Welcome to the Schneider Electric corporate Website

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   Acti 9 iEM2000
Schneider Electric A9MEM2150 Image

A9MEM2150

Schneider Electric A9MEM2150 Image
A9MEM2150

modular single phase power meter iEM2150 - 230V - 63A with comm Modbus

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range
    Acti 9
    family
    Acti 9 iEM2100
    device short name
    IEM2150
    product or component type
    Energy meter
    Complementary
    poles description
    1P + N
    type of measurement
    Active and reactive energy
    Active and reactive power
    Current
    Voltage
    metering type
    Active, reactive, apparent energy (signed, four quadrant)
    device application
    Sub billing
    Partial meter
    accuracy class
    Class 1 active energy conforming to IEC 62053-21
    Class 2 reactive energy conforming to IEC 62053-23
    Input type
    Direct input
    Rated current
    63 A
    rated voltage
    230 V +/- 20 %
    network frequency
    50 Hz
    60 Hz
    frequency measurement range
    45…65 Hz
    technology type
    Electronic
    display type
    LCD display
    sampling rate
    32 samples/cycle
    measurement current
    0…63 A
    display digits
    8
    maximum value measured
    999999.99 kWh
    Tariff input
    Tariff (1)
    communication port protocol
    Modbus RTU at 1.2, 2.4, 4.8, 9.6, 19.2 and 38.4 kbauds even/odd or none - 3 wires, insulation 4000 V
    communication port support
    Screw terminals: RS485
    local signalling
    Red LED: accuracy checking 1...1000 p/kWh
    Digital inputs
    0
    Digital outputs
    0
    Supply voltage
    96...276 V AC 50 Hz
    maximum power consumption in VA
    2 VA
    maximum power consumption in W
    1 W
    [Uimp] rated impulse withstand voltage
    6 kV 1.2/50 µs
    mounting mode
    Clip-on
    mounting support
    DIN rail
    connections - terminals
    Power circuit: tunnel type terminals (bottom) 1 1.65…33 mm² cable(s) solid
    Power circuit: tunnel type terminals (bottom) 1 1.65…33 mm² cable(s) stranded with cable end
    Communication: screw clamp terminals (top) 1 1…4 mm² cable(s) solid
    Communication: screw clamp terminals (top) 1 1…2.5 mm² cable(s) stranded with cable end
    tightening torque
    Power circuit: 2 N.m PZ2 screwdriver
    Communication: 0.5 N.m3.5 mm
    wire stripping length
    Power circuit: 17 mm
    Communication: 7 mm
    standards
    IEC 62052-31
    IEC 62053-21
    IEC 62053-23
    IEC 62052-11
    product certifications
    CE
    Environment
    IP degree of protection
    IP20 conforming to IEC 60529
    overvoltage category
    III
    pollution degree
    2
    flame retardance
    V0 conforming to UL 94
    ambient air temperature for operation
    -25…55 °C
    ambient air temperature for storage
    -25…70 °C
    relative humidity
    0…95 %
    colour
    White
    9 mm pitches
    4
    width
    36 mm
    height
    90 mm
    depth
    64 mm
    net weight
    0.175 kg
    Packing Units
    Package 1 Weight
    220 g
    Package 2 Weight
    6.835 kg
    Offer Sustainability
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
  • View more
    View less

    Documents

    Language
    • All Languages13
    • English10
    • French2
    • German2
    • Italian2
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    PowerLogic Catalog - 247 pages Web (NO PRINTED VERSION AVAILABLE) (Version 8.6)
    Description
    Note that no printed catalogs are available but all necessary source files, in 13 sections, are available for download from the Shopping Kiosk.
    prp.document.label.format pdf
    Size 14.8 MB
    Date 8/27/20
    Description
    Note that no printed catalogs are available but all necessary source files, in 13 sections, are available for download from the Shopping Kiosk.
    User guide
    Format
    Size
    Date
    Add to My Documents
    iEM2100 series user manual (Version 00)
    Description
    iEM2100 series Energy meters User manual
    prp.document.label.format pdf
    Size 633.9 KB
    Date 5/1/15
    Description
    iEM2100 series Energy meters User manual
    prp.document.label.format pdf
    Size 625.7 KB
    Date 5/1/15
    prp.document.label.format pdf
    Size 627.4 KB
    Date 5/1/15
    prp.document.label.format pdf
    Size 619.8 KB
    Date 5/1/15
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    iEM2100 series 63 A direct connect watt-hour meter (Version 00)
    Description
    iEM2100 series 63 A direct connect watt-hour meter
    prp.document.label.format pdf
    Size 1.4 MB
    Date 3/31/15
    Description
    iEM2100 series 63 A direct connect watt-hour meter
    Application solutions
    Format
    Size
    Date
    Add to My Documents
    Connect switchboards for electricalmonitoring and control (Version 3.0)
    Description
    Discover solution to:- identify origin of trouble in case of network issues, and return to service faster to minimize downtime,- remotely control electrical circuits,- engage preventive maintenance.
    prp.document.label.format pdf
    Size 431.7 KB
    Date 10/7/20
    Description
    Discover solution to:- identify origin of trouble in case of network issues, and return to service faster to minimize downtime,- remotely control electrical circuits,- engage preventive maintenance.
    Upgrade switchboards and convert them to digital (Version 4.0)
    Description
    Discover solution to:- understand better the energy consumptions and waste,- engage preventive maintenance,- identify origin of trouble in case of network failure, and return to service faster to minimize downtime.
    prp.document.label.format pdf
    Size 350.9 KB
    Date 10/7/20
    Description
    Discover solution to:- understand better the energy consumptions and waste,- engage preventive maintenance,- identify origin of trouble in case of network failure, and return to service faster to minimize downtime.
    Design new building with improvedelectrical efficiency (Version 3.0)
    Description
    Discover solution to:- comply to new energy management standards and better understand the energy consumptions and waste,- engage preventive maintenance,- identify origin of trouble in case of network issues, and return to service faster to minimize downtime.
    prp.document.label.format pdf
    Size 312.3 KB
    Date 10/7/20
    Description
    Discover solution to:- comply to new energy management standards and better understand the energy consumptions and waste,- engage preventive maintenance,- identify origin of trouble in case of network issues, and return to service faster to minimize downtime.
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    A9MEM2150 : modular single phase power meter iEM2150 - 230V - 63A with comm Modbus
    Description
    modular single phase power meter iEM2150 - 230V - 63A with comm Modbus
    prp.document.label.format pdf
    Size 195.3 KB
    Date 12/3/20
    Description
    modular single phase power meter iEM2150 - 230V - 63A with comm Modbus
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 113.2 KB
    Date 7/26/19
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    A9MEM2150 : modular single phase power meter iEM2150 - 230V - 63A with comm Modbus
    Description
    modular single phase power meter iEM2150 - 230V - 63A with comm Modbus
    prp.document.label.format pdf
    Size 195.3 KB
    Date 12/3/20
    Description
    modular single phase power meter iEM2150 - 230V - 63A with comm Modbus
    Technical leaflet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 347 KB
    Date 5/29/18
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.