 59643 Image
59643

RS485 interface 4 wires ACE959 for Sepam 20, 40, 60, 80

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    Sepam series 20
    Sepam series 40
    Sepam series 48
    Sepam series 80 NPP
    Sepam series 80
    Sepam series 60
    device short name
    ACE959
    Complementary
    communication port protocol
    Modbus RTU network: E-LAN interface: RS485 - 4-wire
    Modbus RTU network: S-LAN interface: RS485 - 4-wire
    local signalling
    LED for link activity (front face)
    [Us] rated supply voltage
    12 V DC tolerance: +/- 10 %
    24 V DC tolerance: +/- 10 %
    maximum supply current
    16 mA: receiving mode
    40 mA: maximum in sending mode
    mounting mode
    Fixed
    mounting support
    Symmetrical DIN rail
    height
    88 mm
    width
    144 mm
    depth
    30 mm
    net weight
    0.2 kg
    mechanical robustness
    Earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3
    Earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3
    Jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2
    Shocks de-energized (level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2
    Shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2
    Vibrations de-energized (level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
    Vibrations in operation (level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
    Vibrations in operation (level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6
    maximum cable distance between devices
    10 Devices <180 m at 12 V DC
    10 Devices <750 m at 24 V DC
    20 Devices <160 m at 12 V DC
    20 Devices <450 m at 24 V DC
    25 Devices <125 m at 12 V DC
    25 Devices <375 m at 24 V DC
    5 Devices <1000 m at 24 V DC
    5 Devices <320 m at 12 V DC
    auxiliary connection terminal
    Earthing terminal: screw-type connectorcable 2.5…50 mm² <0.2 m
    Earthing terminal: screw-type connectortinned copper braid 6…100 mm²
    tightening torque
    Earthing terminal: 2.2 N.m
    Environment
    electromagnetic compatibility
    1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 60255-22-1
    1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 2.5 kV DM, conforming to ANSI C37.90.1
    100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 61000-4-12
    Conducted disturbance emission: (emission tests), conforming to IEC 60255-25
    Conducted disturbance emission: (emission tests), A, conforming to EN 55022
    Disturbing field emission: (emission tests), conforming to IEC 60255-25
    Disturbing field emission: (emission tests), A, conforming to EN 55022
    Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3
    Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2
    Fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1
    Fast transient bursts: (immunity tests-conducted disturbances), A and B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4
    Fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4
    Immunity to conducted RF disturbances: (immunity tests-conducted disturbances), III, 10 V, conforming to IEC 60255-22-6
    Immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (1-3 s), conforming to IEC 61000-4-8
    Immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz...1 GHz, conforming to IEC 60255-22-3
    Immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz...1 GHz, conforming to ANSI C37.90.2
    Immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz...2 GHz, conforming to IEC 61000-4-3
    Surges: (immunity tests-conducted disturbances), III, 2 kV CM, 1 kV DM, conforming to IEC 61000-4-5
    Voltage interruptions: (immunity tests-conducted disturbances), 100 % during 100 ms, conforming to IEC 60255-11
    climatic withstand
    Influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60
    Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60
    Continuous exposure to damp heat (in operation) : Cab: 10 days, 93 % RH, 40 °C conforming to IEC 60068-2-78
    Continuous exposure to damp heat (in storage) : Cab: 56 days, 93 % RH, 40 °C conforming to IEC 60068-2-78
    Continuous exposure to damp heat (in storage) : Db: 6 days, 95 % RH, 55 °C conforming to IEC 60068-2-30
    Exposure to cold (in operation) : Ad: - 25 °C conforming to IEC 60068-2-1
    Exposure to cold (in storage) : Ab: - 25 °C conforming to IEC 60068-2-1
    Exposure to dry heat (in operation) : Bd: 70 °C conforming to IEC 60068-2-2
    Exposure to dry heat (in storage) : Bb: 70 °C conforming to IEC 60068-2-2
    Salt mist (in operation) : Kb/2: 6 days conforming to IEC 60068-2-52
    Temperature variation with specified variation rate (in storage) : Nb: - 25 °C to 70 °C, 5 °C/min conforming to IEC 60068-2-14
    ambient air temperature for operation
    -25…70 °C
    Packing Units
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    203 g
    Package 1 Height
    6.5 cm
    Package 1 width
    12.5 cm
    Package 1 Length
    18.3 cm
    Unit Type of Package 2
    S02
    Number of Units in Package 2
    8
    Package 2 Weight
    1.91 kg
    Package 2 Height
    15 cm
    Package 2 width
    30 cm
    Package 2 Length
    40 cm
    Offer Sustainability
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    Circularity Profile
  • View more View less

    Documents

    Language
    • All Languages12
    • English9
    • French7
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 31 MB
    Date 3/4/18
    Description
    Edition 2018
    User guide
    Format
    Size
    Date
    Add to My Documents
    Sepam series 20, user's manual (Version 9)
    Description
    User's manual of the Sepam series 20 protection relays
    prp.document.label.format pdf
    Size 8.6 MB
    Date 2/1/17
    Description
    User's manual of the Sepam series 20 protection relays
    prp.document.label.format pdf
    Size 11.4 MB
    Date 9/1/17
    prp.document.label.format pdf
    Size 10.7 MB
    Date 2/1/17
    prp.document.label.format pdf
    Size 10.4 MB
    Date 6/30/10
    CAD
    Format
    Size
    Date
    Add to My Documents
    ACE959 (Version 1.0)
    Files in document
    dwg
    38.4 KB
    dxf
    45.6 KB
    dwf
    2.6 KB
    wmf
    5 KB
    prp.document.label.format zip
    Size 91.5 KB
    Date 1/13/05
    Files in document
    dwg
    38.4 KB
    dxf
    45.6 KB
    dwf
    2.6 KB
    wmf
    5 KB
    ACE959 (Version 1.0)
    Files in document
    dwg
    36 KB
    dxf
    39.4 KB
    dwf
    2.1 KB
    wmf
    3.9 KB
    prp.document.label.format zip
    Size 81.4 KB
    Date 1/13/05
    Files in document
    dwg
    36 KB
    dxf
    39.4 KB
    dwf
    2.1 KB
    wmf
    3.9 KB
    Connecting ACE959 (Version 1.0)
    Files in document
    dwg
    32.7 KB
    dxf
    29.8 KB
    dwf
    1.8 KB
    wmf
    5 KB
    prp.document.label.format zip
    Size 69.3 KB
    Date 1/13/05
    Files in document
    dwg
    32.7 KB
    dxf
    29.8 KB
    dwf
    1.8 KB
    wmf
    5 KB
    ACE959 (Version 1.0)
    Files in document
    dwg
    43.7 KB
    dxf
    59.9 KB
    dwf
    3.3 KB
    wmf
    8.2 KB
    prp.document.label.format zip
    Size 115 KB
    Date 1/13/05
    Files in document
    dwg
    43.7 KB
    dxf
    59.9 KB
    dwf
    3.3 KB
    wmf
    8.2 KB
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    59643 : RS485 interface 4 wires ACE959 for Sepam 20, 40, 60, 80
    Description
    RS485 interface 4 wires ACE959 for Sepam 20, 40, 60, 80
    prp.document.label.format pdf
    Size 195.3 KB
    Date 8/14/20
    Description
    RS485 interface 4 wires ACE959 for Sepam 20, 40, 60, 80
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    59643 : RS485 interface 4 wires ACE959 for Sepam 20, 40, 60, 80
    Description
    RS485 interface 4 wires ACE959 for Sepam 20, 40, 60, 80
    prp.document.label.format pdf
    Size 195.3 KB
    Date 8/14/20
    Description
    RS485 interface 4 wires ACE959 for Sepam 20, 40, 60, 80
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 96.7 KB
    Date 10/7/05
    Description
    None
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.