View all
Acti9 iDPN N Arc

A9FDB625
A9FDB625
Acti 9 - iDPN N Arc - 1P+N 25A C 6000A - Arc fault detection circuit breaker
Show more characteristics-
Characteristics
Main range Acti 9product name Acti 9 iDPN N Arcproduct or component type Arc fault detection circuit breakerproduct specific application Fire prevention by arc detectionstandards EN/IEC 62606IEC 60898-1device short name IDPN N Arcpoles description 1P + N[In] rated current 25 A at 30 °Ccurve code Cbreaking capacity 6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898network type ACneutral position Lefttrip unit technology Thermal-magneticComplementary network frequency 50 Hz[Ue] rated operational voltage 230 V AC 50 Hz conforming to IEC 62606230 V AC 50 Hz conforming to EN/IEC 60898-1device location in system Outgoermagnetic tripping limit 5...10 x Inlimitation class 3 conforming to IEC 60898-1threshold tripping voltage 400 V 200 ms[Ui] rated insulation voltage 400 V AC[Uimp] rated impulse withstand voltage 4 kV conforming to IEC 60898-1contact position indicator Yescontrol type Togglelocal signalling ON, OFF, fault tripmounting mode Clip-onmounting support DIN railcolour Whitemechanical durability 20000 cycleselectrical durability 10000 cycles 230 V AC 50 Hz conforming to EN 60898overvoltage category IIIcable entry Topconnections - terminals Tunnel type terminal for 1 cable(s) 10 mm² flexibleTunnel type terminal for 2 cable(s) 2.5 mm² flexibleTunnel type terminal for 1 cable(s) 16 mm² rigidTunnel type terminal for 2 cable(s) 2.5 mm² rigidwire stripping length 14 mmtightening torque 2 N.mcomb busbar and distribution block compatibility ProDisLibrio9 mm pitches 4height 81 mmwidth 36 mmdepth 72 mmnet weight 190 gEnvironment heat dissipation 7.24 W at 230 V - 25 AIP degree of protection IP20pollution degree 2tropicalisation Severity B conforming to IEC 60068-2-30 for 28 doperating altitude 2000 mambient air temperature for operation -25…60 °Cambient air temperature for storage -40…85 °Cproduct certifications RCMOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your informationEnvironmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins -
View more
Documents
Language- All Languages7
- English7
- Chinese2
- Czech2
- Dutch2
- Finnish2
- French3
- German2
- Hungarian2
- Italian2
- Norwegian2
- Polish2
- Romanian2
- Russian2
- Slovak2
- Spanish2
- Swedish2
CADFormatSizeAdd to My DocumentsiDPN N Arc 1P-N 6A...25A C 6000A Arc fault detection circuit breaker (Version 1.0)Files in documentSize zipSize 1.4 MBDate 11/24/15Files in documentCertificateFormatSizeAdd to My DocumentsInstruction sheetFormatSizeAdd to My DocumentsChina RoHS declarationFormatSizeAdd to My DocumentsActi 9 - iDPN N Arc - 1P+N 25A C 6000A - Arc fault detection circuit breakerDescriptionActi 9 - iDPN N Arc - 1P+N 25A C 6000A - Arc fault detection circuit breakerSize pdfSize 195.3 KBDate 12/10/19DescriptionActi 9 - iDPN N Arc - 1P+N 25A C 6000A - Arc fault detection circuit breakerDeclaration of conformityFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsActi 9 - iDPN N Arc - 1P+N 25A C 6000A - Arc fault detection circuit breakerDescriptionActi 9 - iDPN N Arc - 1P+N 25A C 6000A - Arc fault detection circuit breakerSize pdfSize 195.3 KBDate 12/10/19DescriptionActi 9 - iDPN N Arc - 1P+N 25A C 6000A - Arc fault detection circuit breakerREACh DeclarationFormatSizeAdd to My DocumentsActi 9 - iDPN N Arc - 1P+N 25A C 6000A - Arc fault detection circuit breakerDescriptionActi 9 - iDPN N Arc - 1P+N 25A C 6000A - Arc fault detection circuit breakerSize pdfSize 195.3 KBDate 12/10/19DescriptionActi 9 - iDPN N Arc - 1P+N 25A C 6000A - Arc fault detection circuit breaker -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.